How To Install Simpson Strongtie HDU Hold Down Brackets

Поделиться
HTML-код
  • Опубликовано: 14 окт 2024
  • I demonstrate how to install a Simpson Strongtie HDU holdown bracket. I spent a lot of time searching for information about the proper way to install the HDU brackets so you don't have to. Based on what I was able to find on the Simpson Strongtie website, this is what I believe is the correct way to install the HDU holdown brackets. I am not an expert in the construction field, so I do not guarantee the information in this video is accurate.
    Remember to Subscribe!! / @jacobstrianglehomestead
    Jacobs Triangle shirts and other merch!! teespring.com/...
    Facebook: / jacobstriangle
    Pinterest: / pins
    Twitter: / jacobstriangle
    Email: jacobs.triangle@gmail.com
    Intro song: Hooky with Sloane by Bird Creek
    #holdown

Комментарии • 18

  • @benjaminlavigne2272
    @benjaminlavigne2272 11 месяцев назад +3

    Simpson vois their product specs if you impact drill them like that. Need to hand fit like you did, then 1/3 to 1/2 turn with tool. No impact drill is specified on the product sheet.

  • @coloradomountainman8659
    @coloradomountainman8659 2 года назад +2

    Engineering specs on the HDU14's that I have to install on current new construction shows 1/2" space underneath the hold-down. I've also installed 1" bolts into the concrete forms for the wall/stud-pack connection (may be overkill but I had the big bolts in my inventory.)

  • @dmitrykosorukov1010
    @dmitrykosorukov1010 4 месяца назад +1

    No impact gun on the nut. Finger tight plus 1/3 to 1/2 turn with a hand wrench. On your video the anchor bolt turned like ten degrees when you were impact driving that nut. You now need to reinstall the anchor.

  • @vineyardchickshomestead
    @vineyardchickshomestead 2 года назад

    Never heard of these but sounds like one of those things you don't notice but are glad they are there. Things are looking good! Great job!

  • @davidh2049
    @davidh2049 2 года назад +1

    Simpson spec shows only "preservative-treated barrier may be required". It means the HDU should not touch the pressure treated wood. That is all the purpose of the 'air gap". If you tighten the nuts enough, there is no reason it need an air gap to prevent the stud be lifted up. Sometimes it is easier to install the HDU higher. It is an option, not a requirement.

  • @spidy69
    @spidy69 3 года назад +1

    Thanks is there other earthquake etc codes that has to be done?

  • @tara.rankothvlogs
    @tara.rankothvlogs 3 месяца назад

    Thank You!

  • @silverpossum6687
    @silverpossum6687 2 года назад

    Placing the holdown bolt in foundation wall is critical for proper installation to stud attachment

  • @lisandrosanchez123
    @lisandrosanchez123 Год назад

    Your awesome bro I luv you thank you!!!

  • @agirlandhercows501
    @agirlandhercows501 3 года назад +2

    great channel new sub

  • @mz8755
    @mz8755 Год назад

    doesn't look like the bolt is deep enough - the hold down needs to be very deep

  • @jeffmartin95695
    @jeffmartin95695 3 года назад +1

    Better put two of them in the bedroom just to be safe lol

    • @JacobsTriangleHomestead
      @JacobsTriangleHomestead  3 года назад +1

      The engineer must've thought the same thing because both corners on the north wall of the bedroom has one! 😂