school portable moving. Disconnecting fire alarm, electrical, security and all services.

Поделиться
HTML-код
  • Опубликовано: 1 ноя 2024

Комментарии • 59

  • @nics-systems-electric
    @nics-systems-electric  Год назад

    Part two, lifted and moved to new location video. ruclips.net/video/NEqfLdOITAE/видео.html

  • @jeffmoss26
    @jeffmoss26 Год назад

    Dude has a key ring on each side. True professional right there!

  • @72chargerse72
    @72chargerse72 Год назад +1

    28 years as a fire tech. did sec network intercom phone etc... lots of schools and portables... fun times. G,lad Im done.

  • @WNFlyer
    @WNFlyer Год назад +3

    Hey Nic. Thank you for uploading these videos. I don't have any interest in this field but I've been watching your videos the past few weeks and they are pretty entertaining and I also get to learn something new! 🙂

  • @aerhardt
    @aerhardt Год назад +3

    I have always wanted to see how this is done!

    • @nics-systems-electric
      @nics-systems-electric  Год назад +1

      Just wait till next week's Saturday upload wear these things get moved!

  • @Firealarmcollectorperson
    @Firealarmcollectorperson Год назад +4

    19:40 “it looks scary in there” cmon Nic, don’t scare the kids lol.
    Nice video though! I really like these longer maintenance type videos.

    • @nics-systems-electric
      @nics-systems-electric  Год назад +1

      Lol I told him when I went out it's not scary just hot as hell in there

  • @RVFireFighter
    @RVFireFighter Год назад

    you should pull the loop off the panel for the zone you are working on. You said "I should have brought a meter." Yes if you were wearing a tool pouch it would be easier. You need a tone generator to mark your loops. and use the 2 way radios more.

    • @nics-systems-electric
      @nics-systems-electric  Год назад +1

      I personally don't like wearing tools you can't just pull off the loop of what you're working on when it's an addressable system with just one loop

  • @A_Canadian_In_Poland
    @A_Canadian_In_Poland Год назад

    Are there local codes requiring a sprinkler system in your area? The National Building Code of Canada doesn't require a sprinkler system for a small building the size of 1 portable classroom (A2 occupancy less than 400 m^2).

    • @nics-systems-electric
      @nics-systems-electric  Год назад

      Yes each municipality has its own requirements and they want them sprinklered in my municipality so if you go 5 km the other way it's not required lol

  • @ForTheBirbs
    @ForTheBirbs Год назад

    Good work. Nice video. Cheers

  • @marksmith-ew7ir
    @marksmith-ew7ir Год назад

    Takes alot to undo the miss wired porter cabins, if it don't work try a bigger and see if problems go away, which it's not a good practice.
    You done your best to rip out old and altered wires that's been moved or modified over the year's that should result from false alarms, then you can relable the fire panel to correct settings so any caretaker or engineer knows what triggering or fault finding.

  • @stephengreene3134
    @stephengreene3134 Год назад +4

    Seems like every time y’all work at this school there’s always something messed up and the job ends up more complicated than it should be. Hahaha

  • @djahries
    @djahries Год назад

    Would you ever do a video regarding a schools PA system and the programming/wiring of them? They're all power over ethernet based correct?

    • @nics-systems-electric
      @nics-systems-electric  Год назад

      Probably not I don't know enough about PA systems. No most are not power over Internet often times they use data cable and data connections into a switch but that switch is a amplifier

    • @djahries
      @djahries Год назад

      I've always had a ton of interest in the inner workings of those systems. I know that my schools intrusion alarm is tied to the PA as well, should it trigger the same long chime tone is produced through the system. Do the fire alarm relay and intrusion system connect to a simple panel in the office or is there usually a large rack system that it is all connected too? You're answering all my long time questions!

    • @nics-systems-electric
      @nics-systems-electric  Год назад

      @@djahries it's only a couple new schools that have connection to the fire alarm and in those schools it's done by a relay module tied in to rackmount amplifiers that use data connection to the speakers

    • @djahries
      @djahries Год назад

      How would I upload/send you a video so I can get your insight? I think you'd be interested in hearing what I mean.

    • @nics-systems-electric
      @nics-systems-electric  Год назад

      @@djahries my instagram

  • @croc131
    @croc131 Год назад

    can different panels have different resistor’s or is there a standard ohm rating, and can the resistance needed be changed in the panel HMI or is its set into the motherboard RAM?

    • @nics-systems-electric
      @nics-systems-electric  Год назад

      Different panels from different brands and even panels from the same brand all use different resistor values sometimes different circuits on the same panel will use different values too

  • @ElliottVeares
    @ElliottVeares Год назад +1

    You really could do with a remote annunciator/control panel over where the portables are. Sees like a complex way to have all those modules rather than have a fully addressable system.

    • @nics-systems-electric
      @nics-systems-electric  Год назад +2

      They could've made the portables addressable though there wouldn't be much benefit for small individual buildings if they did go addressable they would still require the same amount of modules anyways as you have to isolate each one

  • @Teslamaniac
    @Teslamaniac Год назад

    Oh that would be so easy for me, it would be like having a dump

  • @matthewantonucci6751
    @matthewantonucci6751 Год назад

    Hey Nic, The Noise I'm Hearing From The Power Suplies Inside Sound's Like Some Of My Favorite Newer Late 1990's Style Direct-Air Hoover Legacy Elite Vacuums!

  • @uniteddrones7626
    @uniteddrones7626 Год назад

    4:31 middle panel for DSC, is that a zone expander for all the portables?

  • @matthewantonucci6751
    @matthewantonucci6751 Год назад

    Hey Nic, I Hope You're HoldingUp With The WildFires Just Fine!

  • @mikeross880
    @mikeross880 Год назад

    Excellent video Nic, very well doucumented from beginning to end BUT....Is that a black widow under that deck there? From the looks of things looks like most of the components (communications, security, fire alarm) were pretty well labeled cause with portables it's never about "IF" they'll be moved but when.

  • @GaryBeltz
    @GaryBeltz Год назад

    Just curious while you were working on the alarm system why didn't you disable the NACS?

    • @nics-systems-electric
      @nics-systems-electric  Год назад +1

      Because you can't set the system off from working on the nac's and you'd have a trouble if it's disabled and you'll have a trouble if you're working on it so it's the same thing either way

    • @GaryBeltz
      @GaryBeltz Год назад

      @@nics-systems-electric makes sense I was just thinking since you guys were so concerned over people freaking out should the bells have gone off that you would’ve done that

  • @KanoaDeCastro
    @KanoaDeCastro Год назад

    This was the same school with the mislabel shenanigans, right?
    If so, those are 2 less portables that the system can fuck up.

  • @brianfortuna6691
    @brianfortuna6691 Год назад

    👏🏻👏🏻👏🏻

  • @Granth_Man
    @Granth_Man Год назад

    Hey Nic I love your vids❤ And I want to tell you that I made a emergency light 💡 😊

  • @Corwin09-ji8sx
    @Corwin09-ji8sx Год назад

    "Good evening, @NIC's Systems And Electric, from Corwin09_USA. After a shortwhile, TWO of your schools, both an Elementary and a Middle School was leaked?! No way! Viewers, beware!"

    • @nics-systems-electric
      @nics-systems-electric  Год назад

      It is what it is can't hide everything though I'm not even sure where anything was shown

    • @Corwin09-ji8sx
      @Corwin09-ji8sx Год назад

      Well, with both an elementary school and a middle school in your district leaked on Google Maps, it is only your secondary school and your house is leaked on Google Maps!

    • @nics-systems-electric
      @nics-systems-electric  Год назад

      @@Corwin09-ji8sx oh well I never said the name of them so obviously it's visible somewhere

    • @Corwin09-ji8sx
      @Corwin09-ji8sx Год назад

      ​@@nics-systems-electricOnly a matter of time, beware!

    • @captainchris2016
      @captainchris2016 Год назад

      This is a problem with the fa community. Lots of people are not giving others privacy just to get peoples addresses with no reason to have it. Unfortunately this is common with most online communities.

  • @Ollieiow08
    @Ollieiow08 Год назад

    19:02 there's an arm on the door...
    Edit: it might be a mirror actually

  • @CapStar362
    @CapStar362 Год назад

    Is this that same school that gave you all that hell about a month ago?

    • @nics-systems-electric
      @nics-systems-electric  Год назад

      Yes

    • @CapStar362
      @CapStar362 Год назад

      @@nics-systems-electric that school is pure hell bro. id be like, we tearing this ENTIRE SYSTEM out and re-doing it 100%
      LOL!!!

  • @skorhed287
    @skorhed287 Год назад +1

    First comment

  • @CarswDalton
    @CarswDalton Год назад

    2nd comment

  • @ObamnaSoda513
    @ObamnaSoda513 Год назад

    whats todays video gonna be on