अरे भाई NON INVERTER AC लेना चाहिए वह बढिया रहता है। उसमें out door में कोई PCB नही होतीहै मेने तो mitsubishi का 1 .6 टन का Ac लगवाया है। बहुत मस्त चल रहा है चार साल से सिर्फ सर्विस करवानी होतीहै साल में एक या दोबार 400 -500 रुपये लेता है टेक्नीशियन मामला चका चक
Sir, i would like to ask about the problem of the daikin multi split indoor unit working fine and not blinking but the outdoor compressor and fan are not working, the PCB is also problem ? i hope you can give me an explanation so that i can know about this knowledge, Thank you
Cancel button ko long press kro veep ki awaj ane tak fir cancel button ko bar bar press kro agar kise code pr long veep ki awaj aati hai wo code comment me type kro
@honeychahal9364 i did that and got U2 error. I have the same problem as that guy. I found the capacitor C85 has infinite resistance across it, could that be the issue?
bhai mne ek chij notice ki h ki daikin ke AC me minimum 2 rows ki to coil hoti hi hai....mere voltas ac me 1.5 rows h outdoor unit pe wo 3 star inverter h apka daikin 3 star h ya 5?
sir. mere ac me trip ki problem hai 3 4 second chal kar band ho jata hai out door. mai naya pcb lena chahta hoon. us kaha se magaen. aur kitna cost ayega. sir please bataye.
sir app error code check kro fir aap ko pata chl jaiga k kya problem hai agar outdoor cut kr raha hai ho sakta hai k pcb ki problem ho agar voltage proper na ho fir v cut kr jata hai ac
i have daikin split ac. Even room temprature is 29-30 when I set to 26 the compressor is not starting and it start if I lower to 24. I have already replaced the capacitor (outdoor) and temperature sensor(indoor circuit with sensor). Any suggestions? Aur error code 00 ata hai.
@@honeychahal9364 Sahi bat hai. Par room temprature 28 hota hai to b compressor chalu nahi hota hai. Aur 26 set karu to 1-2 min chalake trip ho jata hai.
sir abi jo mosam chl raha hai is me ac low temperature pr he compressor on krta hai abi rainy session chl raha hai 25-26 pr v compressor jyada nahii chlta jaldi trip kr jata hai aap k ac me koi problem nahii hai
@@honeychahal9364 sir spark hua tha outdoor unit me .... Technician ne bataya pcb me fault aaya h.... Repair waalo ne bola repair nahi ho payegi pcb..... Problem thi ki spark k baad se compressor 1-2 minute start hoke band hojaara tha.. aur fir 5 minute baad 1-2 minute k liye start horha hai...
sir voltage ki problem ho sakti hai agar voltage sahii hai fir pcb me problem ho sakti haiii aap error code check kr lo pata chl jaiga k kya problem haii
remote me jo cancel ka button hai usko long press kr k rakhana ek veep k awaz ane pre button chod dena fir cancel ka button bar bar press krna 2bara veep ki awaz ane pr chek krna k remote me kya code aa raha hai
@@honeychahal9364 ha maine error code check kiya tha ussme L5 error code ara tha aurr L5 error code maine manual mai dekha yo ussme likha hai outdoor unit over current ! , Vaise to PCB naya aagaya hai bass fitting karna baki hai ajj technicians ane vale hai abb dekhte kya hoga
Mera AC LLOYD ka hai Uske indoor ki display pr EC likhkr ata hai or fr compresure bnd ho jata hai Or zyadatar bina EC dikhaye bhi compreasure bnd ho jata hai Esa kyun
sir EC error ke 2-3 karan ho sakte hai common case hota hai k gas leek ho gas low ho no 2 pcb ki problem ho sakti hai and no 3 koi connector louse ho sakta hai abi in me se aap k ac ki problem konsi hai j check kr k he pata chle ga
@@honeychahal9364 mujhe kisi ne bola ki.daikin ka ac nahi lena, kyuki company koi bhi spare part sell nahi karti. Repair service centre main hi karwani hoti hai.
Mere paas Daikin ka inverter AC hai. 18 degree krne pr bhi compressor on nhi ho rha. Even power chill mode on krne par bhi compressor nhi chal raha. Urban Company se technician ko bulaane pr unhone bataaya ki PCB kahraab ho gaya hai outdoor unit ka aur replacement ka cost 10000 se 11000 k beech padega! Aap kya suggest krte hain yahan aur kya unse PCB replace karrana chaiye?
@@honeychahal9364 aap magakar hamare address par send kar sakte hai hai kya mai payment bhi kar dunga aap ke account me please ho paye to bataeye same model hai pcb ka sir
@@honeychahal9364 sir meri godreg ki ac h .outdoor fan nhi chal raha company wala aaya tha bola outdor pcb kharab h 19000 RS ka khrcha ayega pcb change hogi.
Very good video sir...please let me know where to get the PCB board for Daikin 1.5 Tn Inverter AC model FTKV50N
Available
Address please
Aligarh
Is yor product out of pcb warranty? or why you purchased the pcb for 6500rs ? Please tell
अरे भाई NON INVERTER AC लेना चाहिए वह बढिया रहता है। उसमें out door में कोई PCB नही होतीहै मेने तो mitsubishi का 1 .6 टन का Ac लगवाया है। बहुत मस्त चल रहा है चार साल से सिर्फ सर्विस करवानी होतीहै साल में एक या दोबार 400 -500 रुपये लेता है टेक्नीशियन मामला चका चक
Haa bhai sahi bolaa ❤ outdoor pcb mehnga bhi padta hai 9 say 10 hajar ₹ wasul lete service center waale
so many mosquitoes... it can be clearly seen in the video. Very nice video... thoroughly explained. Thanks for this video dear!
Thanks 🙏
Compressor na chln di problem c ji
Sir, i would like to ask about the problem of the daikin multi split indoor unit working fine and not blinking but the outdoor compressor and fan are not working, the PCB is also problem ?
i hope you can give me an explanation so that i can know about this knowledge, Thank you
Aap remote se error code check kro or batao kya code aa raha hai
Cancel button ko long press kro veep ki awaj ane tak fir cancel button ko bar bar press kro agar kise code pr long veep ki awaj aati hai wo code comment me type kro
@honeychahal9364 i did that and got U2 error. I have the same problem as that guy. I found the capacitor C85 has infinite resistance across it, could that be the issue?
@matttzzz2 u2 error me jyada tar pcb ka capacitor he change krna padta hai 20uf ka laga sakte ho daikin ki pcb me
bhai mne ek chij notice ki h ki daikin ke AC me minimum 2 rows ki to coil hoti hi hai....mere voltas ac me 1.5 rows h outdoor unit pe wo 3 star inverter h apka daikin 3 star h ya 5?
sir aap k ac me cost cutting ki gai gai 2 row hoti hai 1.5 ton ac me
@@honeychahal9364apka ac kitne ton ka h n kitne stars wala h? Aur konse year ka model h? Pls bata dijiye jaldi
@rahulthapa2921 2015 model ac hai 1.5 ton ka hai 2015 me star rating nahi this inverter ac me
Outdoor fan is not working but compressor is on , what will be problem
fan motor khrab ho sakti hai wire ki problem ho sakti hai & capacitors week ho sakta hai
Pcb remove kar ke non inverter bana sakate he
No nahii ban sakta inverter ac ka compressor dc current pr chalta hai or non inverter ka Ac current pr
What is the price of out door pcb for daikin 1.5 ton split AC
sir. mere ac me trip ki problem hai 3 4 second chal kar band ho jata hai out door. mai naya pcb lena chahta hoon. us kaha se magaen. aur kitna cost ayega. sir please bataye.
sir app error code check kro fir aap ko pata chl jaiga k kya problem hai agar outdoor cut kr raha hai ho sakta hai k pcb ki problem ho agar voltage proper na ho fir v cut kr jata hai ac
pcb aap ko daikin service center say lane hogi cost har model ki alag alag hai mere ko 6500 ki mili hai
What's the cost of this PCB ??? What is your model no.?
6500 model no ftkp50prv16
Universal pcb chaiye inverters ka
हनी भाई, आप का शौक है या आप प्रोफेशनली ये काम करते हैं?
nahii sir j mera kaam nahi hai main saunk se krta hu aur agar kise ki koi help ho jati hai mere ko achaaa lagta hai
Link mile ga kya buy karne ke liye
where did you put request from, online or any daikin service center phone number?
Mujhe bhi yhi pcb mangwani hai
sir mill jai gi
Daikin Pcb ki warranty kitni hoti hai??
5 year
Kitne ton ka ac hai?
1.5 ton
paaji 1.5 ton ka window ac lena hai, kon sa le? bs ek requirement hai har saal repair na krwana pada, bada mehnga kharcha hai wo
daikin 1.5 ton 5 star window achaaa ac hai 5 star model he lana
@@honeychahal9364 lg ka kaisa hai? Usme 4 star me bijli bahut kam le raha
sir bijli kam le raha hai sahiii hai agar koi problem aa jati hai repair cost jyada hai uski electronic part jyada hai us me
Nai pcb kaha se male gi
Service center se mill jaigi
i have daikin split ac. Even room temprature is 29-30 when I set to 26 the compressor is not starting and it start if I lower to 24. I have already replaced the capacitor (outdoor) and temperature sensor(indoor circuit with sensor). Any suggestions? Aur error code 00 ata hai.
sir ac me koi problem nahii hai 00 error code nahii hota hai
@@honeychahal9364 Sahi bat hai. Par room temprature 28 hota hai to b compressor chalu nahi hota hai. Aur 26 set karu to 1-2 min chalake trip ho jata hai.
sir abi jo mosam chl raha hai is me ac low temperature pr he compressor on krta hai abi rainy session chl raha hai 25-26 pr v compressor jyada nahii chlta jaldi trip kr jata hai aap k ac me koi problem nahii hai
agar aap ka ac 18-20 pr set krne pr v jaldi cut kr raha hai fir ac me problem hogi aap ka ac sahii hai
Sir ye pcb kaha se milegi? Humre city me nhi mil rhi. Please help krde isko lene me
Problem kya aa rahii hai ac me error code kya aa raha hai
@@honeychahal9364 sir spark hua tha outdoor unit me .... Technician ne bataya pcb me fault aaya h.... Repair waalo ne bola repair nahi ho payegi pcb..... Problem thi ki spark k baad se compressor 1-2 minute start hoke band hojaara tha.. aur fir 5 minute baad 1-2 minute k liye start horha hai...
Voltage fluctuations k wajah se aisa hua tha sir
@rishabanand5846 aap pcb ka capacitor change kro agar error code u2 aa raha hai 20 uf ka lagega
Bhai compressor trip hojata hai baar baar Daikin vale bolre hai ki PCB ka problem hai , apke hishabh se kiska problem ho sakta hai ??
sir voltage ki problem ho sakti hai agar voltage sahii hai fir pcb me problem ho sakti haiii aap error code check kr lo pata chl jaiga k kya problem haii
remote me jo cancel ka button hai usko long press kr k rakhana ek veep k awaz ane pre button chod dena fir cancel ka button bar bar press krna 2bara veep ki awaz ane pr chek krna k remote me kya code aa raha hai
@@honeychahal9364 ha maine error code check kiya tha ussme L5 error code ara tha aurr L5 error code maine manual mai dekha yo ussme likha hai outdoor unit over current ! , Vaise to PCB naya aagaya hai bass fitting karna baki hai ajj technicians ane vale hai abb dekhte kya hoga
yes sir L5 pcb ka he hai outdoor ki pcb ka maine v apne ac v pcb change ki hai L5 code aa raha tha
video v hai channel pr pcb me paste jroor lagwa lena agra na laga pcb 2bara khrab ho sakti hai video v check kr lena
Mera AC LLOYD ka hai
Uske indoor ki display pr EC likhkr ata hai or fr compresure bnd ho jata hai
Or zyadatar bina EC dikhaye bhi compreasure bnd ho jata hai
Esa kyun
sir EC error ke 2-3 karan ho sakte hai common case hota hai k gas leek ho gas low ho no 2 pcb ki problem ho sakti hai and no 3 koi connector louse ho sakta hai abi in me se aap k ac ki problem konsi hai j check kr k he pata chle ga
@@honeychahal9364 sir gas abhi prhi hai, or indoor me hole tha uski bhi velding hui hai..
sir ek bar check krwa lo ho sakta hai fir se leek ho gai ho agar gas proper fill na ho fir v ja problem aati hai
@@honeychahal9364 gas ki quantity kitni hoti hai isme
sir outdoor per likha hota hai k kitne gas aiy gi
sir. mai u. p. mau se hoon
Bhai ji mujhe bhi yhi pcb mangwani h
sir daikin service center se mill jaigi aap ko
Daikin company apna maal open market main sell karta hai. ???
No
@@honeychahal9364 fir spare part kaise de diya tumko.
@narutosingh5239 service center se mill gya tja mere ko aap v pata kro kise pass k service center me mill jaiga
@@honeychahal9364 mujhe kisi ne bola ki.daikin ka ac nahi lena, kyuki company koi bhi spare part sell nahi karti. Repair service centre main hi karwani hoti hai.
Sir baat puchni thi mitshibushi electric non inverter me pcb kitni hoti hai
non inverter ac me 1 pcb hoti hai sabi ac me
Nahi bhai non inverter ac ke Kai model me 2 PCB Bhi hote han Mitsubishi split me 2 PCB hote han main Kai repair kar chikan hun
Mere paas Daikin ka inverter AC hai. 18 degree krne pr bhi compressor on nhi ho rha. Even power chill mode on krne par bhi compressor nhi chal raha. Urban Company se technician ko bulaane pr unhone bataaya ki PCB kahraab ho gaya hai outdoor unit ka aur replacement ka cost 10000 se 11000 k beech padega!
Aap kya suggest krte hain yahan aur kya unse PCB replace karrana chaiye?
sir aap daikin se pcb change krwa lo 6000 se 7000 me change ho jaigi or daikin ki warranty v hogi
daikin customer care pr complaint kro aap
Thank you so much for the help!
@@honeychahal9364 Demanding Rs.9300 for Out Door PCB and Rs.1000 fitting charge............
agar service center me j price mill raha hai fir sahii hoga depend krta hai model to model kisi ka price km hai kisi ka jyada
Purchased from details
PCB purchase shop details details plz.
sir jis company ka ac hai un k service center se mil jati hai aap apni location pr service center search kr lo
@@honeychahal9364 sir yaha par ye modal available nahi hai kya aap kuchh help kar sakte hai? Agr kar sakte hai to
..............so please
sir app daikin k service center me call kro aap ko pcb mill jaigi
main aap ki kya help kar sakta hu ?
@@honeychahal9364 aap magakar hamare address par send kar sakte hai hai kya mai payment bhi kar dunga aap ke account me please ho paye to bataeye same model hai pcb ka sir
Daikin
Company wale difect pcb bhejrahe hy pura frod chala rahe hy company wale
Sir aap apne pcv ka photo send kro un ko bolo k j wala pcv lagega
Pcb ka price kya h
6500
@@honeychahal9364 kya har model ka alag alag price h ki same (godreg 5 star ⭐ac h
sir price me difference hota hai har model me
@@honeychahal9364 sir meri godreg ki ac h .outdoor fan nhi chal raha company wala aaya tha bola outdor pcb kharab h 19000 RS ka khrcha ayega pcb change hogi.
sir 19000 bahut jyada hai isse achaa hai k app new ac buy kr lo isko sale kr k