Mike Wye Glasscrete Floor installation

Поделиться
HTML-код
  • Опубликовано: 14 янв 2025

Комментарии • 3

  • @keithdietrich
    @keithdietrich 4 года назад

    Yes !!! I love the expanded glass insulation... Any links about its embodied energy? Surely it's lower than typical concrete but references would be helpful too! Keep it up!

  • @patrickguyot1290
    @patrickguyot1290 4 года назад +1

    What thickness should each layer be please?

    • @MikeWyeLtd
      @MikeWyeLtd  2 года назад +1

      Hi Patrick - our apologies for the delayed response - your comment seemed to slip through the net! The lime screed will be 75mm, or 100mm if underfloor heating is included. The Geocell layer can be at a compacted depth no less that 120mm, though in most domestic retrofit projects tends to be at a compacted depth somewhere in the range between 150mm and 250mm.