ILLUSTRATION AND TESTING OF STAIRWELL PRESSURIZATION AND SMOKE CONTROL SYSTEM

Поделиться
HTML-код
  • Опубликовано: 21 ноя 2024

Комментарии • 26

  • @JoshuaDavid-w3g
    @JoshuaDavid-w3g 3 месяца назад

    Really helpful Arki. Thank You

  • @heilleocoopter8114
    @heilleocoopter8114 Год назад +1

    Really well presented sir. More power!

  • @likha360
    @likha360 Год назад +2

    Thank you Architect! Very useful info.

    • @arki-knows
      @arki-knows  Год назад

      Thank You very much nakatulong in simple way.Regards😀

  • @mildredgolpeo6098
    @mildredgolpeo6098 Год назад +1

    Very informative 👍

  • @mildredgolpeo6098
    @mildredgolpeo6098 Год назад +1

    Wow ❤❤❤

  • @likha360
    @likha360 Год назад +1

    Method ng water supply distribution din sana for highrise building , cistern, type of pump ,for fire fighting etc. May basic knowledge nman ako pero theory lang. Mas maganda galing sa experienced person like you po . Aspiring architect plang po ako. 😁 Thank you.

    • @arki-knows
      @arki-knows  Год назад +1

      Yah, no worry.sure hopefully i can prepare and share as well about the system that you mentioned.😀Thanks for your suggestions.😀

  • @mariotagarro6069
    @mariotagarro6069 Год назад +1

    Tamslove po sir

  • @jaywar6347
    @jaywar6347 7 месяцев назад

    Arch, sana meron din video on how to get CFM for fresh and exhaust air Blowers.

  • @renemadriaga7041
    @renemadriaga7041 Год назад +1

    Sir ilang pascal yung pressure dapat para maipush yung pushbar ng fire exit door? At nakainterface po ba yung supply fan ng staircase pressurization unit sa fire alarm system? Thanks

    • @arki-knows
      @arki-knows  Год назад +1

      Hi!Sir,thanks for the comment.Regarding the pascal/pressure to push the panic device door.There was no indicated pressure indicated in the Fire Code of the Phils.nor in the NFPA -1 Fire Code 2018.But there was stated in NFPA.All fire doors shall be self-closing.They shall be permitted to remain open during normal operations if they are designed to close automatically in a fire emergency by means of listed closure devices.This means the panic door can be push without exerting much effort because the door can be automatically closed with the door closing devices fixed in the door.For the air pressurization for the fire exit.Yes, its interface with the fire protection system.In the case of fire.When the sprinkler or smoke detector triggered due to presence of fire the air pressurization will also be in operation when the fire and jockey pumps gives all signal to the system that there’s a presence of fire.This are all working as a team incorporating in the system to suppressed the presence of fire in the buildings.Hope i answered your inquiry.Regards

    • @renemadriaga7041
      @renemadriaga7041 Год назад +1

      @@arki-knows yes sir I understand that since there are different type of occupancies in a building, it might be children, elderlies so it is very important to note that the pushbar can be open by those category of individuals however it is also considered that even though the door is self closing it is in fact once the door is kept open for a certain period of time due to evacuees trying to evacuate the building it is very certain that there will be a pressure drop that needs to be compensated by the motor fan in order to maintain the required necessary pressure since we are dealing with the pressure difference betweeen the fire exit and from the outside of door to prevent smoke or fire from entering the fire exit door. Anyway thank you sir for the elaborative explanation.

    • @arki-knows
      @arki-knows  Год назад

      Thanks for the reply Sir.Concerning the children during emergency.Fire Exit doors panic device are user friendly and can be push immediate during emergency by a 7 or 8 yrs old children to vacate into safety using the fire exit doors.Now, during emergency,its still the elderly may direct all the children to safety and definitely in this case by their guidance they will guide children into safety by pushing the fire exit door panic device.

    • @heilleocoopter8114
      @heilleocoopter8114 Год назад

      Section 5-2.1.1 of the NFPA 101, Life Safety Code requires the door opening force in egress path to be limited or no more than 30 lb of force (133N), hence, stairwell pressure should be maintained around 25 Pa to 50 Pa

    • @arki-knows
      @arki-knows  2 месяца назад

      @@renemadriaga7041 1. Hello!Sir, just browsing our recent conversation on the force of push to apply to let the door open pushing the panic hardware . Based on RA 9514 The Fire Code of the Philippines under Section 10.2.5.3 DOORS letter F. PANIC HARDWARE : When a door is required to be equipped with panic hardware by some other provisions
      of this Rule, the panic hardware shall cause the door latch to release when a force of not more than seven kilogram-force (7 kgf) is applied to the releasing device in the direction of exit travel. Hope somehow our concern had been answered. Thank You. Stay safe.

  • @tariq1099
    @tariq1099 Год назад +1

    Why switching from English to a different language?????

  • @likha360
    @likha360 Год назад +1

    Architect yung smoke proof enclosure po ba bawal lagyan ng window? May nabasa kasi ako sa firecode dapat walang opening maliban sa self closing na door. Kung bawal po, pano yung lighting dyan? Artificial lang?

    • @arki-knows
      @arki-knows  Год назад +1

      Hi!Sir,Thanks for the inquiry.The enclosure ng pressurization and smoke control chase ay walang opening.Intended sya na enclosed wall and with fire resistive rating of 2 hrs.No windows and doors also.Every fire exit level.May stairwell pressurization louver sya or damper na naka concealed sa wall.Also wala rin syang lighting sa loob since totally enclosed wall sya dahil sya ang tutulong in the event of fire and located sya sa area ng fire exit stairwell.You may check yung isang content about How the Fire Exit Pressurization and Smoke Control System Works.You’ll see yung actual installed louver grille ng air passage ng ducting na nasa loob ng pipe chase.Hope the answer helps.Thank You😀

    • @likha360
      @likha360 Год назад +1

      @@arki-knows thank you architect..

    • @arki-knows
      @arki-knows  Год назад

      @@likha360 My pleasure😀Thank You as well.

  • @marcrovinmendoza4226
    @marcrovinmendoza4226 Год назад

    Same CFM po ba dapat yung capacity ng fresh air at exhaust?

  • @viveks2343
    @viveks2343 Год назад

    English please

  • @savadva
    @savadva Год назад

    Why you use Tagalog after a long well English verbal presentation 😮😮😢