How to Test Air Conditioner sensor / Easy to Check Air Temperatur & Coil sensor with cool water/HVAC
HTML-код
- Опубликовано: 25 июл 2024
- AC SENSOR
How to Test Air Conditioner sensor
Easy to Check Air Temperatur & Coil sensor with cool water
Inverter ac are now inverter ac sensor
how to analyse the sensor complaint
sensor check with cool and hot water
ac no cooling problem
air conditioner sensor testing best trick with digital multi meter
#CHILL #TECH #AIRCON
Subscribe my RUclips channel link
/ @mohammedsiddiq.s1111
How to do Air Conditions filter service in home
• How to do Air Conditio...
Air Conditioning cycle working principle in Tamil
• Air Conditioning cycle...
Ac outdoor Fan motor Connection of 4 wire
• Ac outdoor Fan motor C...
AIR CONDITIONER RUNS BUT DOESN'T COOL
*sometimes the air conditioner can run and you don't feel any cool air.
-it is important to check the therostat although it might not be the problem.
-check whether the condenser is dirty,clean it and remove any dirt.
-inadequate amount of refrigerant in the system can be the cause of this problem and it can be addressed by a professiona.
-check the air compressor whether it is running by listening to it and checking for the power light.
-check the compressor or condenser coil whethe it is blocked or damaged
Very clear demo and super 👌
Electronic companance banfits bathi oru video bannunga Ac la vara parts Spilt,cassat,Fcu,Vrf
fine demo thankyou.
Super really great 👍
Supper bro ❤
Super bro
Very clear explanation. I had a experience like in lecture's teaching. Thank you.
TQ 😍
❤👍 thanks
Nice explanation, we have old Panasonic ac, in this no display provided ,can we fix separate display for knowing temperature
Clear explanation 👍 Good work. But please correct clamp meter not it's multimeter. I think you know that clamp and multimeter different.
Ethu pol niraiya video podunga Ji, thanks 🙏
OK 😊
Good
Superb Macha
TQ FRIEND 😍
Good explanation do well my dear
TQ DEAR🥰
Super bro...
TQ Anna 😍
I support bro. Super
TQ BRO😍😍😍
நன்றி
Nice! Bro,. Please upload trouble shoot about inverter ac.
Ok bro I will trying 😊
One suggestion: Please mention “in tamil” in every video you made in tamil. Because oru vela hindi ah irukumo.. seri irundhutu potum nu tha ulla vandhen. But tamil la irundha odane I am very happy. So please mention it.
Super❤
THANKS YOU
Super bro. Onida inverter split AC E5 next 5E error code what is the complaint how to solve the problem
Super
TQ 😍
super RUclips enjoy
Super bro my ac EC error code what is this tell me bro
I support ji
TQ ANNA😍
Bro remote and indoor unit sensor check
Hi bro my one year old lg 1.5ton convertible AC is not colling to my set temperature (eg) if i set my ac at 22 even after 8hrs of running room temperature is remain in 28°
Bro
Inverter split AC ka indoor aur Temprature sensor aur coil sensor ka value kitna hona chahiye.please reply
Super bro and what's happened f3 error starting time 2 r 3 times showing after working good voltas inverter split ac
Outdoor unit pcb IBM module fault bro
Bro coil sensor and room sensor value renduma 7.5 sama irrukuma
Bro split ac oru 5 minutes run anathuku apuram.. Automatica off aguthu.. Then marupadiyum running agula appo enna problem bro ithu..
Sensor enna rate varum sir
👌Super bro, my AC voltas 1.5 ton coil sensor is dead, but which value sensor I have to change 10k, 15k, 20k? Please tell me, thank you
8K to 10k bro
TQ 😊
Hii bro godrej ac la work aagite irukum bodhu sudden ah light twice blink aagitu E2 nu display la kaatuthu apdiye wings close aaiduthu......user manual la the fault of indoor pipe temperature sensor nu iruku ithu epdi solve pananum ??
Indoor sensor is fault you change same value sensor
Sir ethu multimeter
Hi bro AC compressor continuesly running not cut off
Bro my normal split ac (Not inverter type) automatically changing modes and switched off automatically.. for the past 2 days.. Its running and cooling also coming but suddenly modes are changing and switched off. What may be the problem.. Any solution??
Bro you check indoor PCB board
Hi bro
Hi bro
Haier service sensor cost they cost 950? Is the real price?
O.k
😍
Athu clamp meter illa multi meter correcting from 🇲🇾
MY AC NOT ON , WHAT PROBLEM BROTHER
Hmm call me 9715181086
Super bro
Super bro
TQ 😍