Navien NFC-175 Combi-Boiler Retrofit #4

Поделиться
HTML-код
  • Опубликовано: 3 янв 2025

Комментарии • 51

  • @dekonfrost7
    @dekonfrost7 Год назад +4

    Honestly the best
    On youtube. Fact. .

  • @andriisuvorov2793
    @andriisuvorov2793 Год назад +1

    One of the cleanest jobs I ever seen!

  • @Ezzy1992
    @Ezzy1992 Месяц назад +1

    Wow ball valve on the expansion tank yes 👏🏽, ball valve on the air bleeder on top bravo 👏🏽 Jesus I haven’t seen anything like this 👏🏽👏🏽👏🏽👏🏽👏🏽👏🏽

  • @ephatla58
    @ephatla58 2 года назад +1

    I've learned more in 20 minutes watching your video than in the last 2 days trying to find system layout instructions. Thank you.

  • @akrocuba
    @akrocuba 2 года назад +3

    Sir, I agree with the lowest price that people take. They will either pay now....OR....pay later.
    I've been a plumber/pipefitter/boiler service tech, ect since starting doing work when I was in high school in 1983.
    I can say you have done a job WAAYYYY above and beyond!!! IT IS BEAUTIFUL!!!!! NOT ONLY BEAUTIFUL, BUT FUCTIONAL AS YOU DESCIBED IN THIOS VID!!!!
    WOW!!!! I don't see many younger guys taking prided in their work anymore. It's always seems to be just get in and get it done.
    Your are worth your weight inn gold!
    MUCH RESPECT!!!!

  • @jeffreybricks2687
    @jeffreybricks2687 Год назад

    Not only you are veryyyy very successful at boiler Installs and clean instal excellent!!! But good also at teaching THANKYOU!!😀

  • @donmccormick856
    @donmccormick856 Год назад +1

    Your work is second to none....would have liked to see how you vented it at the roof have never seen one vented that way.

  • @ChuckKarl525
    @ChuckKarl525 2 года назад +1

    You are proud of your work and you should be. There are many out there like you, and I wish the news media would focus on the good in humans rather than....well, lets focus on boiler installs! Be well.

  • @TheZambie1
    @TheZambie1 2 года назад +1

    Great videos, very helpful! Adrien from Upstate NY

  • @tonykim901
    @tonykim901 Год назад +1

    Very clean. You work New Jersey. I’ll hire you. Great, beautiful and clean. I always say clean means you care.

    • @Ezzy1992
      @Ezzy1992 Месяц назад

      I think he is in Canada 🇨🇦

  • @tylero8595
    @tylero8595 Год назад +1

    On your thermometers for your delta t, have you thought of using tri-dicators? We use them. Pressure and temp in one. They're very easy to read too. You're boss level work as always.

  • @jeff-w
    @jeff-w Год назад +2

    First time I've seen old pro-press fittings and as expected they're leaking. I don't understand why some people think they're the cats ass these days...its an elostomer seal! Elastomers always fail in time.

    • @GoldPlumbing
      @GoldPlumbing 3 месяца назад

      Job security.. 😢 win for the tradesman, loss for the customer.

  • @ramijaime2213
    @ramijaime2213 Месяц назад

    Good woork brother

  • @MrRickyt88
    @MrRickyt88 2 года назад +1

    Thanks for the video that’s a masterpiece. Why should we not use propress on heating systems?

  • @longrangecarpenter5292
    @longrangecarpenter5292 2 года назад +1

    Where did you get the isolation valves for the pump with the 1/8” not ports for the temp gauges ? I’ve searched everywhere ….

  • @christopherwilson2606
    @christopherwilson2606 2 года назад

    Here in the south we call em, "get the airs out-of-theres." 👍

  • @Johanfriesen
    @Johanfriesen 2 года назад

    Thank you great video, I’m near London On, will start building our new home in Nov. where can I get a quote and can I have 10 zones for heating?

  • @petem6291
    @petem6291 2 года назад

    James each time you do one of these boilers you raise the bar on the quality of the installation I’m getting ready to install a fire tube boiler . In my own house I have to install a low-water cut off where would you install it on a fire tube boiler .

    • @canuckmechanical6490
      @canuckmechanical6490  2 года назад +1

      close to the boiler in the case of the Navien they have an outlet on the top for such a device but regardless its should be placed above the boiler and above all pumps return or supply side does not matter

  • @lesleyboeder1798
    @lesleyboeder1798 2 года назад

    Very nice. Love the way you plan these systems. I just would rather see you use Bosch instead of Navien

    • @canuckmechanical6490
      @canuckmechanical6490  2 года назад

      Not common enough in This region yet

    • @xcmskim4
      @xcmskim4 2 года назад

      I see you've been watching Mikey Pipes? The fire tube models don't have the horrendous leaking heat exchanger design

  • @dandan6018
    @dandan6018 Год назад

    where is the Prv on the water main there?

  • @longrangecarpenter5292
    @longrangecarpenter5292 2 года назад

    What grundfos model hot water recirculation pump would you recomend for one of these combi boilers ?

  • @markhoffman
    @markhoffman 2 года назад

    Any benefit insulating all those copper pipes?

  • @ephatla58
    @ephatla58 2 года назад

    Would you be able to do a parts list in the description?

  • @leonginorivera8309
    @leonginorivera8309 10 месяцев назад

    What's the reason to install that zone control. Can you would run the circulator pump with a relay box. Just question?

  • @Jessedog11
    @Jessedog11 Год назад

    why would you need a auto vent on the expansion tank bracket/manifold? and that Bypass you set up on the neutralizer condensate drain will never be seen and untreated acidic water will simply destroy the condensate pump.

  • @andyyu3627
    @andyyu3627 2 года назад +1

    Do you have a contractor in the San Francisco area?

    • @canuckmechanical6490
      @canuckmechanical6490  2 года назад

      Unfortunately no:( but we are starting a hydroponics branch in Birmingham England next year but sadly no help there

  • @BurtGummer357
    @BurtGummer357 2 года назад

    Great job where did you get those black pipe supports for the 3/4” copper pipes

    • @canuckmechanical6490
      @canuckmechanical6490  2 года назад

      There are called pipe stays and they are at all our suppliers

    • @BurtGummer357
      @BurtGummer357 2 года назад +1

      @@canuckmechanical6490 thanks so much for that info I will look into those here in Colorado keep up the great work you guys do hard to find that anymore a company and there people that take pride in there work!!

  • @joker-if4gu
    @joker-if4gu Год назад

    How much would you charge for a job like this?

  • @Fernando-ns3uv
    @Fernando-ns3uv 2 года назад +1

    Who makes those black pipe clamps?

  • @samihabib661
    @samihabib661 2 года назад

    Amazing install, I would have used PEX A instead of PEX B

  • @omarjavierq
    @omarjavierq 2 года назад

    How do you balance the flow in each zone?

  • @markhoffman
    @markhoffman 2 года назад

    Spray paint the pump wire. ❤

  • @miketransamkid
    @miketransamkid 2 года назад +1

    Wanna come to the states and redo my setup?

  • @TheLogneo
    @TheLogneo 2 года назад

    Look like Navian have a big issue with heat exchanger, and motherboard

    • @xcmskim4
      @xcmskim4 2 года назад +2

      Fire tube models don't have the horrendous leaking heat exchanger design found in Mikey Pipes videos