My Exide T-1500 145 Ah battery, which is under warranty, is not providing the expected backup time. I had it replaced, but the new battery has the same issue. Even though the battery's specific gravity is normal, it still doesn't provide more than 2 hours of backup with a load of just one 30-watt fan and four LED savers. My setup is as follows: Inverter: 1KVA HVS 1214 SCC Solar Panels: Four 260-watt panels Panel Configuration: Series-Parallel Total Current: 28.2 amperes Total Voltage: 49 volts Battery: 145 Ah Load: 150-200 watts Steps Taken: Battery Replacement: I replaced the battery under warranty, but the new battery exhibits the same issue. Gravity Check: I checked the battery's specific gravity, and it's within the normal range. Load Testing: I tested the backup time with a minimal load of one 30-watt fan and four LED savers, and it still doesn't last more than 2 hours. Request for Assistance: I kindly request your assistance in troubleshooting this issue and determining the cause of the reduced backup time. I'm concerned about the battery's performance, even though it's a new one under warranty. Please advise on the next steps to resolve this matter. Additional Notes: I have ensured all connections are clean and tight. There are no other hidden loads connected to the battery. Thank you for your attention to this matter. I look forward to your prompt response and guidance.
@@MrAmirbrohi Same mamla mry sath b tha Main ny Landday k RUclipsrs ki batain sun kr Exide TR1800 k float charging voltage 13.8 rakhy huay thy jb k Battery case py 14.40 thy main ny 14.40 kr deay hain Main JinKo ki 575W ki 2 Plates 80A Simtek MPPT k sath use kr rha houn At Night Simtek ka e 30A charger jo Wapda sy charge krta hy to vo use kr rha houn Abi 6 sy 7 ghanty ka backup mil rha hy 100W sy 150W main
Bilkul teek hay, many phonex TX3500 18 months pehly lee thi, gravity b teek rakhi abhi tak, aur charging b 30Amp. Abhi aik cell harab howa hay aur backup nahi day rahi. Mazay ki baat cell b repair nahi hoga , means complete discard 😢
Maa Sha Allah.Mera Piyara Bhai. Allah pak AAP ko Deen o Dunia ki bhlayan atta farmay Aameen Allah pak AAP k karobar main barkat dy. Bhai Jan APC ups k bary video bnain or jisk Sath mppt charge controller Laga k solar k Sath connect kiya ja skta hy. Bjay costly inverter lainy k. 3000 waat TK 24 volt system bnany kliy.or kiya APC ups k Sath tubular battery charge ho jati hy
Ns 1000 watt inverter jis mai 70 ampere ka mppt ata hai ya Trion 1202 os mai bhe 70 ampere ka mppt ata hai kia os per Tubular battery use ker sakte hain
I have fronus xeon plus 2000, 1 saal mai 2 tubular batteries kharab ho chuki hai overcharge ki waja se Exide tr 2500. Pls suggest bulk & float settings. Currently bulk is set to 14.6 & float to 13.6
Asalam alaikum brother guide me mery pas ups homage model 1011scc hai battery AGS Tall1800 12v 140AH abhi 4 din pehly kharedi plz bataen tek kam kry gi Allah aap ko slamat rakhy amin
Assalam walekum Sar ji Humne long life inverter 3 Kilowatt ka system lagaya hai Jiske Sath tubular battery TX 1600 Lagai hai Unka backup kam ho gaya uski setting to bata de sar
Assalam Walekum bhai hamare pass long life 3 Kilowatt ka inverter hai Jiske Sath Humne theek se 1600 battery Lagai hai Unka backup jo hai na Sar kam a raha hai koi setting ke bare mein Bata De long life ki reply kar dena Sar ji Allah aapko Khush Rakhe
Sir how to contact you Hamaray masjid me 5.2 kw inverex laga hai 570 w k 8 panel lagay hain ags sp tall 1800 battery 4 lagay hain masjid me kam sahi nhi chal raha please reply help karen Allah apka bala karen aameen reply must sir Thanks
sir mary pas osaka taltublar 1800 bettery hy abi bs 7 month hoy hy 400 waat k load pr just 30 min backup dy rhi hy phaly ups us ko 25 ampire pr 3 ganty charge krta tha ab just 15 minute charge krny ky bad bettery full ka option dy kr charge krna band kr data hy mai ny simtak ka new charger lyea but wo charger b 30 min charge krny ky bad bettery full ka option dy kr charging stop kr data hy bettery charge ni ho pa rhi tbi backup ni mil rha mai ab kya kro pzz help
@@umairkazmi733 bhai mara problem solve ho gya hy mai ny sari rat tanger pr lgwai thi battery ab 22 ampire py 3 ganty tk charge hoti hy wrna phaly 15 min charge ho kr band ho jati thi charging ap b tanger pr lgwaoo ake rat
aoa bhai 4mm wire and 6mm wire par video banaen 10 panels serires main 14amp max k liay konsi wire use karain gay thoury kahti hai 4mm 25 to 30 amp k liay kafi hai please video banaen
Simple rule hai jo rheory kahti hay usko 50% pe le kar practically use karo For example agar aik cable 50A tak carry kar sakta hai to ap usko 25A se zyada ke liye use na karein
سر میں نےMaxpower pv7000pro لگوایاہے ساتھPhonix tublar 2500 لگوائ ہیں jinko 555 14plate کےساتھ لیکن رات کو بیٹری کا بیک اپ 5پنکھے اور ایک فریج کے ساتھ صرف 2گھنٹے ارہا ہے
Tubular battery 🔋 galti sr bi na lena, tx 1800, 185 ah li thi ghatia aj tak charge nai huwi pese bekar na lena,,, normal osaka lelo without tubular .. wo best ha,, hamara inverter inverex xtron 1200 ha 1kw ka.....
سر 580 واٹ جنکو N ٹائپ کے 2 سولر پینل ہیں، 3 پنکھوں خورشید ڈی سی فین اور 2 لائٹس ہیں، اس کےلئے فورس کمپنی کا ایم پی پی ٹی لینے کا ارادہ ہے، اب بتائیں کہ اس کےلئے کونسی بیٹری لوں ٹیوبلر یا سادہ؟
@@zsfakhar1904 سر جو لوڈ اوپر بتا چکا ہوں اس کےلئے Exide hp 200 ماڈل جسکا ایمپیر ہاور 130 ہے ٹھیک رہی گی یا اس سے بڑی، اگر پوری رات کےلئے بیک اپ لینا ہو۔ کیونکہ میں بجلی پر انحصار ختم کرنا چاہتا ہوں۔
Yah baat sahi ha ma na 2 year phalay tublar battery lagahi 1 year ma khatam phir ags tublar battery lagahi woh bhi 1 year bass in dono ka backup nahi ha sahi ma kahan ga normal battery lan
سلام۔ میرا 450 واٹ کے دو سولر پینل کا ڈی سی سسٹم ہے۔ ٹوٹل 900 واٹ۔ 60amp کا simtek کا mppt چاجر ہے۔ کیا یہ چارجر ان سولر پلیٹ کے ساتھ TX 1800 کی ٹال ٹیوبلر بیٹری کو چارج کرے گا؟
جناب اکثر گھروں میں ups لگا ہے اور انورٹر انورٹر کی باتیں کر رہے ہیں ہم خود لوکل ups اور 2 بڑی پلیٹس پہ یہی ٹیوبلر بیٹری استعمال کر رہے ہیں کیونکہ ups میں bulk چارجنگ کی option نہیں ہوتی سارا دن تو گزارا چل جاتا ہے لیکن شام کو یہ بیٹری فل ہونے کے باوجود 2 یا اڑھائی گھنٹے سے زیادہ 300 واٹ کے لوڈ پہ بیک اپ نہیں دیتی، بہت بے کار بیٹری ہے 56 ہزار روپے ضائع ہوگئے بہت افسوس ہوا
Assalamoalikum bahi mery paas 550 w k 2 panels hai or 60 amp k force Mppt hai DC load run karna hai.DC load 3fans and 1 invertor freezer hai .mei tx 1800 tubeler battery lagasakta hun.please reply
اسلام علیکم بھائی آپ ٹیوبلر بیٹری کی گریوٹی کے بارے میں جتنی بھی ویڈیوز بنا رہے ہیں میں نے آپ کی ساری ویڈیوز دیکھی ہیں مجھے سمجھ نہیں آ رہی کہ ٹیوبلر بیٹری کے amp اور bulk volt اور flot volt کتنے رکھنے چاہیے جیسا کہ میرے پاس crown کا 3.6 Xavier IIکا انورٹر ہے اور PHONEX کی TX3500 280amp کی دو بیٹری لگی ہیں یعنی 24 وولٹ سسٹم ہے مسئلہ یہ ہے کہ بیٹریوں کی گریوٹی 11.50 سے اوپر نہیں جاتی 31.5 وولٹ پر90 منٹ equalization کرنے سے گریوٹی تو پوری ہو جاتی ہے لیکن اگلے دن پھر 11.50 پر آ جاتی ہے بیٹری چارجنگ amp 30 Bulk volt 29.2 Flot volt 27.0 رکھے ہوئے ہیں سسٹم کو لگائے ہوئے 1 ماہ ہوا ہے Battery discharge 20 amp سے زیادہ نہیں ہوتی کیونکہ ہمارا لوڈ ہی 20 apm تک ہے دن کو بھی لوڈ زیادہ نہیں ہوتا ضرورت سے زیادہ بڑا سسٹم لگا ہے 545 کے 8 پینل لگے ہیں جو ضرورت سے زیادہ ہیں مسئلہ گریوٹی نہ پوری ہونے کا ہے حل بتائیں؟ ظاہر سی بات ہے کہ ہر روز تو بیٹری کو equalize تو نہیں کیا جاسکتا؟ نوٹ : بیٹری کی وائر زیادہ لمبی بھی نہیں ہے اور 25mm لگی ہوئی ہے تمام parameter پورے ہیں ہم واپڈا کو مکمل بند رکھنا چاہتے ہیں
میرے گھر میں 3KW کا سولر سسٹم لگا ہوا ہے۔ اس کے ساتھ اوساکا کمپنی کی 185 ایمپئیر والی دو بیٹریز لگی ہوئی ہے۔ میری بیٹری کے ساتھ بھی یہی مسلہ ہے، میں بھی جب بیٹری سے بیک اپ لیتا ہوں تو اگلے دن چارجنگ کے باوجود بیٹری کی گریویٹی لو رہتی ہے اگر میں بیٹری سے بیک اپ نہ لوں تو ایک دو دن میں بیٹری کی گریویٹی خود ہی پوری ہو جاتی ہے۔ حالانکہ میں نے کبھی بھی بیٹری کو فول ڈسچارج نہیں کیا نہ ہی اس پر بہت زیادہ لوڈ ہوتا ہے زیادہ سے زیادہ لوڈ 20 ایمپئیر تک ہوتا ہے۔بلک اور فلوٹنگ وولٹیج زیادہ کرکے بھی دیکھے ہیں لیکن کوئی فرق نہیں پڑا۔ بلک وولٹیج 2۔29 اعشاریہ دو ہیں فلوٹنگ وولٹیج 8۔28 پر سیٹ ہیں۔ اگر ہم بیٹری سے بیک اپ نہیں لے سکتے تو ایسی مہنگی بیٹریز خریدنے کا کیا فائدہ۔ اگر کسی بھائی کے پاس اس مسئلے کا حل ہے تو مجھے گائیڈ کریں۔
Bhai 48V system me inverter ke cut off 42v ha... Laikin jub b discharge kertay hain to 1 battery 9 volt tak b chali jati ha... Aisa kiun hota ha jab k supply cut off b nhi hoti
Bhaai wo is liye hota ha , agr ap ne cut off 42v rkha ha , inverter us se backup power lena chor deta ha, lekin wapda pe shift ho ke bhi inverter battery se power leta hai. Means inverter on rehta ha wo 50watt battery se leta rehta hai, is trah se battery apki dead hojati hai
Datou Boss 2000W Pure Sine Wave Tubular k sath lgaya ja skta hy ??? Car Inverter hy Europeon Standard wala . Battery ka talaq MPPT ki charging sy hy ya Inverter sy hota hy ?????
Zbrdst sir
DC solar system banane k lie simtek 60amp charge controller k sath kounsi battery lagani chahea
tubular ya simple lead acid
ماشاءاللہ زبردست
ماشاءاللہ بہت خوب مقبول اللہ تعالیٰ آپ کو کامیاب کرے آمین ثم آمین یا رب العالمین
❤ماشاءاللہ❤
My Exide T-1500 145 Ah battery, which is under warranty, is not providing the expected backup time. I had it replaced, but the new battery has the same issue. Even though the battery's specific gravity is normal, it still doesn't provide more than 2 hours of backup with a load of just one 30-watt fan and four LED savers.
My setup is as follows:
Inverter: 1KVA HVS 1214 SCC
Solar Panels: Four 260-watt panels
Panel Configuration: Series-Parallel
Total Current: 28.2 amperes
Total Voltage: 49 volts
Battery: 145 Ah
Load: 150-200 watts
Steps Taken:
Battery Replacement: I replaced the battery under warranty, but the new battery exhibits the same issue.
Gravity Check: I checked the battery's specific gravity, and it's within the normal range.
Load Testing: I tested the backup time with a minimal load of one 30-watt fan and four LED savers, and it still doesn't last more than 2 hours.
Request for Assistance:
I kindly request your assistance in troubleshooting this issue and determining the cause of the reduced backup time. I'm concerned about the battery's performance, even though it's a new one under warranty. Please advise on the next steps to resolve this matter.
Additional Notes:
I have ensured all connections are clean and tight.
There are no other hidden loads connected to the battery.
Thank you for your attention to this matter. I look forward to your prompt response and guidance.
Why 49 volts?
i also face same issue but i have tubler battery Tx1800 with inverex X1200
Set the recommended battery settings
For Exide you may set
Charging curent 15 A
Bulk charging 14.8
Float charging 14.4
You wil get good backup.
@@MrAmirbrohi
Same mamla mry sath b tha
Main ny Landday k RUclipsrs ki batain sun kr
Exide TR1800 k float charging voltage 13.8 rakhy huay thy jb k Battery case py 14.40 thy main ny 14.40 kr deay hain
Main JinKo ki 575W ki 2 Plates 80A Simtek MPPT k sath use kr rha houn
At Night Simtek ka e 30A charger jo Wapda sy charge krta hy to vo use kr rha houn
Abi 6 sy 7 ghanty ka backup mil rha hy
100W sy 150W main
شکریہ
Simple mppt (faisal pakteck) ke sath konse battery lagaen
Good information ❤❤❤
❤❤❤ good information sir 👍
High aur low charging viltage bar bar kehnay ke bajay app charge ke quatity bata daitay ! Yani kitni ?
ٹیبلر بیٹری کا کوئی مقابلہ نہں۔
Bilkul teek hay, many phonex TX3500 18 months pehly lee thi, gravity b teek rakhi abhi tak, aur charging b 30Amp.
Abhi aik cell harab howa hay aur backup nahi day rahi.
Mazay ki baat cell b repair nahi hoga , means complete discard 😢
Charging amps buhat zayada hen, minimum 18 amps rakho if possible verna 20 enough hen
@@arif6780
Simtek MPPT main to Amperes up down krny ka option e nhn hota to phr banda kya kray ????
Mashalag
Ayam mppt charge controller k sath tubular battery lagani chahiye?
Bhai battery charge kerney keleye Amp chaiye ya volts?
Amp or Volts dono ...
For example for 200ah battery safe charging Range is 13 to 15v ( depand on the type of battery ) and 20 amps.
Inverex 2500-24 premium model k sath tubeller battery laga saktay hain?
Sir hmara fronus pv 3200 ka inverter h tall tubler bettery lagi h 2 mjhe ampire btaye kitna rakho charg k lye
Tubular battery MPPt simtk 100 ampr wla k st attach kar skta Hain kia ???
Ups k liye konsi battery sai hai 1000watt k liye
Kita gam simple ups k sath tubler battry use kr sakty hain to achi life r acha backup mill sakta ha 1000watt ups
Nice information
pv 5200 k sath laga sakty hn ye fronus ka hy
Men 3 se 4 panels attach karon ga matlb 2 kw
Pv 3200 fruons k sath tubular lag skti h?
bot acha brif karta ha ge
Asslam o alaikum bhai ziewnic pv 5000 model k sath tublar laga skte hain kia vo 4 kv ka hai? Kindly bta dein i am your big fan
Sir Simtek 70amp k sath tublar battery chal jye gi??? Main ny osaka 1800 purchase kar li hai
I have same question. Or kitny time mae battery full charge hogi?
Aoa.can I use teublar bat for home age 1.8 kw solar inver.
Bro has a masters in battery 💀
U2 4.09 inverter inverex ke screen pa sho ho rahy hin Rs ka Kya mttlab hy
Kya Simtek mppt k sath Tall tublar lagani chahye ? Complete DC system k liye ? Plz guide kar dein
Zaror lekin 1000 watt plate k sath
Maa Sha Allah.Mera Piyara Bhai. Allah pak AAP ko Deen o Dunia ki bhlayan atta farmay Aameen Allah pak AAP k karobar main barkat dy. Bhai Jan APC ups k bary video bnain or jisk Sath mppt charge controller Laga k solar k Sath connect kiya ja skta hy. Bjay costly inverter lainy k. 3000 waat TK 24 volt system bnany kliy.or kiya APC ups k Sath tubular battery charge ho jati hy
What kind of battery can use with Inverex Veryon II 2.5Kw(24v) ( Tubular , Deep Cycle ,Tall battery or just Regular Plates Battery) need your advice.
Assalamu alaikum, kindly ongrid inverter par video banaen shukria
Tall tubular C10 Solar battery ke bulk charging aur float charging kitni rakhni chahiye Sir
Ns 1000 watt inverter jis mai 70 ampere ka mppt ata hai ya Trion 1202 os mai bhe 70 ampere ka mppt ata hai kia os per Tubular battery use ker sakte hain
کوشش کریں کہ سمپل بیٹری استعمال کریں ۔۔ ٹیوبلر بیٹری کا بیک اپ اچھا نہیں۔۔
I have fronus xeon plus 2000, 1 saal mai 2 tubular batteries kharab ho chuki hai overcharge ki waja se Exide tr 2500. Pls suggest bulk & float settings.
Currently bulk is set to 14.6 & float to 13.6
dc ka lia kon c battre ha mppa ha mara ps 80amrpr ma
Asalam alaikum brother guide me mery pas ups homage model 1011scc hai battery AGS Tall1800 12v 140AH abhi 4 din pehly kharedi plz bataen tek kam kry gi Allah aap ko slamat rakhy amin
Assalam walekum Sar ji Humne long life inverter 3 Kilowatt ka system lagaya hai Jiske Sath tubular battery TX 1600 Lagai hai Unka backup kam ho gaya uski setting to bata de sar
Assalam Walekum bhai hamare pass long life 3 Kilowatt ka inverter hai Jiske Sath Humne theek se 1600 battery Lagai hai Unka backup jo hai na Sar kam a raha hai koi setting ke bare mein Bata De long life ki reply kar dena Sar ji Allah aapko Khush Rakhe
Hawk Ht 1800 ki setting bta dain inverex nitrox k lijye
Battery per 20hr likha hota hai is ka matlab kya hai plz reply
Sir how to contact you
Hamaray masjid me 5.2 kw inverex laga hai 570 w k 8 panel lagay hain ags sp tall 1800 battery 4 lagay hain masjid me kam sahi nhi chal raha please reply help karen Allah apka bala karen aameen reply must sir
Thanks
03006715530
WhatsApp Messgage only
sir mary pas osaka taltublar 1800 bettery hy abi bs 7 month hoy hy 400 waat k load pr just 30 min backup dy rhi hy phaly ups us ko 25 ampire pr 3 ganty charge krta tha ab just 15 minute charge krny ky bad bettery full ka option dy kr charge krna band kr data hy mai ny simtak ka new charger lyea but wo charger b 30 min charge krny ky bad bettery full ka option dy kr charging stop kr data hy bettery charge ni ho pa rhi tbi backup ni mil rha mai ab kya kro pzz help
Brother same issue with Hawk tubular battery
Battery 1hr mein charge ho jaati hai
@@umairkazmi733 bhai mara problem solve ho gya hy mai ny sari rat tanger pr lgwai thi battery ab 22 ampire py 3 ganty tk charge hoti hy wrna phaly 15 min charge ho kr band ho jati thi charging ap b tanger pr lgwaoo ake rat
اسلام علیکم سر کیا حال ہے سر میرے پاس ہومیج کمپنی ماڈل1212SCC ایک کلو واٹ کا انورٹر MPPTچارج کنٹرولر ہے اس کے ساتھ بیٹری کون سی بہتر رہے گی شکریہ
HOD1212SCC ماڈل ہومیج کمپنی ایک کلو واٹ کے لیے کون سی بیٹری بہتر رہے گی شکریہ جناب
Sinko MPPT charge controller k Sath tubeler batry use ker sekte Hein
کیا فیصل نان ھائبرڈ 65ایمپئر پر لیتھیئم بیٹری چارج کر سکتے ہیں
aoa bhai 4mm wire and 6mm wire par video banaen 10 panels serires main 14amp max k liay konsi wire use karain gay thoury kahti hai 4mm 25 to 30 amp k liay kafi hai please video banaen
Ok
Ap achy results K liay 8mm use kren
Simple rule hai jo rheory kahti hay usko 50% pe le kar practically use karo
For example agar aik cable 50A tak carry kar sakta hai to ap usko 25A se zyada ke liye use na karein
کیا ہم inverex veron 2.5 kw کے ساتھ ٹال ٹیوبلر بیٹری استمعال کرسکتے ہیں۔ ؟؟؟ براے محربانی رہنمائ فرمائیں❤️❤️❤️
12V best tubular knsi e 4KW solar system k lie
سر میں نےMaxpower pv7000pro
لگوایاہے ساتھPhonix tublar 2500
لگوائ ہیں jinko 555 14plate
کےساتھ لیکن رات کو بیٹری کا بیک اپ 5پنکھے اور ایک فریج کے ساتھ صرف 2گھنٹے ارہا ہے
Mai ne sako inverter lagaya hai 3.5 aur ab ye tubular 2500 phoenix charge nahi karti
Tubular battery 🔋 galti sr bi na lena, tx 1800, 185 ah li thi ghatia aj tak charge nai huwi pese bekar na lena,,, normal osaka lelo without tubular .. wo best ha,, hamara inverter inverex xtron 1200 ha 1kw ka.....
AoA
Inverex Aerox 3.2
Rison 330 wants 8 panels
Osaka 1800 tr 2 batteries
Batteries parameters Settings kia honi chahye please guide
سر 580 واٹ جنکو N ٹائپ کے 2 سولر پینل ہیں، 3 پنکھوں خورشید ڈی سی فین اور 2 لائٹس ہیں، اس کےلئے فورس کمپنی کا ایم پی پی ٹی لینے کا ارادہ ہے، اب بتائیں کہ اس کےلئے کونسی بیٹری لوں ٹیوبلر یا سادہ؟
Simple lgayn...mne Osaka 2500 lgai hy wo fail hy
@@zsfakhar1904
سر جو لوڈ اوپر بتا چکا ہوں اس کےلئے Exide hp 200 ماڈل جسکا ایمپیر ہاور 130 ہے ٹھیک رہی گی یا اس سے بڑی،
اگر پوری رات کےلئے بیک اپ لینا ہو۔ کیونکہ میں بجلی پر انحصار ختم کرنا چاہتا ہوں۔
Sinko ya sintek lo mppt
Phonix 1800 wali laga lo me khud use krrha hun 56k ki milegi
Tubular
@@BilalKhan-de3wg tubular
Yah baat sahi ha ma na 2 year phalay tublar battery lagahi 1 year ma khatam phir ags tublar battery lagahi woh bhi 1 year bass in dono ka backup nahi ha sahi ma kahan ga normal battery lan
سلام۔ میرا 450 واٹ کے دو سولر پینل کا ڈی سی سسٹم ہے۔ ٹوٹل 900 واٹ۔ 60amp کا simtek کا mppt چاجر ہے۔ کیا یہ چارجر ان سولر پلیٹ کے ساتھ TX 1800 کی ٹال ٹیوبلر بیٹری کو چارج کرے گا؟
G charge kr ly Ga lkn agr 80A ka hota to zyada acha hota
Inverex 2.5kw inverter k sath 2tubular battery attach krna chahta hu backup kitnay ghanty ka ho ga 2fans or LED tv+ 3or4 led lights ka rehnmai fermay
جناب اکثر گھروں میں ups لگا ہے اور انورٹر انورٹر کی باتیں کر رہے ہیں ہم خود لوکل ups اور 2 بڑی پلیٹس پہ یہی ٹیوبلر بیٹری استعمال کر رہے ہیں کیونکہ ups میں bulk چارجنگ کی option نہیں ہوتی سارا دن تو گزارا چل جاتا ہے لیکن شام کو یہ بیٹری فل ہونے کے باوجود 2 یا اڑھائی گھنٹے سے زیادہ 300 واٹ کے لوڈ پہ بیک اپ نہیں دیتی، بہت بے کار بیٹری ہے 56 ہزار روپے ضائع ہوگئے بہت افسوس ہوا
My tubular battery overflowing water why
Overcharging occurs!
Assalamoalikum bahi mery paas 550 w k 2 panels hai or 60 amp k force Mppt hai DC load run karna hai.DC load 3fans and 1 invertor freezer hai .mei tx 1800 tubeler battery lagasakta hun.please reply
Battry calculaion chk krn
@@SubEngineerOnline Mary sawal ka jawab Nahi Mila sir
لگا سکتے ہیں
Fail hgii
لیتھیم بیٹری جب پانچ سال لائف ختم کرنے کے کتنے میں فروخت ھو گی ؟کیا لیڈ ایسڈ استعمال بک سکتی ھے
اسلام علیکم بھائی آپ ٹیوبلر بیٹری کی گریوٹی کے بارے میں جتنی بھی ویڈیوز بنا رہے ہیں میں نے آپ کی ساری ویڈیوز دیکھی ہیں مجھے سمجھ نہیں آ رہی کہ ٹیوبلر بیٹری کے amp اور bulk volt اور flot volt کتنے رکھنے چاہیے
جیسا کہ میرے پاس crown کا 3.6 Xavier IIکا انورٹر ہے اور PHONEX کی TX3500 280amp کی دو بیٹری لگی ہیں یعنی 24 وولٹ سسٹم ہے
مسئلہ یہ ہے کہ بیٹریوں کی گریوٹی 11.50 سے اوپر نہیں جاتی
31.5 وولٹ پر90 منٹ equalization کرنے سے گریوٹی تو پوری ہو جاتی ہے لیکن اگلے دن پھر 11.50 پر آ جاتی ہے
بیٹری چارجنگ amp 30
Bulk volt 29.2
Flot volt 27.0
رکھے ہوئے ہیں سسٹم کو لگائے ہوئے 1 ماہ ہوا ہے
Battery discharge 20 amp
سے زیادہ نہیں ہوتی کیونکہ ہمارا لوڈ ہی 20 apm تک ہے
دن کو بھی لوڈ زیادہ نہیں ہوتا ضرورت سے زیادہ بڑا سسٹم لگا ہے 545 کے 8 پینل لگے ہیں جو ضرورت سے زیادہ ہیں
مسئلہ گریوٹی نہ پوری ہونے کا ہے
حل بتائیں؟
ظاہر سی بات ہے کہ ہر روز تو بیٹری کو equalize تو نہیں کیا جاسکتا؟
نوٹ :
بیٹری کی وائر زیادہ لمبی بھی نہیں ہے اور 25mm لگی ہوئی ہے
تمام parameter پورے ہیں
ہم واپڈا کو مکمل بند رکھنا چاہتے ہیں
Almost same problem, backup bilkul nahi milta, aaj kal sunlight b pora hai but phir b gravity sahi se pore nahi hote
میرے گھر میں 3KW کا سولر سسٹم لگا ہوا ہے۔ اس کے ساتھ اوساکا کمپنی کی 185 ایمپئیر والی دو بیٹریز لگی ہوئی ہے۔ میری بیٹری کے ساتھ بھی یہی مسلہ ہے، میں بھی جب بیٹری سے بیک اپ لیتا ہوں تو اگلے دن چارجنگ کے باوجود بیٹری کی گریویٹی لو رہتی ہے اگر میں بیٹری سے بیک اپ نہ لوں تو ایک دو دن میں بیٹری کی گریویٹی خود ہی پوری ہو جاتی ہے۔ حالانکہ میں نے کبھی بھی بیٹری کو فول ڈسچارج نہیں کیا نہ ہی اس پر بہت زیادہ لوڈ ہوتا ہے زیادہ سے زیادہ لوڈ 20 ایمپئیر تک ہوتا ہے۔بلک اور فلوٹنگ وولٹیج زیادہ کرکے بھی دیکھے ہیں لیکن کوئی فرق نہیں پڑا۔ بلک وولٹیج 2۔29 اعشاریہ دو ہیں فلوٹنگ وولٹیج 8۔28 پر سیٹ ہیں۔ اگر ہم بیٹری سے بیک اپ نہیں لے سکتے تو ایسی مہنگی بیٹریز خریدنے کا کیا فائدہ۔ اگر کسی بھائی کے پاس اس مسئلے کا حل ہے تو مجھے گائیڈ کریں۔
Yes bhaai.. i have solution...
Jb apki battery low hoti ha to ap disconnect kr do inverter se.. means battery ka breaker off kr do..
Bhai 48V system me inverter ke cut off 42v ha... Laikin jub b discharge kertay hain to 1 battery 9 volt tak b chali jati ha... Aisa kiun hota ha jab k supply cut off b nhi hoti
Bhaai wo is liye hota ha , agr ap ne cut off 42v rkha ha , inverter us se backup power lena chor deta ha, lekin wapda pe shift ho ke bhi inverter battery se power leta hai. Means inverter on rehta ha wo 50watt battery se leta rehta hai, is trah se battery apki dead hojati hai
@@MrAnwar44555 wapda b nhi the us wakt.. tab hi to batteries se backup chal rha tha
Datou Boss 2000W Pure Sine Wave Tubular k sath lgaya ja skta hy ???
Car Inverter hy
Europeon Standard wala
.
Battery ka talaq MPPT ki charging sy hy ya
Inverter sy hota hy ?????