Allowable Ampacities of Insulated Conductors

Поделиться
HTML-код
  • Опубликовано: 16 окт 2024
  • Sa video na ito ituturo ko sa inyo ang PEC Table 3.10.2.6(B)(16)
    Allowable Ampacities of Insulated Conductors Rated Up to and Including 2000 Volts, 60°C Through 90°C, Not More Than Three Current-Carrying Conductors in Raceway, Cable, or Earth(Directly Buried), Based on Ambient Temperature of 30°C as per PEC
    Welcome to Jun Aux TV if you enjoy watching this video don't forget to subscribe, like and hit notification bell thank you!
    Also visit my FB pages and group:
    JB Handyman Services
    ✓If you’re looking for the right person to fix the problem your facing in your home you can find it here, License Electrical Practitioner is available here, visit us
    Jun Aux TV
    ✓all about Electrical installation and Electrical devices reviews and safety awareness on Electrical
    JB Online Shop
    ✓you can buy product such as Electrical devices mostly on industrial devices
    www.facebook.c...
    Electrician For Hire
    ✓group of Electrician looking for a job and giving and taking ideas in one another
    JBLyricsVideo
    ✓its all about lyric video on popular music now a days
    Thanks for Watching hope you enjoy. God bless

Комментарии • 269

  • @lorets10
    @lorets10 3 года назад +1

    Master jun para poh mas maintindihan nila lalo mag example ka poh ng real wire para malaman nila ung pinapaliwanag mo.. pag wala pong actual na example ng wire nakakalito hehe salamat master jun..

  • @noelraras379
    @noelraras379 4 года назад +1

    Salamat sir....natuto aq sa turo dito at sa ibang vodeos mo....hndi po aq electrician...pro nag i install aq dito bhay thru wido

    • @junauxtv
      @junauxtv  4 года назад

      Sir mag iingat ko kayo sir if alanganin po kayo mas magada ipagawa aa marunonh

  • @fernantrain8644
    @fernantrain8644 4 года назад +2

    Sir galing nyo naiintindihan ko yung turo nyo. The best very clear. Keep up the good tuturial

    • @junauxtv
      @junauxtv  4 года назад

      Maraming salamat po sir...

  • @edamansec9565
    @edamansec9565 4 года назад +1

    Hindi ako electrician, nag DIY lang ako. Thank you very much marami akong natutunan. At macorrect yong mga mali kong ginawa.

    • @junauxtv
      @junauxtv  4 года назад

      Maraming salamat din po sir....yan po talaga purpose ng channel natin sir

  • @sherrylperlas8729
    @sherrylperlas8729 5 лет назад +1

    sir...my natutunan nanaman ako....matagal kona hinhnttay to..marami salamat...good job...mas maliwanag pa sa araw...tnx sir jun...

    • @junauxtv
      @junauxtv  5 лет назад

      Salamat din po mam...

  • @opecons
    @opecons 3 года назад +2

    Boss absolute ba na hindi pwede lalampas sa 3 wire sa isang conduit? Paano yung table sa pec na may maximum number sa isang conduit?

  • @viajebyahelang4043
    @viajebyahelang4043 4 года назад

    Nice tutorial PEC standard

  • @torcrame4183
    @torcrame4183 5 лет назад +2

    Fair enough master Jun....ok yan atleast may idea sila about different type of wire insulation according to temperature and ampacity.👍

    • @junauxtv
      @junauxtv  5 лет назад

      Oo nga sir... dagdag kaalaman din yan sir

  • @michaelabrenica3259
    @michaelabrenica3259 2 года назад

    sir ask ko lang kasi nag diy lang ako. ano klaseng wire dapat gamitin mula sa scc to battery at battery to ac load? battery cable ba o pwede yung thhn?
    salamat po

  • @era1308
    @era1308 5 лет назад +1

    nice montik ko na to malimotan..buti nlng.

  • @emmanuelbandagosa2048
    @emmanuelbandagosa2048 2 года назад

    Ano ba ginagamit na brand ng wire ang karaniwang ginagamit sa service entrance??

  • @reymunddomingo9611
    @reymunddomingo9611 2 года назад

    Gud pm. Sir. Question ano naman po number ng wire at circuit breaker gagamitin sa 3/4 ac window type. Tanx. Po.

  • @crisremata4708
    @crisremata4708 2 года назад

    Ang tawag mm² ay "Metric System", ang awg naman is "English System", yun ang pagkakaalam ko. At tama nga yung sinasabi ni kuya Jun, metric system ang palaging ginagamit sa mga plano.

  • @tecnilojumarito8729
    @tecnilojumarito8729 3 года назад

    Salamat Master add more knowlege sa akin po!!!!!

  • @rolandocadawas9705
    @rolandocadawas9705 4 года назад

    Sa mga farm housing o agricultural structures ano ba ang pwedeng gamiting wire conductor

  • @pitz10
    @pitz10 4 года назад

    safety factors then ba ito na table. kasi mas malaki pa sia sa pinapractice natin na ampacity sa totoong specs ng wire?

  • @larongklasiko7731
    @larongklasiko7731 2 года назад

    Sir kung #14 o 2.0mm thhn ang gagamitin ko sa 15amps na breaker wala po bang problema yun?

  • @roldanmasendo6022
    @roldanmasendo6022 4 года назад

    Para to sa stranded wire sir.same lang ba kong gagamit ako ng royal cord na wire same parin ang capacity ng wire

  • @glennv9019
    @glennv9019 5 лет назад +2

    salamt sa mga turo mo sir.sana mag tutorial kanaman sir about sa pag install ng service entrance at ang standard wire na gagmitin kng anong size po.kng pede lng po sir.salamat n advance po sir..

    • @junauxtv
      @junauxtv  5 лет назад +3

      Yes sir soon po...size po ng service entrance Conductor sir kasama yan main circuit breaker computation

    • @levikeithflores367
      @levikeithflores367 5 лет назад +1

      Oo nga please. Service entrance conductor. Yan gusto ko. Pati din po sana ung 3 phase neto. At pinaka nacoconfuse ako is merong 480/240 volts nabasa ko sa example sa pec book at di ko maitindihan yang part na yan. Thank you

  • @henryluib7249
    @henryluib7249 3 года назад

    gud pm sir. ask lang po ako? sa 3 gang switch 5 na wire na ang papasok. so ihawalay na ba yong line 1 n line 2 natin? at yong 3 return wire?

  • @nngcrtz3992
    @nngcrtz3992 Год назад

    Sir, meron kasing practice na gumamit sila ng #4 (worse #6awg) para sa 100a na main... mas susundan ko po ba ang table ni manufacturer for example 90°c 90a lang si #4, is it more correct kung gagamit ako ng #2awg na may ampacity na 115a then 100at ang main breaker? Thanks kung mapapansin...

  • @johnnyclosas8755
    @johnnyclosas8755 3 года назад

    Sakto idol...sa PEC talaga ako nababasi..kasi iba2x kasi ang wire at mirun kasi silang kanyang2x, maximum ampacity...daming nakipag talo about jan sa ampacity na yan.

  • @ayatheaclima4843
    @ayatheaclima4843 4 года назад

    Tnx boss may bago Naman akong nakuhang Aral sa tutorial mu sa mga name ng wires.. paki shout.out sa name ko Arnel clima from Cagayan de Oro. God bless u

  • @taktiknijeje3089
    @taktiknijeje3089 2 года назад

    good day po master. new subscriber here pwede kopoba malaman anung book binabasa mo fpr review saan poba makakabili nyan? salamat po sana mapansin

  • @ronaldflores8931
    @ronaldflores8931 4 года назад

    30 amp CB po ba Ang standard sa bahay na main ?. At 12mm po ba a mga outlyat 14mm sa ilaw at switch?.

  • @mcdonaldquinamot6110
    @mcdonaldquinamot6110 5 лет назад +3

    Sir Jun, saan pwede makabili or makakuha ng libro na gamit mo ngayon. Naghahanap po kasi ako ng libro katulad nalang po sa ginamit mo ngayon sa iyong tutorial.

  • @reymartcolasito6197
    @reymartcolasito6197 4 года назад +1

    sir paturo naman ng iba mo hindi ko alam mag wiring. kasi matagal ko na talaga gusto matuto pero may alam ako sa pag eelectrical 16 years old palang ako nag wiwiring na po ako😊 turo nyo naman po yung ibang hindi ko alam sainyo

    • @junauxtv
      @junauxtv  4 года назад

      Panoorin mo sir ung ibang video natin...tnx

  • @JM-pt3bn
    @JM-pt3bn 2 года назад

    bakit po sa video ng single phase aircon unit, ung conductor computation nyo po 12.5 amperes ang nakuha nyo tapos 3.5mm^2 THHN ang type ng wire ang sinabing gagamitin dahil hindi pwede ung 2.0 THHN, tapos dito sa video na to ung 3.5mm^2 THHN ay pang 30ampere? pasensya na po gusto ko lng intindihin nalilito po kasi. bakit po nasabi nyo na hindi pwede ung 2.0mm^2 THHN sa 12.5amperes ? thanks po

  • @balljack1983
    @balljack1983 3 года назад

    halimbawa 3 gang na switch di ba apat na wire un..ibig sabihin hindi pede ang wire na # 14 thhn 90'C sa 20 amp n breaker

  • @bryanpats3410
    @bryanpats3410 4 года назад +1

    good day sir saan mo nakuha o ibinase ang table mo # litecore electric

    • @junauxtv
      @junauxtv  4 года назад

      Philippine electrical code po sir...

  • @joeyparaon2682
    @joeyparaon2682 4 года назад

    tanong sir pano kung nagkasama sama na yung wire..yung thhn yung tw saka thw tpos isa lng ang CB magkakaroon kaya ng problema yun..kc now lng nalaman yang thhn,thw ska tw na yan..marami kc sa mm size na nagbabase

  • @nyquimbo2057
    @nyquimbo2057 4 года назад

    sir mas ok ba 3.5 na ang gagamiting wire sa 15amp na cb para sa mga ilaw?

  • @LocalElectricianPH
    @LocalElectricianPH 3 года назад

    Thank you master.

  • @laurotams443
    @laurotams443 4 года назад

    paano compute mo sa 22.5A / 3.5mm wire? ask ko na rin, ang main supply ko galing sa metro is 2 x 50 amp fuse sa main box, tapos sa cirduit braker 2x 30 amp, mag kakabit ako ng aircon isang window type 1HP at isang split type 1HP . sabi ng electrician gawin ko raw 2x60amp yung FUSE ko sa main box? tapos ilan amp naman sa circuit braker at ilan Amp rin sa bawat a/c. salamat sa sa sagot mo.

  • @gamerx7096
    @gamerx7096 3 года назад

    Sir jun ano po yung not more than three current carrying conductor in raceway salamat po

  • @jonathanrojo580
    @jonathanrojo580 5 лет назад +1

    Thank you sir, Jun aux TV.

    • @junauxtv
      @junauxtv  5 лет назад

      Salamat din po sir

  • @earlyboyearlyboy3920
    @earlyboyearlyboy3920 5 лет назад +1

    Salamat boss sa mga video mo God bless you pa shout out Naman boss sa next video mo Salamat

    • @junauxtv
      @junauxtv  5 лет назад +1

      State your name sir at kaunting background para maganda

    • @earlyboyearlyboy3920
      @earlyboyearlyboy3920 5 лет назад

      Earl Collano sir watching here in saudi arabia Isang hvac technician at Isang masugid na taga subaybay mo at pa shout out na din po sa family collano dyn sa camp crame God bless you sir

  • @boybravo689
    @boybravo689 4 года назад

    Boss eh kung 3 gang switch bawal na yon ksi magiging 4 na sya sa tubo ano ho ang pagkakaiba ng thw at thwn bukod sa temp. at insulation pareho ba silang solid o pareho silang stranded tnx po

  • @jomarbonador1601
    @jomarbonador1601 5 лет назад +1

    20 amp breaker ..2.0 wire ..pede ba thhn na wire ?o tw or thw lang ang pwede ?

  • @buddy6819
    @buddy6819 5 лет назад +1

    galeng mo Idol mag explain,,, nung yer version ginamit sa Philippine Electrical Code Idol?

    • @junauxtv
      @junauxtv  5 лет назад

      2017 po sir

    • @premajoey1435
      @premajoey1435 5 лет назад +1

      @@junauxtv saan po kayo nagavail then hm po

    • @junauxtv
      @junauxtv  5 лет назад

      IIEE office po sir 1200 for soft bound

    • @premajoey1435
      @premajoey1435 5 лет назад

      @@junauxtv thank you bro

  • @GarRoseMiksVlog7680
    @GarRoseMiksVlog7680 4 года назад

    Master sa sunod mong vlog kung maari lng wla ng background music or hinaan mo nde ko masyadong mrinig exlpnation mo anyway tnx sa mga vlog dami kung natutunan khit mtgal na akong electrician kya lng basic lng nae encounter ko godbless at kep up d gudvlog.

  • @albertovillaruel6100
    @albertovillaruel6100 4 года назад

    Sir tanong kolang po ok lang ba na 3.5mm thhn ang ginamit ko sa aircon ko tapos 30amp ang ckt breaker ko safe po ba yun? Thank you sir God bless

  • @erniesanterva266
    @erniesanterva266 3 года назад

    Confuse me on solid and in stranded the mm of wire is different.. Can you discuss it thank you.

  • @christophergania1607
    @christophergania1607 5 лет назад +1

    Sir jun. sana my kasamang wire at breaker pra malaman ko kung ano ka kapal yung wire at anong mga klasing wire...

    • @junauxtv
      @junauxtv  5 лет назад

      Dagdag natin sa topic yan sir

  • @damonyorgalvez1966
    @damonyorgalvez1966 4 года назад

    Paano sir kung more than 3 current carrying conductors ang laman ng raceway...ano ang magiging basehan?

  • @anganorwel3392
    @anganorwel3392 5 лет назад +1

    Salamat sir Pero wla bang prblma kapag 3.5 THHN 90'c mas ok din pag 20amps lng ginamit ko kasi THHN 90'c #12 sa c.o at 14 sa ilaw may natutunan naman ako sayo sir

    • @junauxtv
      @junauxtv  5 лет назад

      Kaya nmn ng 30 amps sir kaso un nga kailangan separate sa conduit...

    • @anganorwel3392
      @anganorwel3392 5 лет назад

      @@junauxtv Thank you sir may bago naman ako natutunan sayo

  • @ar.caisip7448
    @ar.caisip7448 5 лет назад +1

    boss dko narinig o bka nagkakamali lang ako, tanong ko lang kung ang 2.0 sa TW ay 15amp lang ang gagamitin sa circuit breaker nya?, at kung THW hnd pwedeng 15amps or kung THHN dka pwedeng mag 20amp?

    • @junauxtv
      @junauxtv  5 лет назад

      Sa 15A pwd ka po gumamit ng TW, THW at THHN na 2.0 na wire. Sa 20A na cb pwd po kayo gumamit ng 2.0mm² na THHN na wire pero kailangan alam mo ang mga bagay na dapat iconsider, like ambient temperature, kailangan hanggang 3 current carrying Conductor lang, kung sa mainit na area mo ilalagay at morethan 3 current carrying Conductor na po kayo baba na po kayo sa 15Amps

  • @kcidadlapir8488
    @kcidadlapir8488 4 года назад +1

    THHN 90°C 25 amp. Pero yong size conductor size 2.0 mm2 ibig sabihin sir hinde magbabago yong size ng wire kahit 25 amp. Na sya?

    • @junauxtv
      @junauxtv  4 года назад

      It means sir na ang kaya ng 2.0mm² na THHN 90°C na wire ang kaya nya is 25amps...pero dapat iconsider mo ung requirement nya..

    • @edwinpangilinan8077
      @edwinpangilinan8077 4 года назад

      It should be coordin ated with the type of protection you will be using. The thermal strip of an auto ckt breaker were designed to sense at a certain temp. Using a cable with higher temp rise will absorb the heat that is suppose to be sense by this strip. The result, a delayed or non tripping at all on overload condition.

  • @TairabangstV
    @TairabangstV 3 года назад

    Paanong 3wires boss 3conductors sbi mo kc pag 4wires yun yung grounding anu po b yan single phase po ba or three phase type supply voltage nyo po

    • @junauxtv
      @junauxtv  3 года назад

      no. of conductors sa loob ng pipe yan sir

  • @soyreinaavaalmorre4080
    @soyreinaavaalmorre4080 5 лет назад +1

    Pwede po makarga sa 20amps ang aircon at electric fan?

    • @junauxtv
      @junauxtv  5 лет назад +3

      Sa standard po sir kailangan naka separate ang aircon or dapat may sariling cb ang aircon

  • @philnewsvlog5183
    @philnewsvlog5183 5 лет назад +1

    Nice master Jun

  • @jaynardabinque4915
    @jaynardabinque4915 4 года назад

    Sir may tanong ako sir so pwede Gamitin ang 2.0mm² na wire sa 20A cb basta THW or THHN?
    #JunAuxTv

  • @rexwelltagumpay7709
    @rexwelltagumpay7709 2 года назад

    Ung size ng wire sir sa 15 ampher at 20 ampher sa thhn.....

  • @merlyndandoy8429
    @merlyndandoy8429 3 года назад

    Sir saan sa tatlong wire ang pinakamura?

  • @jackgomez9025
    @jackgomez9025 11 месяцев назад +1

    Sir nagturo kaba dati sa tesda santiago

    • @junauxtv
      @junauxtv  11 месяцев назад

      hindi po sir..

  • @biyahenichan2170
    @biyahenichan2170 4 года назад

    6 na switch po ba pwede sa isang ilav

  • @johnalcedo5581
    @johnalcedo5581 4 года назад

    San po pwede madownload sir yung mga tables nyo? Tulad nyan at yung electrician guide.

  • @kisuke6517
    @kisuke6517 3 года назад

    kuya pahingi ng table ng wires dapat sa isang counduit 1/2,3/4 ganun. at pede bang isama ung 2.0 at 3.5 sa isang conduit

  • @pikz357
    @pikz357 4 года назад +1

    Sir pano po pg marami ung branches ex. 45circuit nid po b n bawat circuit i 1pipe, nikikita q po kc sa iba n f 10 ang circuit ng L.O i ginagawa nila gumagamit n lng ng malaking pipe at pinagsamasama lahat ng wire, pwd po b un tnx,., po

    • @junauxtv
      @junauxtv  4 года назад

      Opo sir...idederate mo lang wire mo air

  • @saulsullano7734
    @saulsullano7734 4 года назад

    Tanong ko lng sir anong ibig sabihin ng 3 current sa raceway

  • @blackycute123
    @blackycute123 5 лет назад +1

    For ambient temp 30°C lang to tama ba mga sir?.... kasi kapag sa mainit na temp sa paligid like industrial (like pagawaan ng metal) more than 30°C magbabago ang ampacity ng wire madederate yung value ng ampacity sa table... May note ata yung table 3.10.3.1(A) sir sa baba d ko lang sure kung nakalagay Ito dun o sa iba (wala kasi ako PEC hahaha) .... thanks sir

    • @junauxtv
      @junauxtv  5 лет назад

      Yes sir sa ambient temperature of 30°C po yan sir....sa title po ng table...

  • @ejbuendia
    @ejbuendia 4 года назад +1

    Paano po pag mahaba ang wire? Di po ba magkakaroon ng power loss?

    • @junauxtv
      @junauxtv  4 года назад +1

      Yes sir....voltage drop po

    • @edwinpangilinan8077
      @edwinpangilinan8077 4 года назад +1

      Longer wires will generate voltage drop. If youre planning to use, make sure that the volatge drop does not exceed 5 per cent.

  • @johndelfin8412
    @johndelfin8412 5 лет назад +3

    sir may tanong lng aq..about sa size na ginamit gling main breaker papuntang service drop eh # 12. dn ..ok lng b un?

    • @junauxtv
      @junauxtv  5 лет назад

      Ilang amps ung main breaker mo sir?

    • @johndelfin8412
      @johndelfin8412 5 лет назад

      @@junauxtv 60 sir...

    • @junauxtv
      @junauxtv  5 лет назад

      @@johndelfin8412 single circuit breaker lang po ba sa buong bahay sir?

    • @johndelfin8412
      @johndelfin8412 5 лет назад

      ahm 6 branches sir

  • @twopiecez5226
    @twopiecez5226 4 года назад +1

    sir line-neutral ang linya kung 3 ang homerun ibig sabihin 6 wires in total sa raceway tama yun 3 conductor sa raceway PAANO naman kung line to line ang naging linya magiging 6conductor wires in total????

    • @junauxtv
      @junauxtv  4 года назад

      Magdederate ka sir example 3.5mm is 30a ang mangyayar consider asi 20a nlng ang ampacity ng wire mo

    • @twopiecez5226
      @twopiecez5226 4 года назад

      @@junauxtv so ibig sabihin mas applicable siya sa line to neutral na set up

  • @sherrylperlas8729
    @sherrylperlas8729 5 лет назад +1

    kaya lng sir jun...gusto ko rin magkaroon ng pec book...

    • @junauxtv
      @junauxtv  5 лет назад +1

      Bili na po mam sulit bayad mo sa knowledge na mkukuha mo mam...

    • @aldamilwahid1959
      @aldamilwahid1959 5 лет назад

      @@junauxtv , un sa Three-phase Boss? may idea ka? Like, paano tyo makakuha ng 380V three phase from single phase supply.
      May device ba magagamit ?

    • @torcrame4183
      @torcrame4183 5 лет назад

      @@aldamilwahid1959 meron tayo gingamit diyan phase converter from single phase to 3 phase or vice-versa...

    • @aldamilwahid1959
      @aldamilwahid1959 5 лет назад

      Un voltage frequency drive ( VFD ) , pwede kht hndi motor un load ?

    • @torcrame4183
      @torcrame4183 5 лет назад

      @@aldamilwahid1959 VFD o variable speed drive au design for motor load.. minsan tinatwag rin nmin na motor drives pwde icontrol ang speed ng motor from lower frequency to higher...

  • @marcotenchavez6670
    @marcotenchavez6670 4 года назад

    bakit ang isang presentation mo nag recommend ka ng THHN sa 1.5 HP na ACU ???? Ang THHN ay nasa 90 C . Pwede ipaliwanag ???

  • @winree5
    @winree5 5 лет назад +3

    Unless specifically permitted in Section
    240.4(E) through (G)(NEC) , the overcurrent
    protection shall not exceed 15 amperes
    for 14 AWG, 20 amperes for 12 AWG, and
    30 amperes for 10 AWG copper; or 15
    amperes for 12 AWG and 25 amoeres for
    10 AWG aluminum after any correction
    factors Tor ambient temperature and
    number of conductors have been applied.

  • @pitz10
    @pitz10 4 года назад +1

    ah kaya pala sir nakayanan ni 3.5 si welding machine na gamit namin #a breaker na 30 amp kasi akala ko pag 30 amp 5.5.
    tama ba pag ka intindi ko.?

    • @junauxtv
      @junauxtv  4 года назад

      Tama ka sir...depende pa din sa type ng wire sir

    • @pitz10
      @pitz10 4 года назад

      @@junauxtv thanks po sir sa pag confirm. dito sa dalawang bahay namin kasi yan @!g ginawa ng magkaibang electrician 30amp nilagay lahat branches tapos 60 amp ang main at ang wire lahat ay 13 mapa LO o CO.

    • @pitz10
      @pitz10 4 года назад

      sir pwedi ba dalawang .75 aircon sa isang 30 amp?

  • @levikeithflores367
    @levikeithflores367 5 лет назад +1

    Sir ung service entrance conductor na computation naman please. Single phase at 3 phase. Meron din po kasi akong nabasang example sa likod ng pec book na may 480/240v. Ganyan. Di ko magets kung saan gagamitin yan

    • @junauxtv
      @junauxtv  5 лет назад

      Meron na tayo sir... service entrance Conductor computation

    • @junauxtv
      @junauxtv  5 лет назад

      Main circuit breaker computation title

  • @catherineaysoncasiano9683
    @catherineaysoncasiano9683 4 года назад +1

    Sir kapag 30 amp cb ko po ung main cb ko ano po ung pwede na wire

    • @junauxtv
      @junauxtv  4 года назад

      5.5mm² sir or #10

  • @thomaskinglargosa9893
    @thomaskinglargosa9893 3 года назад

    Boss anong magangdang brand Ng wire??

  • @tomharrismendoza5917
    @tomharrismendoza5917 4 года назад +1

    Sir pwede pong magtanong? May circuit breaker po bang 160amps?

    • @junauxtv
      @junauxtv  4 года назад

      Wala po sir...125,150,175

    • @edwinpangilinan8077
      @edwinpangilinan8077 4 года назад

      Meron, European rating. Check with these brands, ABB , Scheider or Siemens. Di lang popular yung rating na yan kaya madalas di ini stock.

    • @bosslord3804
      @bosslord3804 3 года назад

      O

  • @xrainblake5525
    @xrainblake5525 4 года назад +1

    Sir ano mangyayari pag more than 3 conductors? Sabi mo kasi limited lang up to 3 conductors lang

    • @junauxtv
      @junauxtv  4 года назад

      Magdederate na tayo sir...babawasan natin ang ampacity ng ng wire sa Computation

  • @pitz10
    @pitz10 4 года назад +1

    sir god day ano po yung libro na gamit mo? balik ko bumili din

    • @junauxtv
      @junauxtv  4 года назад

      Philippine Electrical Code sir

    • @evangelinecamposano1588
      @evangelinecamposano1588 4 года назад +1

      Saan ba Yan nabibili. Meron ba Yan sa national book store

    • @junauxtv
      @junauxtv  4 года назад

      Wala po...mam...sa IIEE office po meron

  • @katakuricharlotte4301
    @katakuricharlotte4301 5 лет назад +1

    sir cgurado ka bng d pwede mglagay more than 3 carrying conductor sa isang conduit?bkit my chart nman akong nakita about allowable conduit fill capacities.. sample sa 20mmsq. na conduit pwede hanggang 15 na wire size 14awg..

    • @torcrame4183
      @torcrame4183 5 лет назад +1

      Allowable Ampacities of Insulated Conductors Rated Up to and Including 2000 Volts, 60°C Through 90°C, Not More Than Three Current-Carrying Conductors in Raceway, Cable, or Earth(Directly Buried), Based on Ambient Temperature of 30°C as per PEC
      As minimum only pero kung gusto natin mag-lagay posible naman may derating factor lang tayo gagamitin kung ilang# ng wires ang ilalagay sa conduit.

    • @katakuricharlotte4301
      @katakuricharlotte4301 5 лет назад +1

      my nasabi kz si sir na dpat hindi dw lalagpas sa 3 wire sa isang conduit which is wrong..

    • @blackycute123
      @blackycute123 5 лет назад +1

      PEC Table 9.1.1.1 Percent fill of conductor in conduit .... Kapag 1 wire ang nasa conduit, 53% ang max na ifill .. 2 wire ang nasa conduit 30% ang max na ifill.. Kapag 3 or more wire ang nasa conduit 40% ang max na fill of conductor..

    • @junauxtv
      @junauxtv  5 лет назад

      Hindi pwd sir kung ang susundin mo ung table na pinakita natin as per name ng table makikita nyo na po doon pero kung gusto nyo lalampas po kayo kayo sa three current carrying conductor hindi na masusunod ung table na pinakita natin kasi mag aapply ka na ng derating factor

  • @crisreitv1666
    @crisreitv1666 4 года назад

    Ung 2.0 na 25amp parang masyado na malaki po...sunog na ung wire mo dpa sya nagtrip sa breaker..

  • @rexwelltagumpay7709
    @rexwelltagumpay7709 2 года назад

    Bkt sir wlang 15 ampher sa thhn

  • @utakpinoy57
    @utakpinoy57 4 года назад +1

    Sir tanong ko lng po kung san makabili na libro ng PEC at kahit cno ba pwd bumili nyan.?

    • @junauxtv
      @junauxtv  4 года назад

      Sa IIEE office po sir...may nabalitaan ako na lep lang daw makabili pero ung kapit bahay namin nakabili sila kahit hindi sila lep

    • @utakpinoy57
      @utakpinoy57 4 года назад +1

      Ano yong lep sir ....ty

    • @junauxtv
      @junauxtv  4 года назад

      @@utakpinoy57 Lisenced Electrical Practitioner po sir...

    • @utakpinoy57
      @utakpinoy57 4 года назад +1

      Ncll holder sir lep po ba yon.?
      Pasinsya na po sir gusto ko rin ma toto eh thanks sa tutorial mo marami ako na totonan

    • @junauxtv
      @junauxtv  4 года назад

      @@utakpinoy57 NLEP po sir...Non Lisenced Electrical Practitioner sir...no problem sir

  • @joseponce9275
    @joseponce9275 5 лет назад +1

    Salamat Sir. :)

    • @junauxtv
      @junauxtv  5 лет назад +1

      Salamat din po sir

  • @raymondbarba9712
    @raymondbarba9712 3 года назад

    Sir ok yan

  • @rolandocadawas9705
    @rolandocadawas9705 4 года назад

    Meron bang madownload na book pra sa mga code

  • @macariojrmaat5724
    @macariojrmaat5724 5 лет назад +1

    Sir Pakistan elaborate Ang mm2 from 2.0 hangang SA Malaki. At ang EWG number from 14 hangang SA pinaka malaki

    • @eddieagustin4796
      @eddieagustin4796 5 лет назад +2

      awg po na ang ibig sabihin ay american wire guage na ang basehan ay ang diameter ng wire. halimbawa; yong 1.6mm na pdx ay katumbas ng 2.0 mm2 na stranded wire.

  • @blessedchristianbbc
    @blessedchristianbbc 3 года назад

    Sir thank you!

  • @edwinpangilinan8077
    @edwinpangilinan8077 4 года назад +2

    Better if you can include how these 3 types of wires hving same cross sections have different current carryinf capacities.

    • @gusomar7213
      @gusomar7213 3 года назад

      a tip: you can watch movies at Flixzone. Been using them for watching all kinds of movies lately.

    • @jedidiahwesley8522
      @jedidiahwesley8522 3 года назад

      @Gus Omar yea, I've been watching on flixzone for years myself :)

  • @fedelotero4170
    @fedelotero4170 5 лет назад

    Di ba may correction pa yon sir na minumultiply

    • @fedelotero4170
      @fedelotero4170 5 лет назад +1

      Diba may correction temperature pa yon sir

    • @junauxtv
      @junauxtv  5 лет назад

      Next video un sir para hindi masyadong mabigat....

  • @eddieagustin4796
    @eddieagustin4796 5 лет назад +1

    sir ano po ba 'yang mm squared na yan, lenght of wire, diameter , radius, lateral area or cross sectional area of wire?

  • @karljosephorcullo2178
    @karljosephorcullo2178 5 лет назад +1

    Pa, shout out boss tindero ako sa hardware electrical dami ko natotonan sayu salamat kaayu

    • @junauxtv
      @junauxtv  5 лет назад

      Salamat din po sir

  • @brandocinco2007
    @brandocinco2007 4 года назад +2

    Boss need ko matutunan computation ng wire to be used from panel to meter base and to entrace

    • @junauxtv
      @junauxtv  4 года назад

      Need mo jan sir total load...may video po tayo jan sir

  • @rauligni1999
    @rauligni1999 5 лет назад +1

    sir tanung ko lng bkit sa mga circuit breaker amps.wla naman 65.A, 85 A

    • @blackycute123
      @blackycute123 5 лет назад +1

      Mag adjust lang kung wala Hahaha example 65A Bali pwede na 60A breaker.. Sa 85 A pwede na 80 breaker :)

    • @torcrame4183
      @torcrame4183 5 лет назад +1

      @@blackycute123 meron tau mbibili na 63AT pero phirapan adopted kz ito sa IEC standard..

    • @blackycute123
      @blackycute123 5 лет назад +1

      @@torcrame4183 yes sir pero sa tingin ko d lang kasi demand sa PH yung breaker na ganun :D

  • @jrcalletor8561
    @jrcalletor8561 4 года назад +1

    Kailan mo gagamitin ang TW, THW, at THHN Sir

    • @junauxtv
      @junauxtv  4 года назад

      Soon sir discuss natin to

    • @edwinpangilinan8077
      @edwinpangilinan8077 4 года назад

      These 3 types of conductors have different ampacity and max temp rise. On what to type to consider, it is important that the designer should know the temp rise that the load or equipment will generate at the point of termination.

  • @pitz10
    @pitz10 4 года назад +1

    sir anong ibig mong sabihin na "kailangan lang pag gumamit kayo nito alam niyo yung limitation" ano ba ang limitation sir na tinutukoy mo?

    • @junauxtv
      @junauxtv  4 года назад

      Hanggang three current carrying Conductor lang sa pipe sir...para hindi maderate ang wire mo sir

    • @pitz10
      @pitz10 4 года назад

      sir salamt talaga at nag rereply ka sa amin.. pero sir di ko maintindihan ang three current, yan ba yung three phase?
      pasensya talaga gusto kulang malaman. kasi may nagamit sa amin
      30am CB na ginamit niang thhn is 3.5 which is undersize ang wire.

  • @daryl2346
    @daryl2346 5 лет назад +1

    Shortcircuit analysis at voltage drop sir para sa plans :) thanks

    • @blackycute123
      @blackycute123 5 лет назад +1

      Medyo mahaba explanation nito sir Sana magawan to ng video Hahahaha Pero maganda topic to ..Sa seminar lang kasi to kadalasan mga veteranong REE or PEE nag didiscuss nito hahahaha

    • @daryl2346
      @daryl2346 5 лет назад +1

      blacky cute hahah kaya nga sir e. Mahaba masyado ung sa pec2017 e masyado ng complikado un hahah pang mga pamg plans lng sana haha

    • @torcrame4183
      @torcrame4183 5 лет назад +1

      May SCC at VD pag residential using ohms law I do not know if Master Jun can able to prepare this type of video as the video is intended for basic tutorial in EIM 2 and basic electricity.

    • @blackycute123
      @blackycute123 5 лет назад +1

      Required na kasi SCC at VD as per DILG, DPWH at OBO(mostly City) sa mga plano( residential, commercial, industrial).. Pero yung iba municipal at city sa pinas d pa ito naiimplement sakanilang lugar

    • @junauxtv
      @junauxtv  5 лет назад +1

      Hindi ko maipapangako sir kung magawan man natin hingi tayo ng tulong hahaha

  • @alexatumanda2733
    @alexatumanda2733 5 лет назад +1

    Idol gd am/pm. Saan po maka ng avail. Ng version na ginamit mo about sa philippines elictrical code idol . slamat po

    • @junauxtv
      @junauxtv  5 лет назад

      IIEE office po sir

    • @alexatumanda2733
      @alexatumanda2733 5 лет назад +1

      Sir saan po ba sa cubao. Sir... Para maka budgetan ko po slamat po na marami

    • @junauxtv
      @junauxtv  5 лет назад +1

      @@alexatumanda2733 message moko sa Facebook page natin sir...send ko sayo map...tnx po

    • @edwinpangilinan8077
      @edwinpangilinan8077 4 года назад

      If youre a member of any IIEE chapter, they can facilitate the purchase for you.

  • @markcorpin339
    @markcorpin339 4 года назад +1

    Sir paano naman po computation sa wires more than 3 sa conduit?

    • @junauxtv
      @junauxtv  4 года назад

      Gawan natin ng video yan sir...tnx po

    • @edwinpangilinan8077
      @edwinpangilinan8077 4 года назад

      May table yan sa PEC. Dapat alam lang yung size and qty ng cables na gagamitan ng conduit.

  • @lordsenson1269
    @lordsenson1269 3 года назад

    Ser paano po mag kakaroon ng copy nyan

  • @justinlim4655
    @justinlim4655 5 лет назад +1

    Sir Pag 75°C bawal ang THHN?

    • @blackycute123
      @blackycute123 5 лет назад +1

      HH meaning High Heat bali mataas ang temp na pwede niya ihandle

    • @blackycute123
      @blackycute123 5 лет назад +1

      Pero parang may ganyan din ako nabasa ginamit nya ay 5.5mm2 THHN 60°C sa mga Plano o kaya sa mga babasahin sa site :)

    • @torcrame4183
      @torcrame4183 5 лет назад +1

      You can use either 75oC THWN or THHN 90oc as long the breaker rating ay appropriate sa size ng wire.

    • @junauxtv
      @junauxtv  5 лет назад

      Sa mga nakakaalam correct me if I'm wrong...
      Pag TW ang temp na kaya nya is hanggang 60°C
      THW- 75°C
      THHN-90°C

  • @diezeljacla8500
    @diezeljacla8500 3 года назад

    Boss pwede makahingi ng pic nyan boss yung allowable ampacities pri print ko lang boss salamat

  • @erwinbayron5889
    @erwinbayron5889 4 года назад +1

    sir bakit iba yung wire size ng PDX wire

    • @junauxtv
      @junauxtv  4 года назад

      Pano pong iba sir?

    • @erwinbayron5889
      @erwinbayron5889 4 года назад

      @@junauxtv kc sir yung # 14 ng thhn dpat 2.0 yun eh SA PDX 1.6mm lng

  • @blessedchristianbbc
    @blessedchristianbbc 3 года назад

    Pwede makahingi ng copy mo ng blue paper thank you!

  • @christopherfrencillo1748
    @christopherfrencillo1748 5 лет назад +1

    Sir pano po ang computation ng length ang size ng wire

    • @torcrame4183
      @torcrame4183 5 лет назад +1

      @ Master Jun may bago ka na naman topic na gagawin related sa tanong.☝

    • @junauxtv
      @junauxtv  5 лет назад

      Sir chris try natin gawan ng video sir...

    • @junauxtv
      @junauxtv  5 лет назад

      Oo nga sir Tor Crame kapag ngrereply ako ng comment may notebook ako sa tabi ko sinusulat ko ang mga topic na suggested ng viewers..

    • @torcrame4183
      @torcrame4183 5 лет назад

      @@junauxtv actually alam ko yan pero gusto ko ikaw magprovide sa knila. 👍