HVAC/R: How To Pull And Clean Strainer On Water Cooled Equipment (Step by Step)

Поделиться
HTML-код
  • Опубликовано: 14 окт 2024
  • HVAC/R: How To Pull And Clean Strainer On Water Cooled Equipment (Step by Step)
    Follow me on instagram! @JumperManTech
    For all inquiries please E-Mail: JumperManTech@Gmail.com

Комментарии • 58

  • @gnasty30
    @gnasty30 2 года назад +3

    Good attitude dude I super appreciate the learning experience and I hope you’ve been living a good life man

  • @izzybell11
    @izzybell11 5 лет назад +4

    Glad 😄 to see a new video !!! Didn't hear from you for a while. As always well done 👍

    • @JumpermanTech
      @JumpermanTech  5 лет назад

      I'm back like I never left😎 Haha
      Thank you very much👍 New video every week

  • @jones32blessed22
    @jones32blessed22 Год назад

    Mann need more of these! On water source equipment. Thanks

  • @unlimitedmahdi1332
    @unlimitedmahdi1332 Год назад

    It was very informative and helped me a lot in chiller maintenance. Thanks for taking the time to make this video.
    Can you introduce me to a reputable institution where I can take chiller maintenance courses?

  • @eurysgamez9554
    @eurysgamez9554 11 месяцев назад +1

    Whats average cost to replace a 2.5 or 3 ton water cooled air handler unit?

  • @tedharrison4109
    @tedharrison4109 2 года назад

    That was nicely done. Do you have any showing how to drain a condensate drain line and pan from a water cooled apartment HAVC system in a Condominium or Apartment building. One with a central cooling tower for all the units ? We have constant problems with the condensate pans overflowing inside apartment units because the drain line constantly gets clogged with "snot".

  • @Johnomosquito10
    @Johnomosquito10 4 года назад

    Don't forget to throw a lock on that disc my dude. You never know...
    Dope video btw and much appreciated !

  • @nicolerennie
    @nicolerennie 5 лет назад +6

    making dirty work look clean⚡️

  • @kevinlarson3996
    @kevinlarson3996 5 лет назад +4

    Nice video keep them coming.

    • @JumpermanTech
      @JumpermanTech  5 лет назад +1

      Thank you so much Kevin, much appreicated. Comments like yours keep my motivated and give me energy. Hope you had a good weekend and have a great work week. Let's get this $

  • @aarongray503
    @aarongray503 6 месяцев назад +1

    Don’t you have to purge the air out before you screw cap back on?

  • @dsadventures6699
    @dsadventures6699 4 года назад

    Nice video, thank you, question What type off strainer is that and where can I buy one

  • @renecuevas4128
    @renecuevas4128 2 года назад

    Sorry to hear about ur tools I worked in miami also and had to chain the ladder u kno ...tnk u

  • @holidaypapi7392
    @holidaypapi7392 Год назад

    Bro can you make a video on on how to clean a chilled water Fan coil unit.

  • @alsur272
    @alsur272 Год назад

    Thank you for tutorial . But dude do you know meaning of your tattoo?

  • @sertacsilbastan
    @sertacsilbastan 3 года назад

    Hi there! Thank you for the video and step by step explanations. I was actually looking to learn how to flush in-unit HVAC systems, since my building has cooling towers but we also have seperate units in each room of the apartment. They used to do the maintenance regularly but since Covid started, we never invited them over. So now I have two units blowing out room temperature air, instead of cold in the summer or warm in the winter. I used to watch the guys do the maintenance but my memories are kind of blurry. My question is, is there a quick way for you to explain me how to do it? I see two valves when I open the AC box inside the wall. I don't know which one is for the incoming line and which is for the drainage. I also don't know whether I should close the two valves before I start 😓 I'd really appreciate it if you could kindly give me a couple of tips that may help me in this cold winter days! Thanks a bunch in advance 🌟

    • @minas.a.4393
      @minas.a.4393 3 года назад

      did you ever fix this? I have the same problem happening now

    • @sertacsilbastan
      @sertacsilbastan 3 года назад +1

      @@minas.a.4393 Hello. Yes, I actually flushed the units by turning off the two valves first. Then detaching the outgoing line from the valve, finding a large enough bucket to collect the dirty water coming from the hose, and opening the incoming line's valve. There's significant water pressure, so I'd suggest anyone to be very careful about the entire process. Once the dirty water starts coming out clean, you can then close the valve and reconnect everything back. Once everything is tightly secured, open the outgoing valve first, and then open the incoming water line. The incoming water line is the one that goes directly into the unit, and that's how I figured my layout. Hope this helps!

    • @minas.a.4393
      @minas.a.4393 3 года назад

      @@sertacsilbastan thanks! That is what I am planning to do.. but I’m not strong enough to take off the cap! Hahaha

    • @sertacsilbastan
      @sertacsilbastan 3 года назад

      @@minas.a.4393 a wrench would help :)

    • @hvacmania8323
      @hvacmania8323 2 года назад

      @@minas.a.4393 I will take it off for ya 💪

  • @ÐÞæ
    @ÐÞæ 4 года назад

    Thanks for your always nice to watch videos bro.
    I'm sorry to hear about your tools; if you could use some help getting new tools, would you have an Patreon available?
    Compliments about your editing skills and music choice at the end :-)

  • @binineziri7599
    @binineziri7599 3 месяца назад

    Great Video 🎉

  • @zachburgess6064
    @zachburgess6064 Год назад

    Why didn’t you purge the air out? That system didn’t have a pump? Just out of curiosity. I’m still in the process of learning chillers, towers and water source heat pumps

    • @3cats932
      @3cats932 11 месяцев назад

      Condenser water pump and cooling tower
      I believe the air vents are tied into the main condenser water loops somewhere in the building.
      Some water valves or strainer housings have manual air purging ports.
      Water pumps and cooling towers are required for water source heat pumps /AC systems

    • @3cats932
      @3cats932 11 месяцев назад

      Rule of thumb
      On WSHP
      Outlet water temperature - inlet water temperature = 10 degrees or lower
      95 (Out) - 80 (in) = 15 degrees [dirty strainer or clogged up in the condenser water lines)
      Higher than 10 = dirty strainer

  • @BBLombardi
    @BBLombardi 3 года назад

    I know it’s been a while but thank you!

  • @Johnomosquito10
    @Johnomosquito10 4 года назад

    My man!
    Nicely done

  • @julienng8045
    @julienng8045 2 года назад

    Hey thanks Mann.. I'm feel inept at opening the strainer for chambers as I couldn't use the exact force and it drains out my energy for a whole afternoon for this shit🤣

  • @anilksingh650
    @anilksingh650 2 года назад

    Thank you for your time informative video

  • @krazieboy03
    @krazieboy03 4 года назад

    How often should a strainer be clean?

  • @tresmoore6199
    @tresmoore6199 5 лет назад +4

    Sorry to hear about your tools bro. I've been there. It's like taking money right out of your pocket.

    • @JumpermanTech
      @JumpermanTech  5 лет назад

      Ahhh man it happens working in large buildings with multiple contractors. Especially in the city. Just cant leave anything unattended. Thank you for your words and I totally feel that. These tools are my bread & butter. Just trying to make an honest living out here. Hope you have a wonderful weekend and let's do the right thing👍

  • @exterminator4808
    @exterminator4808 4 года назад

    Came to know about the strainer's existence in this video! 👍 Too bad about your tools. ☹️

  • @ares3914
    @ares3914 2 года назад +2

    That's messed up about your wrenches getting robbed. I work in the city every day to and can't leave anything unintended and can't trust anyone. Hope your company got your back and helped you out at least. Your a journeyman and a good one at that. They should help you out. If not they cheap as hell and remember there's hundreds of companies that will take care of you if your a good tech.

    • @renecuevas4128
      @renecuevas4128 2 года назад

      I agree good tech or I ll good mechanic. Sorry about ur tools I worked in new york also and was aware of tools disappear quick.....sorry that happened to a good working guy

  • @chelsea08FC
    @chelsea08FC Год назад

    Beautiful 🤩

  • @geraldschilli8870
    @geraldschilli8870 3 года назад

    Those strainer caps are usually sealed with a rubber o-ring. Why do you need Teflon tape. Get a new o-ring & then you won’t have overtighten that strainer cap.

  • @babaolowo35
    @babaolowo35 Год назад

    THANKS

  • @Gothiclovesick
    @Gothiclovesick 5 лет назад +4

    Dirty strainer = High head pressure

  • @adityadhiman6962
    @adityadhiman6962 3 года назад

    What isthe location of strainer

  • @armandorodriguez6447
    @armandorodriguez6447 3 месяца назад

    4:52 a fly spoke and said???

  • @lesupernick21
    @lesupernick21 5 лет назад +1

    Purging the air? You know in these buildings the air vent never works.

    • @JumpermanTech
      @JumpermanTech  5 лет назад

      How do you know they never work in these buildings lol Need to do it manually yourself to be safe

  • @sebastianmendoza1240
    @sebastianmendoza1240 4 года назад

    Why are you using an 18 " Wrench to take off a plug....

    • @JumpermanTech
      @JumpermanTech  4 года назад +1

      In my video I mentioned that someone stole my adjustables so I had to use what I had at the time. Haha I know, its looks ridiculous but you need to do what you have to so that job can get done👍 Thanks for watching. Be safe👀

  • @davidfloyd6084
    @davidfloyd6084 6 месяцев назад

    sucks you got your stuff stolen. worse feeling ever. just a tip. you can add a garden hose connection with a cap on the end where the cap is and connect a hose and back flush the unit and reclean strainer. allows you get get all the debris in the condenser loop. not a huge problem on copper pipes but if they're using black pipe anywhere in that building or anything other than brass or copper. lines get nasty really fast especially if the tower isn't treated on a regular

    • @alexanderzhao1457
      @alexanderzhao1457 2 месяца назад

      hi david, im really interested in this tip. So you connect a hose to the cap and shoot water through the cap to "backflush"?
      wouldnt this be the same as if the inlet water was just running?
      as in the hose water is now effectively your inlet water
      then you remove the hose and let it drain again?
      this would remove more debris than just draining the pipes after closing the valves?

    • @davidfloyd6084
      @davidfloyd6084 2 месяца назад

      @@alexanderzhao1457 basically the hose is just a drain down to a barrel to collect the water. close Entering water valve and open return water valve. and open drain valve for your drain hose. it forces all water through the unit and the strainer and out the hose. drain it til water is clear, after which close return and open entering. water coming out should be comparable to the return. if you open return and barely anything comes out or resembles a sink faucet you have a restriction. most likely due to strainer which will need to be cleaned but ive had it clogged up at the inlet or outlet connections on unit or inside the condenser loop itself. after youre confident the system is clear, clean the strainer and put unit back in service.

  • @ares3914
    @ares3914 Год назад

    Looks like someone went heavy on that pookie last time they cleaned it.

  • @kylepratt1805
    @kylepratt1805 3 года назад +1

    mashine

  • @ZeEnderCat777
    @ZeEnderCat777 9 месяцев назад

    RIP to your tools, bro :(

  • @Gretathunbergsfart
    @Gretathunbergsfart 5 лет назад +1

    I was about to say you needed more torque on that bleeder valve

    • @JumpermanTech
      @JumpermanTech  5 лет назад +1

      Lmao! Brought out the big guns! Someone stole my adjustables that day 😭

    • @Gretathunbergsfart
      @Gretathunbergsfart 5 лет назад +1

      Jumper man Tech keep your Chanel locks on you at all times!

    • @JumpermanTech
      @JumpermanTech  5 лет назад +2

      @@Gretathunbergsfart Sir yes sir! Never again will I leave my bag unattended but I cant guarantee I wont forget them inside of a unit and find it a year later 😂 Thanks for the funny feedback. Thanks for watching 🙂