Foundation Analysis and Design | Lec-04 | SAFE 2016 and Manual | ilustraca | Sandip Deb

Поделиться
HTML-код
  • Опубликовано: 20 окт 2024

Комментарии • 26

  • @ilustraca
    @ilustraca  Год назад +1

    The STRIP WIDTH can be changed for effective depth 1240m considering the method Column width + 2d... I didn't do that as it won't change anything much here. But you can do that and check. The validation for the same will be shown in the next lecture.

  • @blackcomradeYT
    @blackcomradeYT 3 месяца назад

    Bro where can I find the lecture 5?.I need a pile cap design on safe. Nice lecture .thanks🎉

  • @ravishankar.p5542
    @ravishankar.p5542 8 месяцев назад

    why u didnot show the reinforcements in safe software sir like bar size and spacing is it covered in the course ?

  • @nedak-cr5km
    @nedak-cr5km Год назад +1

    Hi, when you got the new amount of effective depth (d), you did not calculate the new value of strip design width?

    • @ilustraca
      @ilustraca  Год назад +1

      Yes you should ... in the video I didn't do that mistakenly... but it has to be done

  • @nedak-cr5km
    @nedak-cr5km Год назад

    Hi, could you plz put more videos about the details and tips for safe 2016 and Etabs 2017? thanks for your time and share your knowledge , you are amazing

  • @GaneshKumar-vi8lo
    @GaneshKumar-vi8lo Год назад

    Instead of increasing further depth pedestal could also be a right option?

  • @anjanadhikary1621
    @anjanadhikary1621 Год назад

    Why are you going to increase the depth of footing? You could increase reinforcement to increase shear capacity.

    • @ilustraca
      @ilustraca  Год назад

      Will not it be more costly?

  • @aamerbaba7026
    @aamerbaba7026 Год назад

    nice session

  • @shareqinamdar8903
    @shareqinamdar8903 Год назад

    Sir, please continue this series

  • @MsRahmania
    @MsRahmania Год назад +1

    Why are you treating one way shear failure as local failure? Is't it fail along whole width? In that case, cant you define a strip width of footing width for the calculation of one way shear?

    • @ilustraca
      @ilustraca  Год назад

      m not considering it as local . I have taken

    • @MsRahmania
      @MsRahmania Год назад

      @@ilustraca if you are taking shear force for entire width where we are expecting one way shear failure per unit width, then didnt we end up in a lesser shear force than 375 kn/m you taken. hope you understand my point. Thanks for replying and videos. Great videos.

    • @ilustraca
      @ilustraca  Год назад +1

      Where did we take for entire width of footing.. ? we took it for column strip only.. that will be always the critical zone.. rest u can check making multiple strips..

  • @niranjanshrestha1147
    @niranjanshrestha1147 Год назад +1

    What will be the difference if we design using FEM instead of strip based design?

    • @ilustraca
      @ilustraca  Год назад

      😊 no difference... in FEM u'll get forces and moments for per meter width at any location.

  • @niranjanshrestha1147
    @niranjanshrestha1147 Год назад +1

    Why do we need to recalculate the bearing capacity limit by adding the value 1.5x (ht. - footing thickness)?
    Can’t we just take 300 KN/m2

    • @ilustraca
      @ilustraca  Год назад

      300kN/m² is Net SBC ... base pressure has to be checked against Gross SBC

  • @kavitakataria14
    @kavitakataria14 Год назад +1

    I think , strip width should be 450+(2*740)=1930 mm

    • @ilustraca
      @ilustraca  Год назад

      Yes yes.. When we changed the depth, that will also change

  • @__saqulainsayeed_SVNIT
    @__saqulainsayeed_SVNIT Год назад

    As for the analysis you have used over burden pressure due to the soil on footing, then why haven't used that load case for the design?

    • @ilustraca
      @ilustraca  Год назад +1

      We'll designing for the worst condition... so we'll not take the advantage of soil load for stability ... also in strength design it has nothing to do.. as the column load and no soil will create more critical condition

    • @__saqulainsayeed_SVNIT
      @__saqulainsayeed_SVNIT Год назад

      @@ilustraca thanks

  • @deepakshrestha7974
    @deepakshrestha7974 Год назад

    How to select the depth of footing with strap beam?.. As it doesn't show the punching.

    • @ilustraca
      @ilustraca  Год назад

      Find shear at d/2 distance from Colum face. Then do Vu/bd to get shear stress. that should be less than the limiting value of 0.25√fck