Naren 3 Phase Digital Starter Model DOLDS (Kannada Version)

Поделиться
HTML-код
  • Опубликовано: 18 окт 2024
  • This video explains the features, settings, connections and operation of Naren 3 Phase Digital Starter Model DOLDS Type LTMU1. This Starter is a DOL type starter available from 3HP to 7.5HP and 10HP Submersible Pumps.
    This has built in Overload, Dry Run and Single Phase Protection along with 3 Phase Ammeter and Voltmeter with Trip Display and Trip Current Indication.
    There are 5 types of this Starter based on the different Contactors used
    Type LTMU1 - LTLK MU1 Contactor
    Type LTMK1 - LTLK MK1 Contactor
    Type BCH - BCH 4 Pole Contactor
    Type N-CH - Naren make CH type Contactor
    Type N-MK1 - Naren Make ML1 Type Contactor
    Please contact us for further details on
    9972243774
    www.narenelectrix.in

Комментарии • 24

  • @girimshetty
    @girimshetty Год назад +1

    nice explanaion

  • @shanumanthagonal9237
    @shanumanthagonal9237 Год назад +1

    Good tq sir🤝

  • @arjunjangid9056
    @arjunjangid9056 8 месяцев назад

    Does it records total power consumption? Or daily basis?

  • @sureshi1929
    @sureshi1929 Год назад

    For 2hp, 3phase it can be work

  • @SUNELECTRICAL
    @SUNELECTRICAL 4 года назад +1

    super sir #SUNELECTRICAL

  • @srikantan4746
    @srikantan4746 3 года назад +1

    Good

  • @vinayn2176
    @vinayn2176 3 года назад +1

    How does auto start work in dry run and over load situation?
    Auto start keeps starting motor again after dry run OFF and it's endless loop (dead lock).
    You should provide timer delay ( to be set manually) which waits for that time after dry run and over load and later after the delay it again should try to start motor using auto start.

    • @narenelectrixcompany6124
      @narenelectrixcompany6124  3 года назад

      Sir, the auto start works in the other manner. It just presses and holds the ON push button for 5 seconds. Hence, the motor then continues to run with the help of holding Contactor. Hence, in case of error, the motor will be turned OFF.
      Again after the power supply is resumed, the auto start again turns ON the motor (pressing the button for 5 seconds). In this case the holding contact (which is connected through the MPR) holds only if the error condition is cleared else will be open thereby not allowing the motor to run.
      Hence, there won’t be any dead lock situation. Hope your question is answered. Please feel free to contact us if you still have doubts regarding this. Thanks.

    • @sureshi1929
      @sureshi1929 Год назад

      For 2hp, 3phase it will work

  • @deepakmanagoli
    @deepakmanagoli 2 месяца назад

    Please show the one phase 180 220volts

  • @aziz0713
    @aziz0713 5 лет назад

    Hi sir DOLDS ch starter me cyclic timer kise jode Naren is best

  • @vishwanathgoudasandimani3367
    @vishwanathgoudasandimani3367 3 года назад

    Sir its start single phase & 3 phase dono

  • @Jaganown
    @Jaganown 2 года назад

    Sir 7.5 hp panel price allee

  • @nandeeshamrnandi4493
    @nandeeshamrnandi4493 3 года назад

    sri price yast

  • @srikantan4746
    @srikantan4746 3 года назад

    Sir 5HP CRI PUMP STARTER PRICE

  • @pradeepkumarkr7688
    @pradeepkumarkr7688 4 года назад

    ಅಮೌಂಟ್ ಎಷ್ಟು