Affordable Solar Setup: Reusing Desi UPS and Sinko 65A MPPT
HTML-код
- Опубликовано: 28 май 2024
- Hi everyone! I hope you’re finding my videos on solar setups, DIY projects, and electric tips helpful and informative. If you've learned something new or simply enjoy the content, consider supporting the channel. Your generous contributions help me create more videos and bring you the best in electric and solar knowledge.
Buy Solar panels cleaning kit
s.daraz.pk/s.YjWG?cc
Visit Our Website 🌐 For More Information and Product Details: www.toorelectric.com/
Send a Tip 💸: [0303-8086698 Jazzcash/Easypaisa ]
Every little bit helps and is greatly appreciated. Thank you for being a part of the Toor Electric community!
Stay charged and keep exploring! ⚡️🔋
.
. Website: www.toorelectric.com/
In this video, I demonstrate how to set up an efficient solar power system using an old Desi UPS and two Jinko N-Type 580W solar panels, integrated with a Sinko MPPT 65A charge controller. Follow along as I guide you through the process of upgrading your power setup, utilizing affordable and accessible components.
In this video, you'll learn:
1. How to repurpose an old Desi UPS for solar power
2. Step-by-step installation of Jinko N-Type 580W solar panels
3. Integration with a Sinko MPPT 65A charge controller
4. Tips and tricks for optimizing your solar power system
Whether you're a DIY enthusiast or looking for a cost-effective solar solution, this tutorial will help you harness the power of the sun with minimal investment. Don’t forget to like, subscribe, and share if you found this video helpful!
Materials Used:
• Old Desi UPS
• 2 Jinko N-Type 580W Solar Panels
• Sinko MPPT 65A Charge Controller
Visit toorelectric.com for interesting products.
بہت نفاست سے کام کیا ہے آپ نے
Jazak Allah brother
Bhai jan Masha Allah apki videos bht interesting hain
Jazak Allah
*1:25** Series main plates laganay per ampere increase hotay hain volts nahi. MPPT controller khud ampere control karkay batteries ko charge karta hai or Solar say direct power bhi aagay dayta hai. Sham hotay hi hybrid MTTP Solar say auto switch karkay battery per chala jayega or UPS battery say power aagay daygi. Plates kam houn to parallel lagatay hain zyada houn to series.*
Yh kis ny bol diya k series sy ampere zaida hoty hain
@@ToorElectric *Aap check karlo, aapko idea hojayega. Series main Ampere add hotay hain or parallel main Volts.*
Super video
So many thanks
So nice of you
Welldone. Zabardast video
Many many thanks
V good explanation. It is cheapest system.
Thanks
nice video .........should used Dc circuit breaker on Solar side and AC breaker on Grid or wapda site ...also SPD used to protect MPPT and other device ,,
Ok sir
Very good 👍
Thanks
Good work done bro
Thanks
A/a Bhai mane ap sentr se lete or behtreen hu jata,👍
Sorry m smjha nhj
Brother aap ne bohat acha samjhaya. Aap 10 kw ka system install karna b sikhain plz
8kw ki video upload kr chuka hu wo dekh lay
zabardast video
Thanks
Good job.
Thanks
Nice work
Thanks
Bhai 60amp ki mppt se direct dc load ki jaga 1000wat ka inerter laga kar led tv our receiver chala sakty hain
Masha Allah
Jazak Allah
Very good information of complete installation. Where do u reside gentleman. Appreciate.
Check description
Boss nice video
Thanks
Mere pass tx 1800 aur 80 amp sinko dc setup k lie ha. Float voltage company k rakhe han 13.5 volt aur bulk 14.6 volt but battery 13.5 se oper charge ni ho rahi. Sinko ma "full battery cut off ni ha" to full charge Phoneix tx 1800 tall tubular ko kaise karen. Mera day time mostly 7 ampere dc load hota ha aur kbi total 17 amp dc pump k sath. Please reply!
Mukmal db box ke connection ka tarika batay.thanks
Ok sir
Good
Thanks
Bahi aap ek galtee ki panal kit Watt ki lagayi.or kitnay fan light on ki.?
1kw
bhai iskay sath 3 panel lag saktay hai series may kya 550 ya 540 watt k or doosra pochna tha k ups square wave hota appliances jalayai ga to nhi hamari
G lag jygy series m
Panel connections series mein or ups single battery 12 volts...ye kese?
Agr ap ko mppt ki know how hogi to he ap smjh paygy
Brother meri pas Homex MPPT hy 70A or us ki Max-Voltage 95V hy to keya 2 panel of serial mi lagana teak rahi ga Jinko N Type 585 Watt ki pannels hy?
G laga skty hain series
Aslam o ailkum
Ap level or South check karty hain
Per tilt angel nai btaty
Next video sy wo b bata dygy brother
Bro mere pas simtek 65Ampere hy
Mene 2 panel lgane hen 580W ke
To solar panel series me Lgaen
Ya Phr paralell me
Simtek 65 ampere vala hy mppt
Series
MashAllha
Thanks
Solar se hum mppt k through AC bijli ly sakte Hai din k time without Wapda connection??
No it's just a battery charger
Asalam o alaikum ,Series conection main PWM controler use kr skty hain kea
No
Bhai mare pas homing ups ha battery 180 excited ha mazeed daball manzal house ha 7marla total karcha aur 5 impair Kafi please detal ma bata dn sukriya ❤
Sorry m apki bat smjh nhi saka
Bhi Jan is mppt ke sath tubler battery install kar saktey Hain
Yes
Meray pas china ka ups h 1kva ka purana model h
Ups running ma h ..
2 550w k panel k sath mppt lga k setup pa max kitna load chala skta hn..
Me ya b suna h k desi ups zyada achay sa load chalatay china ups ki nisbat
R mera ups h b china r purana b kafi h
To just doubt clear krna h k kitnay watt load dalon
500/600/800 watt..
Taa k system proper working ma rahay
600 700 tak chla lay but best hai k inverter ly ly agr apka ups old hai to
@@ToorElectric thanks.
brother agar solar kay conection peralal m krain to phir bhi kam kray ga mppt kia
Mppt ki input pv k ampere dekh ly agr wo 26 sy zaida hu to ap parallel b kr skty hain
AOA.
Bjai mere pas 2 585 walay panel hen aor aik Simple Sinowave 1000 watt ka UPS he aor 70 ampare simtek hybrid mppt controller he aor is k sath two 200ah and 100 AH ki batteries hen. Kia men panell serires men lagaon ya parallel. Merai pas just 4 AC DC fan hen aor 4 LED hen
Sor ye bi bataen k .kia men sath men inverter fridge chala sakta hon. Men ne wesay ups per fridge check kia tha wo 200 watt load show kata he ups per.
Kindly rehnumai farmaen
Agr apka ups fridge ka laod uthata hain to chla lay aur pannel k connection mppt ki range k mutabiq kry
Kia 2 mppt controller aik hibattery k sath connect ho saktay hain
Battery sy konsi dushmani ka badla lena?
Ab is Mppt ki price Kia hy
Same setup mn na bhe lagiya ha but mry case mn simteck ka mppt ha aur homage ka inverter but monthly end pa koi savings nhi hoti ha bus ya faida ha ka load-shading sa jan chot gai
Iss system sy bill py bhout zaida farak nazr nhi ayga just load sheading m sakoon mil skta. Inn dino wsy b bijli k bill increase howy hain
@@ToorElectric Kia battery bank increase krny sa koi benifits ho skta ha bill reduced mn
Yes phr sari raat apka ups backup mode m chlyga lkn apko apky simtek ko wapda off rkhna hogi
@@ToorElectric ap Lahore mn installation ki service provider kr skty ho 580 watt ka 8 panel with inverix inverter ?
Yes we can
Hybrid mppt ki bri khami ye hy k jb sun nikalta hy & aser ko down hota tu asa system switching krta rehta hy isliy behter hy non hybrid mppt lga kr subo & sham ko ek on off button ko istemal kia jy price ki bi bachat oar kaam bi tension free
Brother yh sinko Wala switching nhi krta bar bar
@@ToorElectric پلیز پرائس بتا دیں پھر اگر switching نہیں کرتا تو،،، دوسرا یہ کہ کہاں سے پرچیز کیا جائے پلیز
Aoa mery pas 24 volts ka 1 kw ka solar inverter he jis ke capacity 24 se 45 volts aur 60 amp current he. Kis is k sath 585 watts ke 2 panels parallel lag sakty hn. Plz reply
Please contact on WhatsApp and send data sheet
WhatsApp number please @@ToorElectric
Assalam o alaikum, plz jawab daina
mere pass homage 750 watt ups or 190 amp battery install hy ,
Guide me konsa panel or konsa mppt hybrid purchase kro ,gudd result k lye trouble free ho ,kindly jawab day dain,
Yhe system apky liya best ha video wala
Brother agr fridge chlani ho 2 570watt n type pr mppt 100a sim tech hybird to chal jaye gi? How? Plz must tell
Fridge apky ups py depend hai k wo uska load uthyga k nhi
@@ToorElectric bhai jaan 1200 watt ups ha. Fridge k pichy normal input 150-470w likhi hui. Plz guide me
@@Brotherology1234brother pehla tark jo hota ha wo bohat havy hota ha is liye ups use nhi chala sakta behter ha k ap koi bijli wala LA kr ay or use boly k refrigerator k wir k sath ampere meter lga k dakhy k jb start hoti ha to kitne ampere Lati ha wo bijli wala hi apko bta dy ga.
Ir
Is tar ki jga àap 2 kor silwar me bhi istmal kr sakte he ?
Wire hansha copper ki use kry
Main energy mppt use kr rha hon 70amp ka 110AH ki battery ha dc load chalta ha 20-25 amp ka, mppt 1 min main battery ko charge krta ha battery full charge k bad cut off ho jati ha usky baad load pwm-battery sy chalta ha kuch 2-3 mins battery low hoti ha toh mppt dobara chal jata ha aur sara din aesy hi hota rehta ha.
Mere is setup main kia masla ho sakta ha. aur kia main mppt beghair battery k chala sakta hon?
Contact on WhatsApp
Sinko Mppt 80 amp wla m 3 panal add ho sakta ha 585 watt wala
Yes
Bhai jan ye btao k agar parallel mei connect kare 2 plate k liye tho koe nuksan hoga ya kya ho jata hai plz ?????😢
Mppt ki range k mutabiq connection krny hoty hain mery case m yh series hota ha
Bhai fan ac dc lagana pare ya ac b chale ge din me
2no chl jyga
Kaya sir esa hu skta hai ke hybrid mppt ko sirf ma solor aur bettrey charge ke lay used ko suba ke time aur sham ko ma kud usp ke zrry wapda on kr do ta ke ups sa bettrey charge hu gy! Mutbal ma hybrid mppt ko usp ke wire aur wapda ka connection ni dehna chata ma kud wapda ko on off kr ke bettrey ko charger krna chta hu
G bilkul ap aisy kr skty hain
@@ToorElectric ku ke sir mujy lag rha hai ke mera mppt jo hai eo suba bhi solor aur wapda ko used kr rha hai is lay my suba mppt ko wapda ki supply ni dehna chahta sirf raat ko bettrey ko charge krna ke lay on kr diya kro ga
sir ek sawal hy meine bhi hybrid system lagana hy aisy he chota hy. sawal ye hy kay 580w ki agar 2 plates lagata hun to kya mery a/c fans 4 or ek fridge chal skta hy day or night.????
No
Fans chl jygy fridge agr inverter ha to chlygi wo b ups pr nhi solar inverter pr
Agar hamary paas u p s mojood naa ho to Kya battery ko raat k waqt charge karny k liye battery charger ka estemaal kar sakty hen.
G
Bahi Jan agar 2 penal paral may lagaie to lod Ka koi paraq parta hay
Series m he lagy agr same mppt use krhy hain to
Homage ups 700VA b is system me chl jai ga?
G chl jyga
Kya aise 2 panels pe fridge chala skte hai
Os k lyr aor kya requirements honge
Ups py fridge to mushkil sy chlygi mgr agr ap car inverter zaida watt ka ly k lagy to us py chl skti ha
@@ToorElectric kahate Hain ki car inverter jal jata hai inki life ni ha such ha
Aslamoalikum
Mera aik Question hai, mery pass faisal Mppt 65A hai
Kya mai us k sath 580w ki 2 plates lga skta ho parallel?
Uski datasheet check kry
Allha Moja b aysa system lagana ki tafeeq ata farma
Ameen
Brother ye Batyeen jub Solar say PV Arahy hain apkay to tab Utility ki light kun On ha ??
PV off the because of night
Battery se nahi matlab mppt k load wali jaga se inverter laga kar ac load kitna chala sakty hain
Without battery nhi
Without battery ka nahi keh rha bhai Jan mn battery sath lagi hui ka keh rha hn dc load wali jaga se
585W double glass waly 2 panels laga sakty hain series main? 70Amp k energy Mppt k Sath?
Series
@@ToorElectric Sorry sir sumjha nhe laga sakty hain k nhe ?
Nai lga sakty Energy ka Jo mppt h us ki p.v range 100vdc hoti Hy
Bhai Jan is trah ka Purana ik khrab ups hmary pas hy Kia wo thk ho skta hy
Pas ksii repairing dokan sy pta kry
Bhai main jab wapda currant band karta hoon to aik ganty k bad ups band ho jata hai, merbani Kar k ranomai Kar din
Battery backup khrab hai apka
2 penal 585 par 3 kv inverter sy kiya chlyga
Fan + lights + inverter fridge
Battery volt 13.1 q hai ... Full battery volt kitna hota hau at rest
Battery 14.5 pr full hoti ha
Bhai maray 6 kW kay panel lagay huway hain lakin inverter pay 500 watt Arahay hotay hai koi bata sakta hai problem kiya hai
Jitna load ap daly gy inverter pr utny watts bnygy
Salam bahi Jan is mppt par car inverter kasy use kryn Raat ko ??
Battery k sath car inverter laga k us m sy load ly skty hain
bhai ek question hai, mre pas abhi desi ups 70 AH ki battery ki sath laga hai, battery jab charge hojati hai to us k baad jo bhi load chalta hai to wo shaed ups direct chalata hai kyon k battery garam ni hoti phr.
mra ye question hai kia MPPT bhi esy hi krta hai? mtlb agr ham MPPT se battery full charge karlen or phr load chalaen battery k sath to kia mppt direct power dega load ko ya battery k through aegi ? agr battery k through aegi to isse battery continuous charge discharge se jaldi kharab ni hojaegi ?
or ek or question hai mre k hybrid mppt work kese krta hai ? agr badal hon or solar for eg 100 watt banara ho khali or ham ne load battery per 300 watt dala hai to mppt kab solar se wapda per shift hoga, or phr waps dhoop nikal ati hai to waps kab solar per shift hoga ?
Already reply kr chuka hu whatapp pr
@@ToorElectric shukriya
@@ToorElectrictoor bahi mje bhi btaa den same question
bhai jan aik 12v 100amp DC relay laga lu ? mene 5 rooms me aik aik fan or aik dc light use karni hai dc ki is k elava DC MOTOR ko b connection dena hai
KIA me 100amp ki aik relay se out put me alag alag wires . rooms k lia le ja sakta hon ya zeyada RELAYS lagni hain ?
100amp SIMTEK + 2 panels 585watts
4 ac dc 12v fan load....6 bulb 12v or kabi kabi 12v DC water pump
G aik he relay sy hojyga apka kam ap lga skty hain
Aslam o alikum, hyd me service dete he ap?
Wa Alikum Salam no
Desi 1000 watts ups per ak wakt main kitna load chal sakta hy please inform ..electrician ny btaya hy 650 watts tk load chal skta hy
Wo to apky ups k circuit py depend krta but zaida tar ups 700 800 tak load chla paty hain apni peak capacity py
Assalam u Alekum bhai ye Jo MPPT sinko ki price keya hai?
25500
Ak fige aur ak pankha chalana hu tu kitna panel lagain ga ups aur mppt ka sath
Phly check kry ups apka fridge chlyga b k nhi
Do 585 penal aur 3000 wala inverter frige motor ya istree koi b ek waqt chalaega ؟؟
Battery rat ko wapda sy charge krny ka kia faida
Agr raat m battery low hojy to tab k liya
Mery pas himo ki 6 plates hain ...series main lgaon ya parallel...koi bta skta hy plz
Depends on k attach kisky sath krny hain
Mere pas 1000watt ups 175 Ags betry 2 panel lgana chah rha plz guide krdo
China type, kit Base ups py yeh setup kaamyab nhi?
Laga skty hain ap already iski video upload kr chuka hu
apki service karachi mai available hai kya ?
No
Bhai battery kysath breaker kyon ni lgaya
Taa k koi solar ko on rhty howy battery breaker na off krdy aur mppt na khrab hojy because wo without battery kam nhi krta
Aap kon se shehr main hoty hain
Narowal
agar humen freezer chalana ho to kitne panel use honge
Check freezer ampere first
@@ToorElectricwo kasay kra ga check
App totally package ka kam Kerry hann ?
Main b same system LA ga na ha
Location?
Sir
Arifwala...city
@@ToorElectric
Arifwala city
Total load ktna atata max sirf solar pr????
Load apky ups pr depend krta
Bahie is setup per kitna kharcha ayega
Watch video end
Bhai ap kis city say hain plz btaien
Narowal
Cost b btaya kerain bhya
Last py btye hai
Battery wire price please?
200 per ft
Window ac kitni plates p chla sktay
Ampere check kiya bgair batna mushkil ha
@@ToorElectricjazakillah
0.50 ton ka AC?@@ToorElectric
Bhai kis city see hoo
Narowal
big matter battery who expire in one year
Sorry I can't understand
Bhai lahore mai system install kr do ge?
Yes
@@ToorElectric bhai contact no. & charges for installation of mppt, car inverter with 2 plates?
mppt or inverter aik hota?
No
Total kitna kharcha
Video ka last check kry udr sary rates baty hain
Is Mppt ki price Kia hy
Latest prices k liya market visit kry
Kitny ka liya hy sinko
25500
Bhai same yehi setup meny ghr py lgaya hy double battery per , Soler sy 20 amp arhy hain jis sy battery heat ho jati hy , iska koi solution btaiñ Battery 130AH ki hy
Ap ny Bulk Voltage kitny set keay huay hain or Float Voltage kitny py rakhy hain ???
Bhai esa makn ny bhi kya hai. Betrry heat ho rahi hai waja kya hai. 14.5 volt py jata hai bas
Mppt konsa use krhy ho?
Ulta bata gae hain janab.
Amp increase hoon ge voltage increase nae hoon ge ye kehna tha 1:29
Check me check
Brother m ny thk bola ha apko confusion hai koi maybe
serires main volt increase hotay hain paralal main amp ok
L-2 stand 4500 ka he 6000 ka nae he.
Konsi jaga
Wire total loose gauge ha
Ok sir
Is py kitna kharcha aya ha
Watch video till end
Jab Battery full charge ho jaye gi tu iss ko cut off kerne ke liye pwm charge controller nahi lagaya, full charge per battery ko cut off nahi kiya tu battery kharab ho sakti hai
Mppt khud cutoff kr skta ha pwm ki zarrort nhi hoti ac setup m
MPPT voltage ki reading krta rhta hy
Bulk Charge ka matlb k battery ko MPPT charge hony k 2ran kitny voltage dy rha hy
Or
Float charge ka matlb yh hy k 1 bar battery full charge ho gai hy to
Charger kitny voltage berqarar rakhy takeh battery down na ho
Agar DC setup ho tu phir Kiya hoga
@@tehminazaib3747
DC ho to b same
Q k MPPT battery ko deal krta hy
Agr ap load py PMW lgana chahain vo b option hy
MPPT battery charging k leay
PWM load chlanay k leay
Thanks for reply
Kis city se ho ap ?
Narowal
Bhai jan MPPT to apnay 25 hazar ka bataya hai but ziyada tar log to 12 hazar waly latay hai ?
Sasta b mil jta
12 hazar Wala simple hai hybird NH hote