How to make a 240V 50 amp Digital Voltage Monitor (DIY) Project

Поделиться
HTML-код
  • Опубликовано: 10 сен 2024
  • 240V 50 amp Digital Voltage Monitor (DIY) Project
    Amazon Link for meter amzn.to/3TGDGKW
    Amazon 50 amp plug, male and female link
    www.amazon.com...
    www.amazon.com...

Комментарии • 118

  • @chip2139
    @chip2139 Год назад +7

    I noticed the whiskers sticking out on the terminals. Stranded wire is always twisted clockwise. Hint: Twist the exposed stranded wire counter-clockwise. Then the screw tightens down on the wire, the strands will be drawn in. Problem solved. Power is calculated by multiplying the voltage times the current. The reason for the voltage connection. The things you are calling monitors are called Current Transformers or CT's

  • @itninja9503
    @itninja9503 3 месяца назад +4

    shouldn't you be goin to the Neutral, not the ground for the meters power?

  • @condor5635
    @condor5635 11 дней назад

    Nice but for me mounting this project box all near my electrical panel made more sense. That way it is always close at hand to view and is 'permanent' to the house and out from the elements. It only lights up/turns on when I switch the interlock over to generator power.

  • @rodneygouthier6090
    @rodneygouthier6090 4 месяца назад

    Nice job Gavin.
    Just what I was looking for.
    Thanks again 👍.

  • @SlwRpr
    @SlwRpr 11 месяцев назад

    Hey good job young man.
    I just purchased a gas powered generator, i like your idea and i will have to attempt to make one for mine. I will have to re-watch your video for the instructions.

  • @J.R.F.23
    @J.R.F.23 8 месяцев назад +1

    So I priced it all out and in most cases you would be looking at $70-$100 depending on parts stock (for those that don’t gave any of the parts. I.E.: Work box, pair of monitors, 10/4 wire. Male & Female ends and weatherproof connectors. YES being able to monitor usage would be nice (since many generators don’t have it built in). But us in necessary, due to the fact that most generators usually have overload/over draw protection built in… 🤔

  • @Tom-In-Ga
    @Tom-In-Ga Год назад

    Nice, neat, simple, and it works. Nice job!

  • @BestKaylee
    @BestKaylee 7 месяцев назад

    Thank you so much for the great video. You always have the best information presented in a clear, concise way. Keep up the great work, my only suggestion would be to have someone hold the camera or use a tripod a little more often.

    • @GeneratorReviews
      @GeneratorReviews  7 месяцев назад

      Yeah, sorry about that. I switched to the tripod and 4K camera now learning curve.😅

  • @props-model-shop
    @props-model-shop Год назад +1

    Real nice. Must make one myself.

  • @chrisyerp174
    @chrisyerp174 14 дней назад

    Built many of these boxes in line or on the side of braker pannels but iv never seen hose clamps for lockers lol. NEC turn your head lol

  • @willag1
    @willag1 Год назад +5

    Are those UL approved hose clamps?😆 You may want to find some cable gland connectors.

  • @garden-queen2393
    @garden-queen2393 Год назад

    Nice job. You made it look so easy 👍.

  • @tonyw2641
    @tonyw2641 Год назад +2

    Really nice work, Gavin. Can you provide the links for the box? Also, what tool did you use to make the cut-outs in the faceplate? Thanks.

  • @dontronge9874
    @dontronge9874 Год назад +1

    Very cool. I wonder if I could attach the meter to my 50amp breaker wires and mount the box next to panel to monitor gen usage when using gen and not utility power. That DIY kit would be a big seller man!

    • @GeneratorReviews
      @GeneratorReviews  Год назад +1

      You could make that happen thanks for watching 👍🏾

  • @bullrdr1982
    @bullrdr1982 Месяц назад

    I built a 30a version of this using l14-30r plugs. The displays seem to work, but I am not getting a reading on the watts. The other units display fine (ie amps, frequency, and kWh). Do I have something hooked up wrong?

  • @rockcralwer
    @rockcralwer 3 месяца назад +1

    Man you should sell theses I'd buy one

  • @bluecerulean
    @bluecerulean Год назад +1

    Why do you need two monitors ? Trying to set up something to monitor watts from generator to home . Thanks

    • @GeneratorReviews
      @GeneratorReviews  Год назад +2

      Since the generator has 240 V, you need two monitor, one for each leg easier to keep your generator load balanced.

  • @darrenglynn597
    @darrenglynn597 Год назад

    I would like to know what (wattage ) my industrial fan heater is drawing as it can draw up to (16 amp ) using a (13 amp) plug
    I do not want to make it draw to many amps to do another melt down on the plug. Like what happend on Sunday 25 December at 09:45hts. I was unaware that the thermostat was on it maximum power. Hence the burn out.

  • @Bob-mm9sm
    @Bob-mm9sm Год назад

    I made a unit like this and it did not work on my conventional generator. It worked fine on the Inverter Predator 9500 I have. With the old Powermate generator the display just flickered a little. I'm assuming the power isn't clean/stable enough for device to work. It might with a power conditioner but I won't be getting one to test that. I just thought I'd mention this.

    • @jamesalles139
      @jamesalles139 5 месяцев назад

      yeah, power for the monitor should be taken from a hot and Neutral (white); never Green.

  • @prezzzrock
    @prezzzrock 2 месяца назад

    Would this work for a 11,500 running watts, 14,500 peak watts generator?

  • @jasonhouston7249
    @jasonhouston7249 Год назад

    Just came across this and thinking about it for my Predator 9000, I have a 240v/ 30 amp twist lock, curious if I can use one meter with the clamp around both legs and it will add up the total wattage? Or is it necessary to wire up 2 meters, one for each leg. I'm thinking I'd like it plugged directly into generator, mounted to frame (if it doesnt vibrate loose), then run my cord to inlet at the house. Thoughts?

    • @GeneratorReviews
      @GeneratorReviews  Год назад

      I would have to test this out, but I think if you put one on the neutral wire, it will read both legs

  • @earthenergyhex
    @earthenergyhex Год назад +1

    cool, thx for the video, subscribed

  • @pb4610
    @pb4610 5 месяцев назад +1

    Current should never be on the ground. The meter should be connected to white (neutral).

  • @cliffthomas1389
    @cliffthomas1389 Год назад

    Quick question. Do the wires powering the meter need to be attached to the same wires that you are measuring? I'm installing on my generator and it would be easier to get power to the monitor by using a different source .

    • @GeneratorReviews
      @GeneratorReviews  Год назад +1

      The power of the meter uses you can’t even measure so it should be OK you’re not gonna get a different reading just powered before the meter.

  • @tommartin5217
    @tommartin5217 10 месяцев назад

    How did you strip the insulation off the middle of the cable without nicking the insulation? I am using a piece of 10/4 soow cable.

    • @GeneratorReviews
      @GeneratorReviews  10 месяцев назад +1

      Just use a very sharp razor blade and be extremely careful

  • @gone4days956
    @gone4days956 2 месяца назад

    Gavin would this be the same for a L14-30R 4 prong?

  • @gabrielflores741
    @gabrielflores741 Год назад

    So to find overall power usage (kWh) would you just add the to number together?

  • @mikebutters4540
    @mikebutters4540 5 месяцев назад

    Ok, I did what you showed unfortunately one of my legs always seems to flash when it's plugged in to 240v do you have any suggestions I'm even plugged it into a 240 wall socket can I get one leg that flashes I'd appreciate any comeback from anybody thank you

    • @GeneratorReviews
      @GeneratorReviews  5 месяцев назад

      You must’ve missed something because mine doesn’t do that.

  • @lawrencepikas7519
    @lawrencepikas7519 Год назад

    What gauge wire did you run from the #6 solid wires in the 6 x 6 x 4 box to the monitor?

    • @GeneratorReviews
      @GeneratorReviews  Год назад

      It’s 6 gauge wire I just stripped back the insulation in the middle

  • @richardedwin5980
    @richardedwin5980 7 месяцев назад

    Can I use this same set-up with the predator 9500 even though it doesn’t have a 50amp outlet? I have the 30amp to 50amp splitter cord already. And run a 50amp cord from there to my inlet box.

    • @GeneratorReviews
      @GeneratorReviews  7 месяцев назад

      Yes, you can use the same set up. Just have the 30 amp plugs.

    • @richardedwin5980
      @richardedwin5980 7 месяцев назад

      @@GeneratorReviews I have the 30amp to 50amp splitter cord and connect that to the 50amp cord that runs to my inlet box. Would I still use the 30amp plugs or the 50amp?

  • @growingpains9623
    @growingpains9623 8 месяцев назад

    Would it be safe to use a 50 amp range/dryer cord to bring down the price and cut back on some of the work?

    • @GeneratorReviews
      @GeneratorReviews  8 месяцев назад +1

      That could work as long as it’s a six gauge wire

  • @jorgeesteban3709
    @jorgeesteban3709 2 месяца назад

    Hi Gavin, great video. Can you post a link for the box. It looks like a 6" X 6" X 4".

  • @FirstSuiGeneris
    @FirstSuiGeneris Год назад

    Nice!

  • @gl3882
    @gl3882 Год назад

    Hi Gavin, Thanks for the great video, I was wondering if you've seen a WiFi version of these meters and if so, would they be just as accurate?

  • @tluva1020
    @tluva1020 5 месяцев назад

    Just found your vid. Nice work!!
    Question...
    I'm currently making something similar & would like your thoughts.
    3 meters in a box, on a diy parallel Y cable, that will connect 2 120v generators to a 120v 30a RV outlet.
    A meter measuring the output of each gen, & the 3rd meter measuring the combined output of the two gens.
    The idea is if I mix 2 different gens, like a 2,000w & a 3,500w, or a 1,600w & 2,200w, I could see if they are sharing the same load equally or if the bigger gen is carrying more load as it should.
    I'm wondering if the meter readings will be affected incorrectly by back feeding each other since essentially they're all on the same circuit leg. What do you think?Thx!

    • @GeneratorReviews
      @GeneratorReviews  5 месяцев назад +1

      That should work fine I don’t see any issues with your idea 💡 good luck 👍🏾

    • @tluva1020
      @tluva1020 5 месяцев назад

      ​@@GeneratorReviews thx 4 the reply. I'll give it a shot!

  • @mrrickcrushing
    @mrrickcrushing Год назад +2

    Hi, Gavin, great instructions, I built this last night but I am going to use it for a more or less permanent mount beside my main panel so I can watch my gen when it is under load. I intend to put the conductors around each leg in the internal portion of the inlet box from outside, my question is: I need to add about two feet to the black/red wires from each conductor...using the same gauge wire, do you think that will induce delta into the accuracy of the readings or will that still be ok? I am thinking ok but never hurts to ask, lol. Thanks!

    • @GeneratorReviews
      @GeneratorReviews  Год назад +1

      You should be perfectly fine! 2 feet not gonna change anything
      That’s pretty awesome you made one. Thanks 👍🏾💯

  • @holdenbreau7187
    @holdenbreau7187 Год назад

    What is your background are you electronics or electrical tech? Also did you ever look into a 100 amp device?

  • @cartrip2559
    @cartrip2559 11 месяцев назад

    Great video. I am just subscribed. I have the generator connected to my main electrical house panel via gen inlet and 50 amp breaker. Can I use the 2 monitor clamps on that 50 amp breaker wires? I could then connect the monitor ground to the panel ground bus. Where would I connect monitor power? I plan to have the 2 monitor displays in the house, so should I power the monitors using a regular wall outlet? Thanks for your response.

    • @GeneratorReviews
      @GeneratorReviews  11 месяцев назад

      Yes you can power the monitor from a separate outlet it would work 👍🏾

    • @cartrip2559
      @cartrip2559 11 месяцев назад

      @@GeneratorReviews So I can have the 2 clamps on the 2 wires on the 50 amp breaker inside my panel and then have the 2 monitors inside my house. I can probably cut and modify a regular extension cord with hot, neutral, ground, and connect the monitors to a regular wall outlet. Anything that you can think of that I am forgetting? Can the monitors handle 110v coming to it?

  • @christurner5473
    @christurner5473 Год назад

    That meter is bad ass, when you start selling your shirts you totally got start selling these meters to. If you were gonna start selling those how much would you sell them for. Could you use those on any generator??

    • @GeneratorReviews
      @GeneratorReviews  Год назад +3

      Hey Chris
      Definitely I will be making those I’ll sell them as a kit DIY kit
      Haven’t thought of a price yet, but it wouldn’t be that much

  • @angeloguzman1426
    @angeloguzman1426 Год назад

    Hello Gavin, thanks for the video. I built one this weekend. It looks like it’s working, but I have a question. I connected to a Predator 9500 using a 25’ 10AWG cable. Interlock, etc. No AC or other heavy loads. The top meter read 123 Volts, 6.591 amps and 563 watts. I’m not an electrician, but OHM’s law tells me the watts should be 810 not 563. The bottom meter had similar readings. Also, the top meter had PF reading of .61 and the bottom meter read .50 PF. That should ideally read close to 1.00 and .90, or thereabouts. Does the PF affect wattage output? To any electrician out there, what does a low PF in this case mean? Are my wires loose? Any help or observations would be greatly appreciated. Thanks

    • @GeneratorReviews
      @GeneratorReviews  Год назад +1

      Just make sure you orientated your clamps the right direction

    • @angeloguzman1426
      @angeloguzman1426 Год назад

      These clamps don’t have an arrow to indicate orientation.

    • @angeloguzman1426
      @angeloguzman1426 Год назад

      Hey, even though I did see any arrows which would point to a proper orientation, I did have mine in placed in opposite directions. Once I changed one of them and both were oriented toward the same direction, problem solved. Thanks, much appreciated. The PF reading is now 1.0. @@GeneratorReviews

  • @waterboy74
    @waterboy74 Год назад

    Shouldn’t you have connected the meter power to the neutral instead of ground ? Aren’t you using ground as a return for the meter power the way you did it?

    • @GeneratorReviews
      @GeneratorReviews  Год назад

      You have to connect it to the ground because connected to the neutral is for your 240 V reading

  • @tluva1020
    @tluva1020 10 месяцев назад +1

    Use proper strain relief

    • @GeneratorReviews
      @GeneratorReviews  10 месяцев назад

      Yes, I just ordered the correct wire clamps This was done last minute. I plan on doing an updated video.

  • @GAMINGKID12147
    @GAMINGKID12147 Год назад

    will this tell me a rolling use for a total of lets use an example of 30 days? I am trying to see how much power a 5th wheel is using so I can charge them for total KWH. thank you

    • @GeneratorReviews
      @GeneratorReviews  Год назад +1

      Yes it has a meter that counts total kWh used and it is resettable

  • @mikebutters4540
    @mikebutters4540 Год назад

    I'm sorry but I'm done exactly what you've done and my monitors don't seem to pick up any current and when I have the monitors in place like you do I'm only getting a quarter of the bolts out but it's a funny thing to monitors are sometimes working and sometimes not working and this is the second set of monitors I've tried.
    What am I doing wrong.
    Sorry smartphone at put the word bolt but I said volt.

    • @GeneratorReviews
      @GeneratorReviews  Год назад

      They are direction sensitive you have to make sure the monitors are facing the same way

  • @browsedeweb8834
    @browsedeweb8834 Год назад +4

    Shouldn't the power to the meters be the hot and neutral? Neutral is current carrying where ground is not, and for accurate power readings, you want to measure voltage across the load. See the 5th diagram down in the Amazon link you posted up top.

    • @GeneratorReviews
      @GeneratorReviews  Год назад

      Most generators are bonded, the ground and neutral wire coming from the same place and you have to get your power reading from your hot wire
      I guess that’s why I showed a test. It works great and it goes back to zero with no load.

    • @browsedeweb8834
      @browsedeweb8834 Год назад +2

      @@GeneratorReviews My Honda is floating neutral. Probably no big deal, but as an engineer I'd still follow the wiring diagram since that is the recommended method.

    • @busterhyman6633
      @busterhyman6633 Год назад +1

      @@GeneratorReviews So if you unbond the generator to backfeed an inlet would you do hot and neutral?

  • @RobertJohnVenable
    @RobertJohnVenable Год назад

    Awesome, might do this myself

  • @robertkinnan3478
    @robertkinnan3478 Год назад

    Do you think this could be adapted safely to measure my main panel instead of a generator?

    • @GeneratorReviews
      @GeneratorReviews  Год назад

      They have one that works great for what you need

    • @robertkinnan3478
      @robertkinnan3478 Год назад

      @@GeneratorReviews I purchased the ones you show on this video. Do you have a link to what you think would work?

  • @TheHelimechanic
    @TheHelimechanic Год назад

    what gauge wire are you using for the power monitor wires?

  • @darrenglynn597
    @darrenglynn597 Год назад

    What meters have the clamp (iron cores) can I get them from Amazon.

  • @mikemurray8423
    @mikemurray8423 Год назад

    Just saw the A1volt 10000 watt invertor, what do you think? Review...

    • @GeneratorReviews
      @GeneratorReviews  Год назад

      I just wish it had a 50 amp plug for a 10000 watts generator

    • @mikemurray8423
      @mikemurray8423 Год назад

      @@GeneratorReviews that's what I thought, love your videos

  • @JavierRivera
    @JavierRivera Год назад

    Hey. Is that an adapter cable that came already with the connectors or is a soow 6/4 cable and you added the connectors. If it is a adapter that came all in one can you provide the link?

    • @GeneratorReviews
      @GeneratorReviews  Год назад

      Hey Javier
      What’s up buddy
      All the pieces came separately. I’m going to add all the links.

    • @JavierRivera
      @JavierRivera Год назад +1

      @@GeneratorReviews thank you. The Hurricane Ian came by my house. I lost power and I was able to power my whole house with the GM9000iED. Stove is gas, dryer gas, 2 AC units- 3ton and 2ton. With both ac running, refrigerator and anything else that is normally connected like internet etc I was running the generator at 4,800 watts. 💪🏼

    • @GeneratorReviews
      @GeneratorReviews  Год назад

      @@JavierRivera nice 👍🏾

    • @sh839c
      @sh839c Год назад

      @@JavierRivera So does the GM 9000iED put out 240 volt for the ac units?.

    • @JavierRivera
      @JavierRivera Год назад

      @@sh839c that is correct. 240v and 50amp. I have a few videos on my channel

  • @twsconsulting
    @twsconsulting Год назад

    Why green instead of white. I think power should be taken from line to neutral, not ground to line......It is true that neutral and ground are bonded in some installations, but not all....

    • @GeneratorReviews
      @GeneratorReviews  Год назад

      If you take it from the neutral wire your monitor will never show zero because it always measures the power from the monitor.
      RVs, transfer switches and most generators are bonded

  • @richardedwin5980
    @richardedwin5980 7 месяцев назад

    Is the junction box metal or pvc?

  • @ceebee4334
    @ceebee4334 Год назад

    Can you use 10/4 SOOW cable for this?

    • @rjen34772
      @rjen34772 Год назад +3

      10 gauge wire would only be good for up to 30 amps

    • @ceebee4334
      @ceebee4334 Год назад +2

      Agreed. My setup is all 30 amps from the generator to the house generator inlet so I can duplicate this setup Gavin has outlined but with 10/4 SOOW I am assuming.
      I just want to be able to monitor the 2 legs off of my 240 30amp outlet…..and want to do it safely.

  • @valentincampos8436
    @valentincampos8436 Год назад

    Could you use only one monitor with thinner wire?

  • @bluecerulean
    @bluecerulean Год назад

    Also, I have a RVGUARD 4 Prong 30 Amp 50 Foot Generator Extension Cord from Amazon that I connect to my generator and home do I follow same setup? Thanks In advance. Can I just pay you to make one? Lol😅

    • @GeneratorReviews
      @GeneratorReviews  Год назад +1

      I can make you one that’s not a problem

    • @bluecerulean
      @bluecerulean Год назад

      Not sure how to get you my contact info I think it keeps getting deleted from here

    • @bluecerulean
      @bluecerulean Год назад

      @@GeneratorReviews figured out how to get your email from the desktop just send you my info. Thank you sir !

  • @brandongolder4492
    @brandongolder4492 11 месяцев назад

    Does this calculate kilowatt hours?