Automated Testing in the Medical and Pharmaceutical Industries

Поделиться
HTML-код
  • Опубликовано: 15 сен 2024
  • Depending on the requirements, ZwickRoell testing systems for medical applications can be equipped with manual, semi-automatic or fully automatic specimen feeding, or enable serial or parallel tests.
    𝗔𝘂𝘁𝗼𝗺𝗮𝘁𝗲𝗱 𝘁𝗲𝘀𝘁𝘀
    ▷ Autoinjectors
    ▷ Luer lock connections
    ▷ Pen injectors / insulin pens
    ▷ Residual seal force (RSF)
    ▷ Glide force tests on multiple syringe systems
    ▷ Serial testing of syringes
    ▷ Automated testing of syringes
    𝗔𝘂𝘁𝗼𝗺𝗮𝘁𝗲𝗱 𝘁𝗲𝘀𝘁𝗶𝗻𝗴 𝗼𝗳 𝗮𝘂𝘁𝗼𝗶𝗻𝗷𝗲𝗰𝘁𝗼𝗿𝘀 𝘁𝗼 𝗜𝗦𝗢 𝟭𝟭𝟲𝟬𝟴-𝟱
    When dealing with large production batches, a testing process that saves time and resources is often important. ZwickRoell offers scalable automation solutions for a wide range of requirements.
    The testing assistant roboTest N supports the user with simple applications. Typically, the testing of 30 autoinjectors can be automated with one magazine filling.
    The system can be easily and flexibly adapted to changing test requirements without requiring any special programming knowledge.
    The fully automated robotic testing system roboTest R performs the complete test sequence from removal of the cap, through testing of the autoinjectors, to disposal of the tested specimens and good/bad sorting. To ensure reliable and comparable test results, the measuring equipment is automatically verified on a daily basis (Daily Check). Due to using several autoinjector testing systems, even a large volume of specimens is processed quickly and reliably by roboTest R.
    𝗜𝗦𝗢 𝟴𝟬𝟯𝟲𝟵 - 𝗔𝘂𝘁𝗼𝗺𝗮𝘁𝗲𝗱 𝘁𝗲𝘀𝘁𝗶𝗻𝗴 𝗼𝗳 𝗟𝘂𝗲𝗿 𝗹𝗼𝗰𝗸 𝗰𝗼𝗻𝗻𝗲𝗰𝘁𝗼𝗿𝘀
    When dealing with large production batches, a testing process that saves time and resources is often important. ZwickRoell provides a simple solution for automated testing of Luer lock connectors.
    The testing assistant roboTest N supports the user in performing the test to ISO 80369.Typically, 30 Luer Lock connectors can be tested automatically with one magazine filling. The testing assistant transports the specimen from the magazine to the Luer Lock testing system and positions it in the specimen grips. Here, the thread as well as the seal tightness of the Luer Lock connector are tested. The testing assistant roboTest N then removes the specimen from the machine and returns it to the magazine.
    The system can be easily and flexibly adapted to changing test requirements without requiring any special programming knowledge. For all robotic testing systems, the autoEdition3 automation software is used for information input and control.
    𝗔𝘂𝘁𝗼𝗺𝗮𝘁𝗲𝗱 𝘁𝗲𝘀𝘁𝗶𝗻𝗴 𝗼𝗳 𝗶𝗻𝘀𝘂𝗹𝗶𝗻 𝗽𝗲𝗻𝘀 𝗮𝗻𝗱 𝗽𝗲𝗻 𝗶𝗻𝗷𝗲𝗰𝘁𝗼𝗿𝘀 𝘁𝗼 𝗜𝗦𝗢 𝟭𝟭𝟲𝟬𝟴
    Performing a test on insulin pens using an automated testing system together with the zwickiLine materials testing machine with integrated torsion drive ensures reliable and cost-effective test results . Only one test fixture is needed to check a variety of insulin pen functions. This system allows you to measure the dosage setting, actuation force, glide force, and specified dosage in one continuous process. You can modify and combine the test methods of both test axes to suit your testing needs. The robotic testing system roboTest R is responsible for automated specimen feeding.
    It uses the automation software autoEdition3 to remove insulin pens from the magazine, feed them into the testing machine, and start the test. This minimizes the possibility of inaccurate test results due to operator influence. Our solution makes the test process significantly more efficient thanks to increased specimen throughput. It is also possible to manually test specimens at any time.
    testXpert III together with the Expanded Traceability option to FDA 21 CFR Part 11 make it possible to create documentation for the testing process that is complete and tamper proof.
    𝗔𝘂𝘁𝗼𝗺𝗮𝘁𝗲𝗱 𝘁𝗲𝘀𝘁𝗶𝗻𝗴 𝗼𝗳 𝘀𝘆𝗿𝗶𝗻𝗴𝗲𝘀
    The production in large batches often requires a time- and resource-saving test process. With the testing assistant roboTest N, ZwickRoell offers an easy solution for automated testing of syringes.
    The testing assistant roboTest N supports the user in performing tests to ISO 11040, for example. The system can be used to automatically test a smaller batch of syringes.
    Various test methods, including testing of the plunger glide force and testing of the cap-removal force can be performed with the same machine. To identify the test method currently in use, the testing assistant roboTest N uses a scanner to verify the installed equipment and the specimens in the magazine for consistency before testing the first specimen.
    With the appropriate test arrangement, it is also possible to carry out additional tests described in the ISO 11040 standard.
    The system can be easily and flexibly adapted to changing test requirements without requiring any special programming knowledge. Input and control is realized through the autoEdition3 automation software that is implemented in all automated testing systems.

Комментарии • 2

  • @ZwickRoellTV
    @ZwickRoellTV  Год назад

    More information: www.zwickroell.com/industries/medicalpharmaceutical/automated-testing-medical-industry/

  • @christin9181
    @christin9181 Год назад

    Promo_SM