3.CONTROL EXPERT FUNCTION BLOCK & USE Training/ Tutorial

Поделиться
HTML-код
  • Опубликовано: 11 дек 2024

Комментарии • 23

  • @nomandanish441
    @nomandanish441 Год назад +2

    Really you are the best keep it up very good methodology and tricks

  • @dbreddy5770
    @dbreddy5770 Год назад +2

    👍Super explanation sir. Thank you very much.

  • @technozyt7395
    @technozyt7395 Год назад +1

    Please upload video continuously because your video is very helpful and better understanding

  • @UChannel12
    @UChannel12 Год назад +1

    Thank you sir❤❤❤❤❤

  • @jaythompson5102
    @jaythompson5102 7 месяцев назад

    You're my favourite CE tutorial video creator, I'm more or less able to follow along and I don't even speak your language. Well done!

  • @rakeshshukla7404
    @rakeshshukla7404 Год назад +1

    Supper video

  • @rakeshshukla7404
    @rakeshshukla7404 Год назад +1

    Sir
    Please explain totalizer in control expert and citec SCADA, Shift wise , day wise and month wise

    • @Schneiderautomationsolution
      @Schneiderautomationsolution  Год назад

      Totaliser is the part of logic so I will see in next vedio to cover that point, but citect scada mai day wise shift wise point not clear please elaborate.

  • @dibmondal9201
    @dibmondal9201 Год назад +1

    SIR I CONFIGURED A DNP3 COMMUNICATION BETWEEN PLANT SCADA AND BMXNOR0200. BUT THERE IS A PROBLEM
    BACKFILL SCADA TREND THRROUGH EVENT CAN NOT BE CONFIGURED .
    CAN YOU TELL ME THE CONFIGURATION SETTING FOR THIS.

  • @Worldbigestdemocracy
    @Worldbigestdemocracy 9 месяцев назад

    BMXPRA0100 can generate stop command

    • @Schneiderautomationsolution
      @Schneiderautomationsolution  9 месяцев назад

      pra goes in stop mode some times it happens when any issue occurs. need to check excat issue.

  • @JasmeetDevgun
    @JasmeetDevgun Год назад +1

    Sir mere vaale kaam ki bhi bnado video😂

  • @Worldbigestdemocracy
    @Worldbigestdemocracy 9 месяцев назад

    PRA malfunction side effects on system running equipment

  • @mohanneware9468
    @mohanneware9468 9 месяцев назад

    Sir, ai scalling me 4-20mA pe count 0 to 16000 hai, but hp pump band hone pe 4mA pe 0 count aana chaiye bt nahi aa rha hai, 5000 count aa rhe hai. Aur current band me bhi 19Amp dikha rha hai, ye problem kaise solve hoga sir, toda bataiye sir.

    • @Schneiderautomationsolution
      @Schneiderautomationsolution  9 месяцев назад

      raw count not controlled by you scaling block use to scale raw count into desired values. you need to check wiring .check with multimeter what ma value read in your multimeter in pump off condition if ma is 4 and plc read 500 raw count so need to check your card scaling section minimum value,if min value is zero then you need to replace card. for major issue you can mail me.

  • @ramavtarymc9632
    @ramavtarymc9632 9 месяцев назад +1

    Sir pls apna contact no bataye