Sir I want to install submersible pump at depth of 80feet n height of 70 feet, total head 150 feet approx in Delhi. Water to fill is 6000 lts per day. Pls suggest if I should go for 1hp with 12 stage or 1.5hp with less than 10 stage V4 as it is said if I install 1.5hp n it is being used below average then it will start giving problems, as told by few shopkeepers. And does water submersible are eazy to repair n does not give problem as it has water inside? And lastly which is better KSB or CRI ? And which cable to use, 1.5 or 2.5mm 3 core for 1hp & 1.5hp ?? Regards
Bore wale ne 2 se 2.5 inch pani bataya h. 450 feet boring h. Plant me use krna h continue kitna der tk chala sakte h ? Kitna Hp aur kitne Stage ka submersible kharidna hoga ? Submersible me kitne weight ka pipe lagega ? 2" ka pipe laga sakte h kya
Sir, hamara borewell 800 feet hai water level 550 feet hai to 600 feet pe chalane ke liye kitne hp ka pump or stage lagega .pipe ki size 3 inch hai. Please reply sir 🙏
sir 120 feet deep 6 inch casing 10 ki stage h,sir parashn ye h submersible pump kitne hp ka lagana chahiye(zaroori)h plzzzz replay sir... replay kaintezar rahega sir plzzz👍
Bhaiya meri borvell ki gahrai 220 hai aur pani nikalna star huaa hai 80 feet se aur mai 100 feet hi dalna chah raha hu pipe to mujhe kitne stage ki machhin dalan chahiye pls reply me
Sar mere yaha borwell 80 feet me nikla or 130 feet total drill karaye par motor 1.5 HP, 10 stage wala dale hai par Pani 1 minat fek rha hai fir ruk raha fir 10 minat bad fir 10 second chal rha hai kya problam hai or white upvc colom pipe kitna feet dalna chahiye.....9 pipe me 7 pipe andar motor sath dale hai....8 pipe niche tike taype laga kya kare...sar plz reply 🙏🏼🙏🏼🙏🏼🙏🏼🤔😥
सर मैंने अपने घर में 1hp 18 stage की सबमर्सिबल पंप लगाया है, 250 feet गहरा और पैनल में 120 mfd स्टार्टर एवं 50 mfd रनर कैपिसिटर लगा हुआ था तब 200 volt से अधिक होने पर ही मोटर से पानी आता लेकिन 200 volt से कम होने पर मोटर चालू तो हो जाता पर पानी नहीं आता, अपने घर में वोल्टेज 130 से 190 तक ही वोल्टेज होती है, केवल कुछ समय ही 200 volt आती है। एक इलेक्ट्रिशियन भाई एक और runner capacitor 50 mfd का लगा दिया, अब 50-50 के दो runner capacitor लगा है जिससे 150 volt से ज्यादा होने पर पानी आ जाता है। मेरा प्रश्न है कि 50-50 के दो runner capacitor लगा होने से submersible pump को नुकसान तो नहीं होगा न। कृपया रिप्लाई जरूर करें। 🙏🙏
4"बोर है..4v सब मार्सिबल पंप अटकता है तो 3-v सब मार्सिबल पंप लगाते है..और बोर 60 फीट है और पहले मजले पर टैंक है करीब 100 fit hota है..तो किर्लोस्कर टेक्समो याह CRI का पंप मिल जाएगा..प्लीज जवाब देना.....?
Main nahin boring karana chahta hun aur usmein nai motor dalna chahta hun Bhai aap kahan se ho aap se Milana chahta hun jisse jankari acchi tarah se mil sake
Bhai hamare yahan sirf 80 fit borwell hua h .... Fir pani ki vajah se aage drill ni kr sake to.. Hum 1 hp ka pump laga rhe hai to ...kitna niche utarna chahiye hume plzzz replyyy me...
bhot hi sahi aur acha video tha sir
isi tarah sahi batate rho sir..
thank u,helpfull video👍
bahut badiya samjhaye sar pura samajh aa gaya stage ke bare me 😀😀😀🙏🏼🙏🏼👍👍
Very good sir ji esi tarah submersible pump repair ka video banate raho.🙏🙏🙏🙏🙏🙏
Sir
I want to install submersible pump at depth of 80feet n height of 70 feet, total head 150 feet approx in Delhi. Water to fill is 6000 lts per day.
Pls suggest if I should go for 1hp with 12 stage or 1.5hp with less than 10 stage V4 as it is said if I install 1.5hp n it is being used below average then it will start giving problems, as told by few shopkeepers. And does water submersible are eazy to repair n does not give problem as it has water inside?
And lastly which is better KSB or CRI ?
And which cable to use, 1.5 or 2.5mm 3 core for 1hp & 1.5hp ??
Regards
Thanks❤ bhai g
Vedio atcha laga.
Sir hamara borewell 450 feet hai water level 300 hai jk callisick 2hp 7 stage mai kitna voltage hona chahiye
Minimum kitne hp ki ati hai sir ...mera ghar ki bor 70 fit par hai kitna sahi rahega
Bore wale ne 2 se 2.5 inch pani bataya h. 450 feet boring h. Plant me use krna h continue kitna der tk chala sakte h ? Kitna Hp aur kitne Stage ka submersible kharidna hoga ? Submersible me kitne weight ka pipe lagega ? 2" ka pipe laga sakte h kya
Sir. 245. Feet par 2/15 ka pump chalega kya ?
Nice video sirji 👑🙏
Bhai g 5 inchi bor hai or 100 feet Tak pipe hai
60 feet per moter dalni hai
Kon se stage ka pump or moter Dali v4 ya v5
12.5 hp me kitne stage ka pump dalna chahiye 200-300 ft. Gahre pani ke liye
Sir, hamara borewell 800 feet hai water level 550 feet hai to 600 feet pe chalane ke liye kitne hp ka pump or stage lagega .pipe ki size 3 inch hai. Please reply sir 🙏
Sir bore siz 5 inch gahrai 65 feet h konsa pump lena chahiye
Thank sir 🙏
3 inch water ,50 feet bor me konsa pump lgana chahiye
Sir bire size 8 inch and gahrai 150 feet h konsa pump lena chaiye bhai ...
Nice video
Sir 3 ho motar ke pankhe min yadi 3 empelar kam ho jayenge toh kya hoga kripya batayen pehle 19 the ab 16 lagaye
sir 120 feet deep 6 inch casing 10 ki stage h,sir parashn ye h submersible pump kitne hp ka lagana chahiye(zaroori)h plzzzz replay sir...
replay kaintezar rahega sir plzzz👍
Maza aa gaya
Bhaiya meri borvell ki gahrai 220 hai aur pani nikalna star huaa hai 80 feet se aur mai 100 feet hi dalna chah raha hu pipe to mujhe kitne stage ki machhin dalan chahiye pls reply me
15 steg 1.5hp or motai (size) 2.5"inch ki samarsebal mij ayegi kya or mil jayegi to phir kitne ki padegi jarur batana bhai please reply
बहुत अच्छी जानकारी दी भाई आपने
Sar mere yaha borwell 80 feet me nikla or 130 feet total drill karaye par motor 1.5 HP, 10 stage wala dale hai par Pani 1 minat fek rha hai fir ruk raha fir 10 minat bad fir 10 second chal rha hai kya problam hai or white upvc colom pipe kitna feet dalna chahiye.....9 pipe me 7 pipe andar motor sath dale hai....8 pipe niche tike taype laga kya kare...sar plz reply 🙏🏼🙏🏼🙏🏼🙏🏼🤔😥
Bhai 3 inchi pani ke liye kita hp ka samarsebil dale 95 fit gehra bor bil he or samr se bil ki kimat kya hogi jannetar se chalani he
Thanks sir ,How to double submersible wire
Moter ulthi chalai to jamiga kiya sir samarsibal burwell me 3.15 v4
Nhi
115 feet boring h aur pipe 100 feet pe motor daalna h to 10 stage .5 half hp lga skte h
Mai borewell kraya hu mujhe summersibel motors lena hai to kon sa lu ky lu details me bataye
Good नॉलेज
Sir maine 400 ft bor khoda h.aur mujhe motor kitne h.p aur kitne stage ki lagegi
50 fit se Pani nikalne ke liye ketne stege lagte hai
Electric meter alag lagata hain????
2500 fit hits pe panii pauchawne ke lily Kitna stage Ka motar Lene hoga
Sir muje texmo 3hp pump se 160 feet se Pani निकालने he 2.5 inch
22 स्टेज के सबमर्सिबल पम्प को 15 स्टेज बनाया जा सकता है क्या?
K7 impeller
Yes
1200 fit pa kitna staj kaa pump laga gaa 20 hp ki motar ha
Sir home samarsibal h 1inch panih h 35 fit ghara bor h 18 fit par pani ka leval h or 1hp ki motar h to motar ko 4 inci bor me kitne fit tak utare
चार नंबर का एंपलॉयर कितना फिट का पानी देता है और सात नंबर का एंपलॉयर कितने फिट का पानी देता है यह बताइए
Sar 250 fit ka pani nikalna he to kite sep ka lagega
Nice 👌
Good
सर मैंने अपने घर में 1hp 18 stage की सबमर्सिबल पंप लगाया है, 250 feet गहरा और पैनल में 120 mfd स्टार्टर एवं 50 mfd रनर कैपिसिटर लगा हुआ था तब 200 volt से अधिक होने पर ही मोटर से पानी आता लेकिन 200 volt से कम होने पर मोटर चालू तो हो जाता पर पानी नहीं आता, अपने घर में वोल्टेज 130 से 190 तक ही वोल्टेज होती है, केवल कुछ समय ही 200 volt आती है। एक इलेक्ट्रिशियन भाई एक और runner capacitor 50 mfd का लगा दिया, अब 50-50 के दो runner capacitor लगा है जिससे 150 volt से ज्यादा होने पर पानी आ जाता है।
मेरा प्रश्न है कि 50-50 के दो runner capacitor लगा होने से submersible pump को नुकसान तो नहीं होगा न। कृपया रिप्लाई जरूर करें। 🙏🙏
Ho sakta Bhai nuksan.............phar aapka voltage kam hai na
Koi problem nhi
Jyada voltage pe mat chalu karna
@@antictechnologyplus6237 ok sir
Single fiz 250 feet 1.5 inch ka paip kitni hp ki motor lena hogi or voltage kitna chahi ye bataye sir 🙏🙏🙏
4"बोर है..4v सब मार्सिबल पंप अटकता है तो 3-v सब मार्सिबल पंप लगाते है..और बोर 60 फीट है और पहले मजले पर टैंक है करीब 100 fit hota है..तो किर्लोस्कर टेक्समो याह CRI का पंप मिल जाएगा..प्लीज जवाब देना.....?
Bhai mera pumps 8 stage ka h or 10 hp ki motor h porani par wo 12 nojjel chalat h kal ki repair kar wa ke lye h 120 feet par dali h noojel kese badhya
10 stage 4hp ka pump 200 fit me laga sakte hai kya khet ke liye 3fac
Supar.sar🙏
Kiya bhai 3hp pr 1hp wala pump lga skte h kiya
190 fit 3 inch pipe he 20HP ka Motar he kitna steg ka pump Laghe a
750 feet ke liya kon sa pumpe lga na padega
Sir 1hp motor 15stage nahi chal sakti itna amp nahi chal skte motor lod lee kge oske smratha nahi hai 15stge 1.5 ho pe lage gA
Kya stage jada hoga to pani jada nikale ga
सर जी मुझे 550फीट से पानी निकाल ना है 10
एच पी की मोटर थी् फेज में कितने स्टेज का पंखा लगाना पड़ेगा
Main nahin boring karana chahta hun aur usmein nai motor dalna chahta hun Bhai aap kahan se ho aap se Milana chahta hun jisse jankari acchi tarah se mil sake
Mre pas c.r.i .ka pmp hy 17 tej 430fit she Pani ka fors kiu nhi ata sar
मेरा बोर 8 इंच का है 600 फीट उसमें 450 फीट मोटर उतरना है उसमें कितने एचपी काम मोटर पंप उतारे
400 feet bore hai kitni stage ki motor lagwana chahiye
Hello sir mujhe 650 feet par submersible pump laga na hai agriculture ke liye please batae
225 feet bore me texmo ka kitne stage ka pump lgega or kitne feet pr lagega pani 1.5 inch h
2 hp 15 st
Sirji mere ghar me 210 feet borewell he,150 feet par 0.75 se 1 inch pani laga to kitani hp aur stage ka jet pump lena padega
15
@@antictechnologyplus6237 kitani hp ki motor leni hogi
👍👍✅
Sir joint banate samay kaala simple tep use kar sakte hai
Nhi
Kya aap bata sakte ha ki v4 Ka kora 2 ya kora 5 kitne wat Lete he
400 feet me kon sa moter laganga hai kitne stage wala
सर जी 5hp पांडडुबी मोटर 10 amp लेती हे
अगर कुएं के आनद पानी में उस मोटर का रोटर जाम हे तो ये मोटर कितना amp लेगी
Muje 500 feet hight me pani le jana h kon si moter tik rhegi PLZZ helf me
Y hmare pass 5 hp 3 stage pump hai. Kya hum 4 stage pump lga sakte hai ???
3 stage 😂
Bhai hamare yahan sirf 80 fit borwell hua h .... Fir pani ki vajah se aage drill ni kr sake to.. Hum 1 hp ka pump laga rhe hai to ...kitna niche utarna chahiye hume plzzz replyyy me...
50-60
Sir hame jaise 3hp ka motor aur 10 stage use kare to thik rahega 80 fit ke liye
Ha
Yah bataiye 6 stage ka motor kitne fit se Pani nikal sakta hai
2hp 40 stage v4 dal sakte he kya
125 feet ke liye kitna stage ka hoga
150 fut tak lagana he or oil fild sabar ka kese rahega singal fec 1 hp
1 hp me kitnastej vala pamp jyada pres deja
ईपिलर नंबर 2 ,4,5,7,10 ऐ सारे 15 फिट पाणी उपर लेते है का सर
Haaaaa......
120 fit 2 HP kitna stage Singal fass me pani full ana chahiye
70 feet par kaun si Company ki motor dale 6inch bore hai jet pump ke liye kitane Horse power motor chayeye
400ft me 2.5 inch full presar ke liye Kitni HP ki motar or pump lagaye
35 stage or
1.5hp
Hello sir pump alag as mil jayga kya 25 stage ke kya price hoge
Hello sir 1.5 hp me 6-8 stege ka panmp cal sakta hai ki nahi
Ha
5hp 3ph motor 2 inch delivery kitne feet par chal sakti he
Bhai mene single phase par 450 fit pe 2 hp 20 stage lagaya hai problem ho rahi hai kabhi pani ata hai kabi nahi kya karu please bataye 🙏
2*20 350 fit tk hi chalega
@@antictechnologyplus6237 kitna dalna hai bataye 🙏 please
Ket me chalana he sire riply de
700 feet ki gaharari me kya dale
मेरा 3 एचपी का मोटर है और उसका वोल्टेज नहीं पड़ता है तो क्या किया जाए
15 state ki motor 60 feat mein dalne se Pani kaise milega
150 se 180 fit m ktna hp ka motor or ktne stage ka motor lagana chaheye
1hp 10 stage , texmo me
Mujhe 1.5 hp motor chahiye kam budget m konsi lu jo long time tak chal jaye.
Or kaha se buy karni h link bhi send kar dena.
6353366762
Sir mein aapki workshop visit Karna chahta hoon please edress Batane ki kripa Karen thankyou
Sar agar koi pump kahan per kharidna chahe bhi kaise khareed sakte hain
10 hp की मोटर है और 600 फीट pr पानी है तो कितने स्टेज का पंप लगाए
पंप किती अंतरावर ठेवावा म्हणजे पाणी प्रेशर योग्य मिळेल
अगर under ground me 80 feet+उपर tank 85 feet ho aur pipe line me 2जगह bend lagaye ho to Kitna hp aur Kitna stage Ka pump le
10 stage ka pump kitne feet mai lagaye
मेरे पास 5 एचपी सिंगल फेस 6 इंच की मोटर हे होल की गहराई 235 फिट कितने स्टेज का पम्प लगाए जो पानी ज्यादा से ज्यादा बाहर निकाले
मेरे को भी लगाना है यही जवाप दो जी please
900 fit mai kone sa pamp lagna chahiye
Summersible pump का spare कहाँ मिलेगा?
Aapko kya chahie bhai bolo