Sir ,mera ETS room ka ek pump trip kar gya tha iske liye maine ,main incomer se manually reset kar diya lekin koi bhi pump auto mode me karne pe koi bhi pump run nhi kar raha hai ,or HMI digital panel me ,: (Failed to open connection to PLC ModbusEquipment01) Aisa error aa raha hai
For acceleration time setting parameters no- 2202 and deacceleration parameter - 2203 and acceleration time meaning vfd ko start command phunchte hi motor 0 speed se reference speed tak phunchne ka time and deacceleration meaning vfd ko jab stop command di tab reference speed se 0 speed tak phunchne ka time.
Practical video good Sir. Thanks so much
Thank you so much
I'm watching from Bangladesh.
Your explanation is very good,
God bless you and your family
Thank you so much your explanation 2 wiri connection and parameters settings abb acs550🙏🏽🙏🏽
Thank you so much sir ji
Sir pot ko Nikal ke keypad se Hz set Karna ho to konn sa parameters change Karna padega
Good
Sir , plz continue series of ACS550
ALSO make vedio on DCS to ACS550 communication
Good information sir ji
AC tech small vfd bravun colour ka video banaye plz sir ji
Abb-acs 550 inverter how to run from Keypad and how to run from Potentiometer which program to set please tell me
sir abb acs 355 ka potencial meter se bhi connection same hoge kya
Nice
Motor ne kitna current liya kese chk karenge
Sir 4 to 20 ma pid ke liye complete parameter seting batain
Bhai mera vfd abb 355 hi 4:55 minat me video me dikhaya gya hi enter press krne par 9902 ho jata hi pr Mery me nahi ho pa rha hi
Sir me ek fix speed pe run karna chata hnu...then digital input se speed up down karna he but speed last reference speed se run horahahe...
Very much
ABB VFD Me Frame R1 Kya hota hai
Please bataye mujhe kya setting krne chahiye
Acs 355 abb drive frequency nhi rookti nhi hai selector switch on karne pr 54 hz motor goomne lagti hai
Thank you so much
Sir ABB ACS 550 ka 27 fault kasy niklta ha
Best
Thanks sir
ABB VFD mot overloadtem AA RAHA HAI KYA problem hai
Sir one video Autotuning plz
Motor ka (kw/rpm)details drive set points entry korlaaa dakhieaaa,one time plised
Sir ,mera ETS room ka ek pump trip kar gya tha iske liye maine ,main incomer se manually reset kar diya lekin koi bhi pump auto mode me karne pe koi bhi pump run nhi kar raha hai ,or HMI digital panel me ,: (Failed to open connection to PLC
ModbusEquipment01) Aisa error aa raha hai
Refrance signal kya hota h sir
Sir plc se start or stop karna ho to kha se conection karenge
Or HMI ke Display me GPM , temperature, pressure kuchh bhi nhi dikha Raha hai
Sar RPM metre ke bare mein nahin bataya aapane
ACS stands for????
Sir Push. Buttan. Se. Speed. Increase/deincrease. Veadio
Auto pe me chalne pe AA raha hai
Deacceleration and acceleration time kaise aur kitna set krta hai sir
For acceleration time setting parameters no- 2202 and deacceleration parameter - 2203 and acceleration time meaning vfd ko start command phunchte hi motor 0 speed se reference speed tak phunchne ka time and deacceleration meaning vfd ko jab stop command di tab reference speed se 0 speed tak phunchne ka time.
@@industryautomation6661 minimum acceleration and deacceleration time Kitna hona chahiye drive me
Motor ki capacity par depend krta hai agar choti drive hai to kam rakh sakte hai agar badi motor hai to jyada rkhna padta hai
@@industryautomation6661 good answer
Please answer me 🙏🙏
In motor potentio meter se
Asc 510 fault A2022
Thanks sir