Water Hammer Simulation with OLGA, OLGA tutorial 7

Поделиться
HTML-код
  • Опубликовано: 17 сен 2024
  • In this tutorial you will see how to simulate a water hammer problem and how to set the integration time and calculate the valve closing time in order to capture the water hammer phenomenon correctly

Комментарии • 21

  • @osma2027
    @osma2027 Месяц назад

    Please come back and do some more dynamic scenarios analysis using OLGA , shutdown , restart , turndown , ramp up , pigging , black startup , normal start up , and most importantly pressure surge analysis for oil and gas systems (valve closure, Pump start up and shutdown) it would be a great addition to the already great OLGA library you have

  • @breedib
    @breedib 6 лет назад +1

    Great work !

  • @philippebehe448
    @philippebehe448 5 лет назад

    Thank you very much for sharing this. Have you ever tried to simulate water hammer occurring on a check valve (a "non-return" valve)? I mean when the valve is shut by the fluid itself, preventing its backflow in a circuit that is meant to be unidirectional ? Can you point out why such design are particularly prone to generate water hammer? Thank you

  • @gopivairam3957
    @gopivairam3957 5 лет назад

    Hi Mr. Hatef, thanks for sharing your knowledge. It is very useful. I try the same model but with minor changes. I keep the valve at the middle of pipeline. The model does not converge and it gives error as "pressure below Table values -0.084 bar". How to solve this error. In PVTSim we can not generate fluid table below 0.001 bar. Kindly give me your advice to solve the error.

  • @ayomideadekoya8879
    @ayomideadekoya8879 2 года назад

    Thank you very much, very enlightening. Please can you provide the data files used in this exercise.

  • @rezaajib3707
    @rezaajib3707 5 лет назад

    Very good

  • @tunisiano3236
    @tunisiano3236 4 года назад

    hello, great job
    one question: starting from 11.08 sec you have used the mouse in order show the pressure profile vs time, in my duplication i cannot do this , the time goes directly from 0 sec up to 20 secds!! how to fix this?
    thx

  • @Faiz-xu6yk
    @Faiz-xu6yk 2 года назад

    Thank you for sharing. May you share how you make water tab and only compo H20 using PVTsim?

    • @seshu1353
      @seshu1353 Год назад

      did he share with you ?

  • @restdeepak
    @restdeepak 5 лет назад

    Great Work, can you please upload a few videos on how to create tab files using PVTsim. It would be grateful if you would also share the tab file. Thanks

  • @avatar_kyle
    @avatar_kyle 6 лет назад

    Hi Hatef,
    My senior project group at LSU is utilizing OLGA software for our project. We are trying to perform a water hammer simulation similar to yours, but we keep getting an error saying "Pressure in Node-1 above pressure range". Do you have any insight as to how we can go about changing a pressure range?
    Thanks for all the tutorials, and I know the question might be vague, but we appreciate any help.

    • @archivehakh
      @archivehakh 6 лет назад +1

      Kyle Beckert Hi Kyle. Increase you pressure range in your tab file. This might help to get rid of the error

  • @sidaiuodaosdo5035
    @sidaiuodaosdo5035 5 лет назад

    ThNK U

  • @nourelislamlounis3328
    @nourelislamlounis3328 4 года назад

    thx aloooot

  • @breedib
    @breedib 6 лет назад

    can you help me with this tutorial? i have to do a project with water hammer phenomena

    • @HatefKhaledi
      @HatefKhaledi  6 лет назад

      How can I help you sir? Please explain your problem and your question

    • @emadelgebesy6731
      @emadelgebesy6731 5 лет назад

      Better to use PIPENET as a specialist software in pressure surge. OLGA's result for pressure surge is not up to scale.

  • @breedib
    @breedib 6 лет назад

    can i have your contact, email or everything else?