RH % Control with Dew Point || HVAC Tamil || Ravi Shankar ||

Поделиться
HTML-код
  • Опубликовано: 19 окт 2024

Комментарии • 28

  • @PremKumar-sm1tk
    @PremKumar-sm1tk 2 года назад +1

    Very informative bri

  • @PremKumar-sm1tk
    @PremKumar-sm1tk 2 года назад +1

    Looking smart fit bro 👍 good keep it up

  • @pandiyanpandiyan4771
    @pandiyanpandiyan4771 2 года назад +2

    Very good sir

  • @prakashksp2918
    @prakashksp2918 7 месяцев назад

    Good explanation

  • @kulothungan1994
    @kulothungan1994 2 года назад +1

    very helpful video thanks bro

  • @abhilashac3988
    @abhilashac3988 23 дня назад

    Sir very good.. Plzz explain its controls also

  • @jagadeeshjagan9743
    @jagadeeshjagan9743 2 года назад

    Nice Explanation bro.

  • @vinithjohnson7320
    @vinithjohnson7320 2 года назад

    Thanks anna for accepting my request💕

  • @sundarnaga5847
    @sundarnaga5847 2 года назад +1

    Hi anna, your videos are very helpful for me , I have a doubt - I observed one site they have the MAU & they treated fresh air and directly connected to the FCU - Supply Duct.
    Is this Correct - Bcoz usually Fresh air will be connected to the Return side of the Unit. However we also obtain the High Humidity level .How we control the Humidity

    • @lohisya_media
      @lohisya_media  2 года назад

      MAU delivery will be connect in FCU suction then only we can achieve humidity
      Other wise reduce MAU air flow and reduce set point of MAU chilled water temperature

  • @sakthivela5557
    @sakthivela5557 Год назад

    Sir,
    100% means it's complete water vapour right?
    It must be below 100% RH.
    Please correct me if I'm wrong...

  • @shivask5982
    @shivask5982 2 года назад

    First of all Thanks for your wonderful video. it is very useful Sir 🤝👍👏
    My question related to RH is when
    Return Air Temperature is 36
    Supply Air Temperature is 20
    Delta T is 16 ( No fresh air in take )
    When the Delta T is more RH is going below requirement
    When the Delta T is less RH is going Above requirement
    Is there is any relation between Delta T and RHa

  • @sureshd2095
    @sureshd2095 2 года назад

    Thanks bro! Can you also explain new technology in Cleanroom that uses MAU and Dry coil unit to maintain Space RH and Space Temp

  • @Babujay16
    @Babujay16 2 года назад

    Thank you brother AHU Designing videos poda mudiyuma

  • @arunkumarm274
    @arunkumarm274 2 года назад

    Hi bro ahu bleed air pathi explain pannunga please

  • @Sankar_san95
    @Sankar_san95 2 года назад

    How to select hvac for cleanroom ? How to calculate require cfm? How to find require supply grills?

  • @venkatesanm2563
    @venkatesanm2563 2 года назад

    Bro That Heating Coil Used for UV Coils ?

  • @arun4846
    @arun4846 2 года назад

    Thanks Anna ❤️❤️❤️

  • @vijaychrist211
    @vijaychrist211 2 года назад

    Need .Mechanical video air winch

  • @kulothungan1994
    @kulothungan1994 2 года назад

    bro air balancing pathi video podunka

  • @massasan610
    @massasan610 2 года назад

    Bro motor connection pathi solu ga bro

  • @nampurajan414
    @nampurajan414 Год назад

    Sir DPH and DPC details

  • @yogeshkumarpm7994
    @yogeshkumarpm7994 2 года назад

    ❤️❤️❤️❤️

  • @thirumalaisubramaniyan8964
    @thirumalaisubramaniyan8964 2 года назад

    Hi anna,Trane chiller pathi solluga anna

  • @thangamvetriselvan1889
    @thangamvetriselvan1889 2 года назад

    Black smock control