What is a Digital Valve Controller?

Поделиться
HTML-код
  • Опубликовано: 29 ноя 2024

Комментарии • 27

  • @shashankgamanagatti965
    @shashankgamanagatti965 11 месяцев назад

    It's a great enhancement of IoT connectivity to valve sector 👏.

  • @josemanuelalogoadjomo7863
    @josemanuelalogoadjomo7863 7 месяцев назад +1

    wonderful video, just wondering whether there is a complete course on positioners offered by EMERSON and if there's
    who can I apply to??

  • @maurosotelo5509
    @maurosotelo5509 4 месяца назад

    Hola señor como esta? La verdad que es una excelnte explicacion!! Disculpe la molestia hay algun curso para hacer de valvulas posicionadores me podria dar infornacion xfavor entre a la pagina donde dise curso pero no me deja entrar

  • @kokinkokecruz4476
    @kokinkokecruz4476 5 лет назад +2

    You are so good explaining

  • @Practical.instrumentation
    @Practical.instrumentation 10 месяцев назад

    I'm facing issue with this type of positioner
    After calibration out put from positioner is not stable
    Valve begin hunting
    No solution is available

  • @joseluisjarana
    @joseluisjarana 3 года назад

    Tengo un problema a la hora de autocalibrar que en los porcentajes no son estables,oscila el posicionador.La alimentación correcta y todo correcto,como lo corrijo.

  • @mohammadsalah5482
    @mohammadsalah5482 2 года назад

    Please make video of relay I/P

  • @shaguftasayyed8019
    @shaguftasayyed8019 4 года назад

    Asl
    How one pair wire work analog output and analog output
    Question is if I am in junction box measure mA of valve if dcs send 8 mA and feedback is 12 mA what my Multimeter will show in JB
    I am confused how one pair wire work both AO and AI

    • @MilitantPrepping
      @MilitantPrepping 4 года назад

      I believe your Multimeter will show the 8mA signal from DCS, you will need something like a 475 to see both input and feedback

    • @MilitantPrepping
      @MilitantPrepping 4 года назад

      Hart is able to transmit input and feedback signal at the same time using slightly differing sine waves, it's also able to send ditigal hart signal along with analog signal at the same time over a single pair. Bell 202 + Analog signal

  • @85giby
    @85giby 5 лет назад

    One of our dvc6200 f in LOcal override mode..how can I change to Cascade mode?

    • @FisherControlValve
      @FisherControlValve  5 лет назад

      Hello, Please reach out to your Emerson sales contact on this topic. If you need help finding them please use: www.emerson.com/en-us/contact-us

  • @syedaslam2856
    @syedaslam2856 6 лет назад

    hi would some one clear my doubt as this DVC is a two wire controller how does the feed back of valve position to DCS and input from DCS works

    • @ramavelbala1
      @ramavelbala1 6 лет назад +1

      Feedback of the valve position to DCS is through communication protocol used. Either HART or Fieldbus communication. One is 2 way superimposed 4-20mA signal and latter is 2 way digital signal .

  • @145236ish
    @145236ish 4 года назад

    Hello,
    Can you please explain, if a Double Type relay will work with a single acting actuator. Are there any settings?

    • @FisherControlValve
      @FisherControlValve  4 года назад +2

      Relay A may be used with both Double Acting and Single Acting DVC6200 digital valve controllers. When using relay A as single acting there is an adjustment wheel in the relay that must be set by using a screwdriver. Rotate the wheel adjustment in the upward direction or negative adjustment indicated by the sticker on the front of the relay until the adjustment stops. This will set the Relay up to only operate using output A from the device. More information can be found in the DVC6200 instruction manual www.emerson.com/documents/automation/instruction-manual-fieldvue-dvc6200-hw2-digital-valve-controller-en-123052.pdf

  • @kokinkokecruz4476
    @kokinkokecruz4476 5 лет назад

    Excellent

  • @randomfellow6245
    @randomfellow6245 2 года назад

    does a DVC adjust pressure output to cover for actuator springs that are too stiff? for instance a 2" 10-30 that is only getting 1.5" 10-30, will the DVC ensure it puts 40lbs to the actuator to get that extra 1/2" of travel?

    • @FisherControlValve
      @FisherControlValve  2 года назад

      The DVC will continue to adjust output pressure until one of the following takes place:
      - Travel measured by feedback matches the desired set point
      - Maximum supply pressure is reached or
      - Zero output pressure is reached
      So it will compensate, but that will be limited by supply. However, if you find yourself tempted to continue to up the supply pressure we'd suggest reaching out to your local Emerson sales office to troubleshoot the root cause.

  • @brunomoralesflorentino9681
    @brunomoralesflorentino9681 2 года назад +1

    Este posicionador si se daña la bobina tienes que cambiar todo el posicionador contrario al 0osionador análogo

  • @israrullah4779
    @israrullah4779 4 года назад

    Sir how to join your class room, please assist, i am very much fond to seek sir plz any whatsapp or other link that i may avail

    • @FisherControlValve
      @FisherControlValve  4 года назад

      Hello Israr, Please visit www.emerson.com/en-us/automation/services-consulting/educational-services to help find training in your area.

  • @belaybekele2625
    @belaybekele2625 2 года назад

    wow amanjing

  • @shunty8254
    @shunty8254 6 лет назад

    Dear sir pls all video translate in Hindi..

  • @akramzmin4721
    @akramzmin4721 6 лет назад

    Pls translate in hindi

    • @hfcarwash
      @hfcarwash 2 года назад

      Hdufisncipsjhdksjdjhjsjd