Using a Digital Manometer to Set Furnace Natural Gas Pressure

Поделиться
HTML-код
  • Опубликовано: 26 июл 2024
  • НаукаНаука

Комментарии • 42

  • @mcfrenchfry2196
    @mcfrenchfry2196 3 года назад +1

    Great Job Dave, covered it all. I’m ready Now!!

  • @Habibthehvacguy
    @Habibthehvacguy 5 месяцев назад +2

    great video thanks

  • @JerryLynch2
    @JerryLynch2 Год назад +2

    Nice job!

  • @sujeevansegaram2001
    @sujeevansegaram2001 Год назад +1

    Great video. If I might say so, your hand is blocking the camera from capturing exactly what you're doing. ie. when you're unscrewing the port.

  • @AvonByTheSea82
    @AvonByTheSea82 3 года назад +1

    Well made video, thanks.

  • @steelod1528
    @steelod1528 2 года назад +1

    Whats the size of the stiffer hose use to slide over newer gas valve I can't find a kit for it anywhere.

  • @stephenbickley4006
    @stephenbickley4006 3 года назад +2

    Do you have a pt# for the new style gas valve adaptor?

  • @seek3n
    @seek3n Год назад

    I took a class on the furnace. It mentioned I have to check the gas provider pressure, run the furnace and time clock the gas meter. I couldn't find any video talking about it. It would be great if you could make one. Thanks for the content!

    • @TECTubefilms
      @TECTubefilms  Год назад

      Make a video on clocking the gas meter? Not sure how that would help for setting up the gas pressure. The best way to set the gas pressure is to measure the gas pressure.

    • @TECTubefilms
      @TECTubefilms  Год назад

      Who/where was the furnace class you took? It wasn't in one of our labs was it?

    • @seek3n
      @seek3n Год назад

      @@TECTubefilms oh no, it was a training from carrier enterprise. Told us we have to time the gas meter see how many revolution and then calculate and match btu on furnace.

    • @TECTubefilms
      @TECTubefilms  Год назад +1

      @@seek3n That will just tell you how much gas you are consuming. Not sure how you would set the gas pressure based on that. Plus wouldn't it be easier to hook up your manometer at the furnace and adjust the gas pressure while you are looking at the meter in real time?

  • @kevinebersold9996
    @kevinebersold9996 3 года назад +6

    Camera too far away!
    More closeups...less you!

  • @gnaneshsiva9193
    @gnaneshsiva9193 3 года назад +2

    Thanks

  • @mark.r8900
    @mark.r8900 3 года назад +1

    Hi, my low stage reads 3.8"wc. I've tried turning the adjustment screw to bring it down to around 1.7"wc. But turning the adjustment screw has no effects. Is it a bad gas gave then? Thanks

    • @concernedpersons1995
      @concernedpersons1995 2 года назад +1

      Sounds like a bad gas valve. I had one yesterday that isn’t letting gas through it.

  • @edwing8862
    @edwing8862 4 года назад

    Can you calibrate those manometers? I have the same one I just bought. And the numbers keep fluctuating up and down.

    • @TECTubefilms
      @TECTubefilms  4 года назад

      Take a look at the Field Piece instructions under the section called Field Calibration. www.fieldpiece.com/media/manuals/Opman-SDMN5-v15.pdf

    • @TECTubefilms
      @TECTubefilms  4 года назад +1

      Although, hunting/fluctuation is generally not a calibration issue.

    • @RJMaker
      @RJMaker 4 года назад +2

      They are sensitive to temperature changes. So if you're bringing in from a cold or hot truck you will need to let the meter's temp stabilize to it's new environment temp. before using.

  • @timaldrich4750
    @timaldrich4750 Год назад

    How would you do the high fire adjustment if you have only one "W" on the thermostat terminal strip of a 2 stage furnace?

    • @TECTubefilms
      @TECTubefilms  Год назад

      Are you saying that you have a two-stage furnace where the furnace does not have a W1 and a W2 input? Or are you saying that you have not wired the thermostat to both W1 and W2 on the furnace?

    • @timaldrich4750
      @timaldrich4750 Год назад

      @@TECTubefilms I’m saying that that the thermostat terminal strip on the circuit board has Red for power, Yellow for AC, Green for blower, White for heat and Blue for common.

    • @timaldrich4750
      @timaldrich4750 Год назад

      Jumper goes to red(power) and white(heat) for the low fire and want to know jumper connection for high fire - thanks.

    • @TECTubefilms
      @TECTubefilms  Год назад

      @@timaldrich4750 If there is no W2 input on the furnace, it is not likely a 2-stage furnace. We represent 6 brands of furnace and all 2-stage models have both a W1 and W2. Are you sure it is a 2-stage? Does the gas valve have wiring labels for both Lo and Hi?

    • @timaldrich4750
      @timaldrich4750 Год назад

      @@TECTubefilms Thanks Tec Tube for your help.
      Yes it is a Goodman GMH95 gas furnace. Also on the circuit board next to the thermostat terminal strip is a dip switch which can be moved to 1stage or 2 stage. In addition, the gas valve has a low fire adjustment port and a high fire adjustment port.

  • @CarlosHernandez-ih5eq
    @CarlosHernandez-ih5eq 10 месяцев назад +1

    I don’t understand why you dont show pressure coming into gas valve that should not be skipped. Think thats part of the steps when checking gas pressures

  • @coreym5072
    @coreym5072 Год назад +1

    How often do you have to calibrate your furnace?

    • @TECTubefilms
      @TECTubefilms  Год назад

      The gas pressure only needs to be set once... preferably when the system is first installed.

  • @bobtwo
    @bobtwo 2 года назад +1

    You are assuming all gas is the same, mine is propane very different settings

    • @TECTubefilms
      @TECTubefilms  2 года назад +2

      True. Our market has less than 5% propane furnaces so we normally think about natural gas here. We will change the name of the video to clarify that this is for natural gas.

    • @bobtwo
      @bobtwo 2 года назад

      On RUclips you have no local market, look smart add propane, thanks much

    • @TECTubefilms
      @TECTubefilms  2 года назад

      @@bobtwo True. But honestly, we only care about the contractors in our market. Anyone else who stubbles upon our page is cool, but not someone we are going to sell products to our take support phone calls from. LOL
      But in either case we did change the name of the video yesterday to state "natural gas" to avoid any confusion for those in other markets that use a lot of propane.

    • @reygama321
      @reygama321 7 месяцев назад

      Ultra low nox is not going to work with propane amigo

  • @ParabellumX
    @ParabellumX Год назад

    You don't recommend first turning off the gas when connecting the manometer to the furnace?... 🤷🏻‍♂️

    • @TECTubefilms
      @TECTubefilms  Год назад

      Why?

    • @ParabellumX
      @ParabellumX Год назад

      @@TECTubefilms I'm not sure, actually.
      I'm going to assume it's for safety reasons.
      I just started going to college for HVACR last year; so this is all new to me. But every other RUclips video that I've watched (where an individual is teaching how to connect a manometer to a gas valve in order to test the gas pressure), they always turn the gas off first. After connecting it properly, then they turn it back on.
      Maybe it's so gas won't enter the space that the technician is in, possibly igniting an external fire source (such as a gas stove downstairs in the conditioned space or something)? 🤷🏻‍♂️😆

    • @eastsidepyro2685
      @eastsidepyro2685 11 месяцев назад

      pansy