OpenVent Bristol V2.0 COVID-19 rapid manufacture emergency ventilator ambu bag ventilation BVM

Поделиться
HTML-код
  • Опубликовано: 23 окт 2024

Комментарии • 30

  • @ghockings
    @ghockings 4 года назад +1

    Good work, this helps understanding of medical problem too.

  • @nevillecreativitymentor
    @nevillecreativitymentor 4 года назад +1

    Absolutely nice. I should know ... i too am working on one!!!

    • @00lewisd1
      @00lewisd1  4 года назад

      Neville Rodrigues I am interested to see your design

    • @nevillecreativitymentor
      @nevillecreativitymentor 4 года назад

      @@00lewisd1 I let go of the Ambu bag device for now .. and am working on another concept which has a reciprocating compressor system ... I live in a small town ..so things are slow ... and right now broke LOL ...so only some 10% of the new design is printed ...hopefully in two to three weeks I should get a semblance of the final prototype .. keeping fingers crossed!!

  • @claudioosorio4847
    @claudioosorio4847 4 года назад +1

    Congratulations. Great job.

  • @kaiser2400
    @kaiser2400 4 года назад +1

    Great Darren 🌹

  • @shahzaibkhan2695
    @shahzaibkhan2695 4 года назад +1

    Keep up good work darren bro

  • @ASHISHMISHRA-nq1bn
    @ASHISHMISHRA-nq1bn 2 года назад

    It’s amazing sir..!! Can you please tell me how you measure the tidel volume that is delivering by this bag at a perticular time

    • @00lewisd1
      @00lewisd1  2 года назад +1

      tidal volume can be caluclated by integrating flow rate over time. My Arduino code is available via the Instructables link

    • @ASHISHMISHRA-nq1bn
      @ASHISHMISHRA-nq1bn 2 года назад

      @@00lewisd1 Thank you so much for replying ❤️
      Can I use BMP280 for differential pressure measuring?

  • @tinupravi1986
    @tinupravi1986 4 года назад +1

    Hi... what is the maximum volume that can be delivered by the DC motor you selected? Thanks

    • @00lewisd1
      @00lewisd1  4 года назад +1

      The motor isn't the limit on tidal volume, it can easily push the bag all the way. The design of the size of the 'fingers' pressing on the bag has more of an effect on volume. I think I managed about 1.2L before I limited it to 800ml

    • @tinupravi1986
      @tinupravi1986 4 года назад +1

      Darren Lewis thanks for the reply. I’ve read the MIT’s e vent design that, pushing the AMBU bag on single side can be resulted in decrease in life of the bag. They are saying it’s better to give push in both sides. Your design is great and minimalist by the way.. 👌👌👌

  • @matiasferreira6909
    @matiasferreira6909 2 года назад

    Hi, what engine do you use?

  • @nonamenofame1297
    @nonamenofame1297 4 года назад

    Dear Darren Lewis,
    Thank ur project.
    I got an error: 'getCurrentM1' was not declared in this scope
    int current = getCurrentM1();
    do u mean: int current = 0; ???
    Please help me.

    • @00lewisd1
      @00lewisd1  4 года назад

      I think you need to add my "analogue filtering" code as another tab in your main code. If you put all the arduino files together in a folder then double click the main file it should automatically add the other arduino files as other tabs

  • @aligul_
    @aligul_ 4 года назад +1

    Great
    Can i use the MPX4250DP 0 250kPa Differential Pressure Sensor instead of using this MPX5010DP Pressure Sensor for flow and pressure

    • @00lewisd1
      @00lewisd1  4 года назад +1

      I have replied to this comment on Insructables

    • @aligul_
      @aligul_ 4 года назад

      Darren Lewis thank you for quick response

  • @arnoldowens8912
    @arnoldowens8912 4 года назад

    Hello, what is the torque rating of the motor, is it a servo, do you have the code for SMIV function? Your source for the motor? Thank you very much.

  • @idrissdoleh5728
    @idrissdoleh5728 3 года назад

    What is the material for the outer shell?

    • @00lewisd1
      @00lewisd1  3 года назад

      8mm acrylic in this test rig. Check the instructables link for full design details

  • @aligul_
    @aligul_ 4 года назад +1

    Why you are only connected the pressure one tube where is othe tube of sensor and or you cut one tube pressure sensor

    • @00lewisd1
      @00lewisd1  4 года назад +1

      I'm not entirely sure what you mean. Sorry, can you rephrase?

    • @aligul_
      @aligul_ 4 года назад

      Darren Lewis i have posted the on instructable

  • @TWTechieTube
    @TWTechieTube 4 года назад +1

    Superb dude
    I want to know some more details in it!

    • @00lewisd1
      @00lewisd1  4 года назад +1

      I have added design details to the description.

    • @aligul_
      @aligul_ 4 года назад

      Darren Lewis MPX4250DP 0 250kPa Differential Pressure Sensor
      Can i use this differential sensor for pressure and flow rate instead of you used in ur ventilator bcoz in my country this one is available right now