Siemens S7 1200 PLC to Schneider VFD Modbus communication.

Поделиться
HTML-код
  • Опубликовано: 4 дек 2024

Комментарии • 26

  • @yoonessalehi
    @yoonessalehi Год назад +1

    It was great and complet.

  • @davitos1000
    @davitos1000 Год назад +2

    excelente video !!
    Gracias por este conocimiento, sufrí mucho para parametrizar el modbus en TIA portal, pero ahora ya tengo un nuevo poder !

  • @jrffabiano2544
    @jrffabiano2544 6 месяцев назад

    TOP PROFESSOR! FUNCIONOU PERFEITAMENTE .

    • @AutomationBD
      @AutomationBD  6 месяцев назад +1

      Thanks for stay with us.

  • @leninpastrana2713
    @leninpastrana2713 5 месяцев назад

    Amazing!!!! thank you very much and blessings

  • @alolaloa
    @alolaloa 4 месяца назад

    Do you have the connection diagram between the source, the PLC, the VFD and the motor?

  • @amarnathnsw9392
    @amarnathnsw9392 Год назад +1

    Make a video sir on how to configure profibus communication with Tia portal to abb dc drive

    • @AutomationBD
      @AutomationBD  Год назад +1

      Wait for me I will make a tutorial about this

  • @gulamansari7630
    @gulamansari7630 6 месяцев назад

    Will this setup work for altivar 930 vfd with Modbus TCP and s7-1200 Ethernet switch?
    Will a normal Ethernet cable work between altivar modbus and s7-1200 Ethernet switch?

  • @hightechplatform1874
    @hightechplatform1874 8 месяцев назад +1

    thanks for the nice video, please one question regarding the holding regisers, you used the hexa address 8501 and you have chosen the related bits among of 16 bits, my question that i am really confuesd of how to convert any bits from bit 0 to bit 15 into decimal number, is there a methode that helps me to understand better, because it is not clear to me, for example you chose bit 12 and you converted into decimal , can you please explain it . thx

    • @AutomationBD
      @AutomationBD  8 месяцев назад

      You can used PC calculator. There selection programmer. There you easily change bit to decimal number.
      Thanks for stay with us.

  • @joeltshiela4605
    @joeltshiela4605 2 месяца назад

    ❤❤

  • @connordembrowski485
    @connordembrowski485 Год назад +2

    Is this modbus TCP or RTU?

  • @taha.anajjari597
    @taha.anajjari597 Год назад +1

    What is the type of modbus cable you use??

    • @AutomationBD
      @AutomationBD  Год назад +2

      2 wire cable cable.
      Plc side 9 pin connector in 3 and 8 number pin connection.
      Drive side rj 45 connector in 4 and 5 number pin connection.

    • @alvi13akif
      @alvi13akif 4 месяца назад

      @@AutomationBD Correction
      2 wire cable cable.
      Plc side 9 pin connector in 3 and 8 number pin connection.
      Drive side rj 45 connector in 4 and 5 number pin connection.

  • @eshwarwadekar596
    @eshwarwadekar596 Год назад

    😊😊😊😊😊😊

  • @erkumar6578
    @erkumar6578 4 дня назад

    If you put your voice in the version.. will something wrong with you???

  • @Tinhinane721
    @Tinhinane721 3 месяца назад

    ممكن شرح بدون موسيقى

  • @Tinhinane721
    @Tinhinane721 19 дней назад

    اين هو شرح ؟

  • @Tinhinane721
    @Tinhinane721 3 месяца назад

    ممكن شرح من صفر