Aalamin ang mga ppr fitting para motor pump at pressure tank sa laundry
HTML-код
- Опубликовано: 10 ноя 2024
- pressure tank air pressure,pressure tank for well system,pressure tank installation,pressure tank installation diagram,pressure tank philippines,pressure tank replacement,pressure tank troubleshooting,water pump replacement,well pump check valve,well pump not building pressure,well pump pressure switch troubleshooting,well pump troubleshooting,pressure tank,well pressure tank
They forgot to do the plumbing in the early stage of building, when they built the building. very odd .I never seen that before with all the plumbing on the wall not in the wall same with the drainage, The drain pipes should have gone in well before the foundations were laid.
Boss salamat at marami ako natotonan sa blog mo Sana sa sunod blog mo man kng ano combination Ng motor pump at laki ng pressure tank Ng ggamitin God bless syo
Ayos ka kailian maraming baguhan ang iyong naturoan at talagang inisa isa mong pinangalanan ang mga kakailananen ok ka god bless u
Eto ang pinaka-tama na setup na nakita ko. Salamat Sir!
pwede poba ganyang setup sa jetmatik pump.thank you po godbless🙏🏻
Yes Pwede po...
Good day po ano po pla klngan valve pra sa water booster vortex pump,, check valve or foot valve
Magandang araw din po Sa inyo.. Just follow my fb page .search nyo lang Ang" Tubero Sa cambanggo" to your fb. Pagkatapos sent me a picture or video nyan motor pump.nyo.maraming Salamat.
sir taga san ka sa pinas? pulido ka gumawa kaya gsto k malaman saan ka sa atin? thank u
Malakas po b papasok sa loob ng bahay ang tubig nya kht deepwell sya gamitan ng pressure tank?
bos pag ppr ginamit mo kailangan pa ba patuyuin yan bago gamitin pag nadikit muna. or a few second lng pwd na xa padaluyan ng tubig.
Yes, palamigin muna at para tumigas ang kapit 10 to 15 mins. Puydi na gamitin.
Master ung pinag kuhanan mu b Ng tubig ay galing s nawasa...Ng direct ho b kau
Hindi po Puydi, Mag direct tapping tayo Sa nawasa, Kapag nahuli ka, may multa, ipinagbabawal kasi.
Boss ask ko lang bakit po kaya matagal magpuno ng tubig yung tank..mahina po ba yung presure ng tubig??tapos may kasama siyang buhangin deep well po kasi to boss..my video ka po ba about po dun??
Tatlong dahilan ng mayrun dyan. Maliit lang ang HP na motor pump nyo. Pangalawa masyadong malalim ang pag kukunan or hihigupin ng tubig sa motor pump. Pangatlo kapag shallow type motor nyo. Hanggang 21 feet or 11 meters. Lang ang max deep ang makakaya.. Maraming salamat po...
sir russel torino m tanong q lng po,yung pressure switch, sadya po b doon nklagay s bandang itaas ng pressure tank?ano po ang reson bakit doon nk lagay s bandang itaas ng pressure tank?ano po ba ang advantage ng s taas o s baba,kz po yung iba nkkita q s my papasok ng pressure tank nk lagay e....
mas safe po.... pag nasa pressuretank ang pressure switch at gauge.para ma, detect kaagad ang pressure na nasa loob ng tangke, natin. upang maiwasan ang pagsabog.ang purpose ng pressure switch ay syang mag automatic on and off sa motor pump .
paano po mg set up nang pinapagawa skin ng boss ko.pwede po ba na nsa ground floor ang tangke.tapos nsa 4 floor ang motor at presure tank.ok lang po bang ganun ang set up.salamat po.
Ano po ba ang ang source ng tubig nyo deep well or nawasa. Kung sa nawasa, puydi lang magbypass kayo ng linya,ng tubig Galing nawasa, na hindi na dumaan sa pressure tank. Ibig Sabihin direct deposit to nawasa connection 1st floor fixtures and second floor fixtures. At sa roofdek or rooftop na ilagay ang storage tank nyo. tru gravity nalang ang 3rd at saka 4th floor fixtures.
Sir need p ba ng presuretank kung maglalagay ako ng Elevated Tank.. 3rd floor house po.. Salamat
Yes hindi sapat ang drop or gravity ng tubig sa elevated tank nyo. Lalo na kung Mayrunng kayong mga water heater.
Ilang HP ang Need para sa 3rd floor.. at saan po ilalagay ung Presurize tank? Salamat
1 HP shallow well pump. Sa taas nalang po. Kung mayrun pang space and at lagyan nyo nalang sya ng bahay bahay nya para Hindi maulanan
@@russelTorino sa 3rd floor po ilalagay ung presurize Tank? Rooftop?
Kung saan yong storage tank nyo dun din itabi ang pressure tank nyo.
Sir goodeve po... maganda po ba ang 2 Hp na aqua anh brandname..
Magandang araw po.... Matibay din po yan..
@@russelTorino salamat po sir.. ano po pala mas matipid interms sa kuryente sir... ung 42 gallons po ba or 82 for water pressurize tank?? Galvanize or stainless po?? Thanks po..
42 gals. Stainless pressuretank ideal for family dwelling. Thanks so much.. Stay safe...
Sir pwde poba ang 1.5hp sa 21galon?
Puydi lang po...
Sir tanung ko lang po, pwede po ba ipagsabay sa isang pressure tank with motor 1hp ang 1. "drinker" ng mga baboy? 2. at "power spray" na rin para sa kanilang dumi?
Puydi lang kung iilan lang ang baboy piro kung marami. Kailanganin mong ibukud ang para sa drinker nila.
Sir anong pipe ang gagamitin sa js10 goulds pump balon ang paglukunan need pa ba ng casing na tubo 2 at 11/4 Pano magkabit bg foot valve at packer ejector sana mapansin moh sir
Kailangan po talaga ang casing Kapag mayrun po ejector.
Usually 2 at 1 1/4" ang piping ang foot valve ay NASA Dulo ng pipe naka kabit. Suggest ko Lang po Sa ganyan set up or Gawain ay tumawag kayo ng expert na mga Tubero gagawa nyan .para mapadali at function able agad. Maraming Salamat.
boss yung water supply mo po b sa nasawa kumukuha ng tubig. at yung ball valve pwedi b dugtungan ng faucet. Slmat po sa sagot junior plumber pa lang po ako
Ang distribution pipe na Galing Sa nawasa, ay direct sa ball valve, huwag nyo po kabitan ng gripo.
yung ball valve na nakatayo sa motor Sir. lagyan ko sana ng faucet
For priming for purposes lang po yan, dyAn lang kayo puydi magkonek ng gripo Sa outlet pipe or discharge pipe ng motor pump.
kahit direct yun d na dadaan sa tank pwedi lagyan ng faucet.
Alam nyo Kapag, lagyan or pagkabitan ng gripo yan. Maging hindi accurate ang function nyan, at iinit ang inyong motorpump, na sanhi, ng pagkasunog sa winding, after ng pressure tank lang po kayo maari mag kabit ng mga faucet.
Sir any idea po kung bakit ang motor pump ay aandar siya if magbubukas ng faucet at continuous siya at titigil lng kung iooff ang faucet. Tapos pag umandar ang motor pump ay tataas naman ang pressure pero babagsak din agad tapos ang tubig na lumalabas sa faucet ay walang pressure. Thank you in advance po.
Kailangan nyo Lang po, mag drain ng tubig sa inyong pressure tank, Kapag, naubos ay isarado uli ang drain gate valve, at bago paandarin uli ang motorpump, sidlan nyo po muna ng tubig ang motorpump ( magpriming) pagkatapos umpisahan ng pAandarin ang motorpump. Kung bumalik na Sa normal ang cut off and cut on. Ay na,kabag or marami Lang tubig ang pressure tank.
Sir ano po mas matipid sa kuryente ung pressure tank o ung wala ung lalagay ko lng sa rooftop thnks you sir
Depende din po sa bahay nyo kung bongalo type Lang ...at ang mga fixture nyo ay waLang Heater...makatipid ka sa kuryente.piro mayrun oras na tipirin ka din po sa supply ng tubig...minsan hihina,minsan lalakas...
Boss tanong ko lang by pass bayong nasa ilalim na linya ng pressure tank ?
Yan po ay... Drain gate valve .buksan mo lang kapag mag linis ka ng inyong pressuretank. God bless you...
@@russelTorino ahhh ganun bha ok salamat idol. Diba pwede rin nmn lagyan ng end cup male jan sa ilalim tapos buksan lang kung magdrain ?
@@jasperbantigue2757 mahirapan kana mag bukas kung ung male plug. Kay sa lagyan mo ng gate valve madali nalang mag drain. Maraming salamat po....
@@russelTorino ahh ok2 sige idol maraming salamat idol dami ko matutunan dito...
Boos bakit hind magka level ang height ng dalawang entry at exit point ng tubig sa water tank......
+welmar casipe talagang ganyan amigo... para magkaroon ng compressed action sa loob ng pressuretank.
@@russelTorino ganoon bayun boss..hind kaya may specific na butas talaga pra lang sa boster pump dun???? Na kahit na maubosan ng water reserve ang tanke..ay meron paring natirang tubig sa baba pra mag feed sa boster pump??
@@russelTorino kasi boss..kong sakaling nawalan ng power supply ang pump mo sabihin na nating nag block out..lahat na reserve water sa tank mo ay malamang mauubus..kong sakali lang boss gawin mong exit suplly ng tubig ang nasa mataas na part na coupling maubos mang ang water reserve my natititang tubig parin sa baba pra mag auto feed ng tubig sa boster pump..rights?
Sir Myron ako malaki drum ng tubig, elevation pressure lang po, gusto ko sana lagyan ng electric pump, doon mismo kukuha sa malaking drum, para lumakas ang pressure sa loob ng house, paano po ba ang mga connection nya, galing doon sa malaking drum. At gusto ko rin sana lagyan sya ng bypass na Linya para kung sakali man na mag brown out myron pa ring tubig galing sa malaking drum
ruclips.net/video/HohuAypfRCk/видео.html paki click nalang po ang link na yan. Same lang din po sa gusto nyo salamat po god bless you.
Sa video na binigay nyo.po sir, hindi ko nakita yung bypass, kung paano gawin
sir anu po purpose ng float valve sa tanke??
Ang purpose po.. ng float ball valve sir ay mag refill ng tubig sa tangke kung itoy mababawasan.tulad nlang ng fill valve sa inyong mga toilet tank.na kapag i flush mo o mabawasan ay kusang mag on and of
bale double switch na ung set up na yan?
Hina ng background music MO idol lakas MO pa Kaya. 😂😂
Boss ganu b kalalim ang kaya ipump ng shallow watet pump
25 feet...katumbas ng dalawa't kalahati na 6 mtrs. na black iron pipe...
@@russelTorino boss may tanong po uli aq..kapag po nsa 20 psi na ung gauge ng pressure tank prang di na po nya kya itulak ung tubig papasok ng tangke ngiinit po ung pump..nglalaban po kaya or ngtutulakan ng pressure ung tanke at water pump?oe pg ganun kylangan ng mas mtaaad na horse power na motor salamat po
@@marviscurioso8490 check nyo muna ang rubber gasket ng poso. Kung ok.ba at walang singaw. At kung mayrun ba nakalagay swing valve before motor pump.
Wala sya swing valve boss ..nkaconnect ung pump sa poso tas union tas motor ... tapos motor then tee elbow tpos pipe..gate valve tapos pipe then naka connect na po sa tanke
Tanggalin nyo po ang gate valve sir. Palitan mo ng swing valve. At prime ng dalawa o tatlong besis. Hanggang gagalaw na ang pressure gauge pataas. Ibig sabihin nagkarga ng tubig at hangin. Maraming salamat po.....
Comment,ano Po Ang dahilan Kong bakit walang masipsip na tubig,e may tubig Naman sa deepwell,at bago din Ang electric pump
Mga dahilan : 21 feet ang maximum deep.. Na puyde PA makahigop ang 1hp shallow well pump. Kapag humigit na... Kailangan na ang deep well pump with ejector .second, sure po kayo na may foot valve yan Sa dulo ng tubo? Pangatlo.,Kailangan Mag lagay ng check valve Sa discharge pipe ng motor pump. At intake pipe. Maraming Salamat po...
@@russelTorino ok Po,just wondering lang po dito sa Tubero Kong nakuha if marunong ba talaga maginstall! Inip nako sa trabaho Niya,Kaya nag research ako Kong ano mga possible problem Kong bakit Hindi pa mapadaluyan NG tubig Yong kabahayan e almost 30k na nagastos including Drilling 2 1/2 tubo na Ang lalim ..may jetmatic na rin
sir mahina tubig sa amin my oras, meron sa aking binigay na best tank water tank at 1hp water pump gusto ko sana sir gawin presure water papuntang loob ng bahay.. ano nalang po ba kailangan ko bilihin ko. salamat sir
Sir...search mo lang po ang isa ko pa video na ang tittle ay :"PAANO MAG REDUCE NG PIPE LINE SA MOTOR PUMP AT PRESSURE TANK"
Paano po e set up ung bahay namin my 3rd floor. .bali may ground tank, pressure pump at tank at tank sa 3rd floor
ruclips.net/video/HohuAypfRCk/видео.html click mo nalng yan...ganyan po ang set up na gawin nyo...maraming salamat...po....
Boss bakit hindi po nag automatic off ung preasure switch ko? Umiinit na ung motor.
Una, tanggalin nyo muna ang plug Sa kuryente, or ibaba ang breaker Sa inyong motorpump, pagkatapos idrain nyo muna ang tubig Sa pressure tank, pag madrain na Lahat, isara muli ang drain gate valve, bago, paandarin ang motorpump, sidlan muna ng tubig ang motorpump, ito po ang tinatawag natin na "priming "at Kapag mapuno na tubig ang motorpump, isarado uli ang ball valve,umpisahan ng pAandarin, pagmasdan ang pressure pointer, kung gumalaw ba?
@@russelTorino at hindi po nag automatic off deretso lang na umaandar ang motor at steady lang ung pressure gauge (example 30 psi) doon lang sya at di na nag o off.
Yan po ba ay Sa Deep weel humihigop ang inyong motorpump? O Sa nawasa!? Kung sa deepweel maaring Sira o Mayrunng singaw ang foot valve o Sapatilya Sa dulo ng inyong suction pipe, at kung sa nawasa naman humihigop ,Kailangan between motor pump and pressuretank mayron naka,kabit na check valve Sa tubo, kung mayron man naka,kabit pakicheck nyo nalang baka makipalit ,or Sira na, bumalik na ang tubig kaya, Hindi mapupuno ng tubig ang inyong pressure tank, at andar ng andar nalang talaga yan hangang Sa Umiinit ang motorpump.
@@russelTorino deep weel po.
Sundin nyo lang po muna ang Sinabi Ko, na mag drain kayo ng tubig sa inyong pressure tank, baka nakabag lang po yan, at I, observe nyo muna, ang pressure pointer kung gumalaw lagpas Sa 30psi.
Sir bakit kaya mahina ang labas ng tubig namin?
Ano ba dapat normal pressure ng tangke ng tubig? Naka 30 50 po kasi cut on and off.
Yes normally factory tested and set na yan.. Na pressure. Amigo.. Matanong lang po.... Ilang HP ang motor nyo po...? At ilang gallons yan pressure tank nyo?
Magastos sa TEFLON...
bat hindi mo sinabi para sa laundry mga yan?