Hello my dear friend. Your project is great. I could not fully understand the serial-parallel topology. I would be very grateful if you could send me the schematics by e-mail. If you can't do that, my question is, do I have a chance to catch resonance by changing the frequency of the power circuit instead of this series circuit?
what happen with the current in the inverter when you connect a series resonant in series to aparallel resonant and both are at the same resonance frequency
but for example if the impedance of the serial circuit at resonance its only a resistive load and i don have any resistence conected in mi network, the current in the inverter will be very very high or not ?
remember that this topology combins the behaviour of serios resonant and parallel resonant together wich means when u put a huge load like a big piece of steel un work coil, the inveter current will be quite high and in reverse if u put anything the current will be minimum but in all situation current will be almost sinusidual and this topology has a linear behavior
The current passing through your inverter is the same as the current through your resonant series circuit? , On your 3kw machine how much current goes through them? And how much goes through your parallel tank circuit?
this girl its on fire!!!
Hello my dear friend. Your project is great. I could not fully understand the serial-parallel topology. I would be very grateful if you could send me the schematics by e-mail.
If you can't do that, my question is, do I have a chance to catch resonance by changing the frequency of the power circuit instead of this series circuit?
what happen with the current in the inverter when you connect a series resonant in series to aparallel resonant and both are at the same resonance frequency
Edgar Reyna Torres
inverter sees a pure resistive and sinusidual load
but for example
if the impedance of the serial circuit at resonance its only a resistive load and i don have any resistence conected in mi network, the current in the inverter will be very very high or not
?
Edgar Reyna Torres
im not sure what u mean
but if u mean inverter curent at non load situation
its still sinusidual but in mnimum value
remember that this topology combins the behaviour of serios resonant and parallel resonant together wich means when u put a huge load like a big piece of steel un work coil, the inveter current will be quite high and in reverse if u put anything the current will be minimum but in all situation current will be almost sinusidual and this topology has a linear behavior
The current passing through your inverter is the same as the current through your resonant series circuit? , On your 3kw machine how much current goes through them?
And how much goes through your parallel tank circuit?
bhai apka phn num