100KW Solar Plant | installation Quality | Good Practice | Equipment Rating
HTML-код
- Опубликовано: 16 ноя 2024
- #100kw #SolarPlantInstallation #SolarO&M
Hi, If you are targeting Solar Industry jobs in Dubai , then this might be "SUPER helpful"
Learn all About Solar Plant DATA analytics & advance report creation:
www.udemy.com/...
Digital CV creation for Dubai JOBS on Solar PV Industry:
www.udemy.com/...
For Questions/Technical / Solar Course Training support connect with me.
Linkdln:bit.ly/3xG9tQX
Subscribe:bit.ly/2XoCPH8
Linkdln:bit.ly/3xG9tQX
Instagram:bit.ly/3jLSV5e
Facebook:cutt.ly/JQDl7Ba
Quora:bit.ly/3iFvM4X
Telegram Solar Group:bit.ly/3iFC2d9
Twitter:bit.ly/3iEYdQw
IMPORTANT Solar Videos
SOLAR DC cable MEGGER TEST - • SOLAR DC cable Insulat...
Solar DC Cable management - • Solar DC cable Managem...
1500VDC Solar Plant - • 3MW Solar Central Inve...
Solar Plant Thermography - • solar plant thermography
Wrong PR%😭 What to do?? - • Solar PR% issue | Sens...
Solar Plant SECRET - • Solar Plant SECRET , ...
Tilt 📐/ Orientation📈 without PvSyst - • Tilt / Orientation wit...
Solar☀️ Plant 🔺 Thermography❗ - • solar plant thermography
Solar 100kw Plant , perfect installation - • 100KW Solar Plant | in...
Solar Plant power Factor🚫- • Solar Plant | Power Fa...
Solar Plant Specific Yield ?? - • Solar Specific Yield ?...
Solar Plant AC/DC earthing ? Why - • Solar Plant Earthing |...
Solar 🌞Net Meter Fault Solution - • Net metering Import v...
Solar 🌞 PID LOSS 📉♻️- • PID loss in SOLAR Pane...
Solar Plant Measurements - • Solar Plant Measuremen...
Solar Plant 🌞Ground Fault - • Solar Plant Ground Fau...
Solar Inverter Derating 🔥- • Solar inverter Deratin...
Solar Plant Overheating Issue🔥- • Solar Plant Over heati...
Solar Eclipse 🌞🌜Genration Analysis - • Solar Eclipse Genratio...
Free Pvsyst software Book ♻️- • Free PvSyst Documents ...
Solar Plant money Payback Calculation 💵- • Solar Plant Money Retu...
Solar🌞 plant LA earthing Calculation in हिंदी में♻️- • Solar Plant LA selecti...
Types of Solar🌞 cell Fault👨🏻🔧 हिंदी में - • Types of Defects in So...
Solar🌞 inverter Selection calculation👨🏻🔧 हिंदी में - • Solar Inverter Selecti...
Solar 👨🏻🔧Parking 🚕Installation 👨🏻🔧 हिंदी में - • Solar Parking | Cost |...
Solar tilt angle & Azimuth experiment🔅- • Video
Middle East Energy expo🔅♻️- • Middle East Energy exp...
How to use PVSYST software🖥️- • Video
Solar AC cable sizing Calculation👨🏻🔧- • Solar AC cable sizing ...
Solar DC CABLE sizing Calculation👨🏻🔧- • Solar DC cable calcula...
Solar DC earthing systems Calculation👨🏻🔧- • Solar DC earthing calc...
Calculate Solar Plant PR%🌞- • Calculate Solar plant ...
SOLAR PV modules comparison🔅- • Calculate How to Selec...
Solar Earth pit resistance Test 👨🏻🔧- • Simple Earth pit resis...
Best Solar panel 🌞cleaning method part 1 - • Best Solar Panel clean...
Best Solar panel 🌞cleaning method part 2 - • Best Solar Panel clean...
Renewable energy India Expo♻️- • REI Renewable energy I...
Solar DC👩🔧 string Fault Rectification method - • Solar DC string curren...
How does solar panels catch fire🔥- • Solar Cell Hotspot, कै...
Solar cell working in Hindi🌞- • Solar Cell Working in ...
Rooftop Solar plant visit🌞- • Understand solar plant...
How to check Solar Delta Inverters👩🔧- • Delta Solar string inv...
Solar Plant thermography test 🔅- • Thermography test of s...
This panel can put out close to 100 watts ruclips.net/user/postUgkxOqI2yqX0XVrhR2BMJciTWrHJpG8FhJyg when positioned in the appropriate southernly direction, tilted to the optimal angle for your latitude/date, and connected to a higher capacity device than a 500. The built in kickstand angle is a fixed at 50 degrees. Up to 20% more power can be output by selecting the actual date and latitude optimal angle.The 500 will only input 3.5A maximum at 18 volts for 63 watts. Some of the excess power from the panel can be fed into a USB battery bank, charged directly from the panel while also charging a 500. This will allow you to harvest as much as 63 + 15 = 78 watts.If this panel is used to charge a larger device, such as the power station, then its full output potential can be realized.
Recently I have completed my 129kw Solar ICE Factory Project I have used all these protection devices in that plants thanku dear for supporting
Can you plz share the wire diagram with me... My whats alp no is 0092.3338307383.thanks
Bhai 129 ke ki costing bata sakte hai aap?
Can get ur no. munesh sir
Bro gove your number please
@@tolerabletroll5500 what is the cost of the installation?
Dear Sir, after 10 years people will remember you that you have provided very useful information which a common electrician /engineer does not get until he enter in a solar plant. thanks a lot. best wishes for the channel and your honest way to impart knowledge.
Thanks for the support brother
sir , watching your video after three years ..i must say i havent seen such an informative like this before ...i got to know everything..
I have never seen plant like this sir.
Secure and accessible.
Love from varanasi (mahakal ki Nagari)
Thanks for the support
I am working on 10 MW Solar plant.but i am new in this field. And getting so much valuable knowledge . Because of You ..
Thanks for the support
Kaha pai ho aap
@@maheshvetal7780 ap mere sain puch rahe ho kya ?
@@WorldOnWheelsBaby yes sir aapse puch raha hu
Maira bhi isme interest hai aapse kuch bat krni thi aap contact number do na please
Dear sir darasal you tube pe yahe sab knowledge dene ke jarurat hai you tube pe pata nhi log kya Kya krte rhte hai mai app ka all video dekhta hu aur dekhne phle like krtahu😂😂😂app ke pass good knowledge hai And good practical
No one else looks like you on this youtube solar power system love you sir
Thanks for the support
Sir, I really hope next time you can make videos in full English or with subs. Your video looks very interesting and I wish to learn from them in the future
Definitely
Happy to see your Videos, very informative. Sharing your expertise is really helps to us.
Pros:
Genuine information
Bench mark standards
Video and audio quality is very good
With Reall plants
This charming guy has both knowledge and experience.
Cons: I have found nothing.
Suggestions: please try to explain in English also..
Requests:
1. Please do a Video on structure related information for rooftops with elevated structure. With all details like which type of structure, structure material, quality, standards. Wind withstand capacity of the structure. Best practices.
2. For panel and structure fixing which Nut&Bolts can be used and what are the bench marks.
3. Distance between Panels and DCDB and DC Wire guage based on the distance.
4. If possible show even small plants like 50kw or 20kw
Thank You So Much for your Videos.. very informative..
Thanks for the support ❤️
Super himanshu ji ap knowledge Free me sher krte ho bahot hi Achaa work he apka
Thanks for the support Anand 🙏🏻
Thanku sir really you are genius in this field....
Thanks for the support
@@SustainableEveryDay tnx sir
How to connect it further to transformer
Very good
Many many thanks Mr. Himanshu reveri ver y nice explaining completely safe and great iformation . I appreciate you and thankyou very much .
himanshu you really make a super contribution .....all the best man...and thanks a lot
Plant installation toh jabardast hai... Nice information also from you ( Sir )...👌👌
Thanks for the support
Good step for new Qamar
Excellent dear,
You are my guru ji.my growing up skills are learning from your videos.and your whatsapp suport.and am also waiting for detailed zero export device video.bro.
Very soon
Bhai thank you for helping us!!
Through making this type of quality video of solar. I wish u make more and more video on daily basis so i can upgrade my self. Thank you very much sir once again..... 😇
Thanks for the support
Thanks... Kindly suggest why not use dcdb box or DC spd??
I'm a fresher in this field and going to install 1.5MW project
Excellent. Superb. Very very, worth full informative video . Thanks for making this video
Finally video upload kiya sir apn e bhoout dino k baad👍👍👍👍👍👍
Bilkul Vishal bhai , bohot din ho gaye the , bohot busy tha mai
Sir ZUNSOLAR kaisa hai? Mere pass Luminous ka 165wp ka 1 panel hai & 3 aur lena hai. Zunsolar kaisa rahega. Please reply
It will be good
Welcome🎉
sir 50 50 Ke Do banaa hai lekin AC ka aap ne bas bar 100 100 amp mcb kitne kv ki h aur dono invetr ac line milade h kya bo fhald nani hoge koi kam koi jyada dono brabr voltej kese nikalega muje bataye sir
Sir your walk step measurement is so accurate, 😜
1-2-3...total 3m😜👏👏👏
So Good informative video
Thank you so much bro💐
Thanks for the support
@@SustainableEveryDay My pleasure💐🥰
Very informative video related to installation
Thanks for the support
@@SustainableEveryDay i am going to install 700kw in Pakistan Insha Allah may be i will take some advice from you if you have time
Well defined informative vlong bro for new learning engineerings and students thanks alot brother keep shining.
Himanshu bhai , great job.
Bhai please explain the HMI Parameters of Sungrow inverter
Surprisingly All DC cables are directly connected to SG36KTL without any protective device like DC Breakers/Fuses DC SPD۔
Surprisingly all these DC protection now comes inside the inverter
Dc Protection k liyeh kuch safety Dc Box like safety fuse breaker use nahi kiya ???
Should we install topcon bificial module on metal roof?
Solar Module and structure ki earthing or DC SPDs ko aik earth k sath connect kr sktay hain?
Very informative video. Namaste hatsof to you bro.
Highly appreciated your clip.Please explain why Ac and Dc earth pits need to be isolated.As per BS 7671,should not be one combined earth bar where AC and dc earth are connected together in order to avoid potential difference between ac and dc earth bars.
thank you so much for sharing basic knowledge brother
Thanks for the support
Thanks a lot Brother. Deserve more views and Likes.
Sir please make video on dg backgeed protection system
Best explanation ever ♥️
Thankuu sir
Thanks for the support
Sir really amazing work 👍
Thanks for the support
Very nice lecture on solar panels good practices
Thanks for the support
sir please makes a video about all types of continuity test of INVERTER, and how much value needs to comes in seperates case like IGBT, DC contactor, ac contactor, capacitor value etc.?
Pls suggest which one is best clampmeter for chacking dc ampeare!
Beautifully explained
Thanks for the support
Thanks sir..... please share MW scale video....like this....
Very soon
Ye batao aap Enphase micro inverter lagwane ka faeda h kuch.
Bhai sateek se bhi sateek content...thanks
I have already face problem from mc connectors and properly take care of it.
Exactly
Jabarjast sir ji ❤️❤️❤️❤️❤️❤️❤️👍👍👍👍👍👍👍👍
Can we install 110kw solis inverter without Netmetering? With using smartmeter to control zero export.
Very good practice bro 👍
बहोत खूब व्हीडिओ 💐💐
Thanks for the support
Bhaiya your video are very knowledgeable,high level of knowledge and perfection. Sir any wifi device for bidirectional energy meter apart from discom meter. Please suggest.
Very informative and knowledgeable video.
Nice
Thanks for the support
Thanks sir very good👍👍👍information
When you installing panels on tin sheet roof,facing east -west,are you installing the panels the way you showed in the viedeo or are you rotateing the panel to face south by modifying the structure ?
Sir pleg mara ak dought h
Hamara dc side 100kw ka plant h too vaha ac side kitna kw jarnate kara ga
Good knowledge himanshu bhaiya
Thanks for sharing valuable information ,sir
Thanks for the support
@@SustainableEveryDay jenab I am from jammu and kashmir and working in government sector ad electrical engineer in power development and done Mtch in power and btech electrical from NIT calicut and at present also pursuing certified energy auditor with one paper left from BEE, Kindly guide how can grow myself in energy auditor field, rest yours video was really 10/10
This video is very good but i have one Question why not installed Earthing Arrested road on roof top
Not required as per DEWA standard , they follow British Electrical code
ap nay DC side pay Breaker ya fuse q ni use kiye?
consider narrating in English so you can get more viewers to watch, very interesting i really wanted to hear
Yehh really sorry will add the subtitles
How is polycap copper cable armoured for cable requirements secondly goodwe inverter and which company mono module should be installed
Great very useful thanks
Thanks for the support
Masha Allah that’s great 😍👍
Thanks for the support
Dear sir, ek question hai 5kw inverter single phase hai, poly ke 9 panel(3kw) system hai, acdb me ac side voltage (inv off hai) 228v aa rahe hai,
dc side 388 v hai, inverter on condition me(inv me or acdb me ac line me voltage 277 bata raha hai ) or n + earth 24 bata raha hai, hum yahi karn janna chahte sir inverter off hai tab ac side line me 228v bata raha hai, jab inverter on karte hai tab volage 277 bata rha hai ????? please rply
behtareen
Thanks for the support
Why did you not use DC side safety protection ?
Please show DC side protections
Thanks veer ji (brother)
Thanks guru ji u are great
Thanks for the support
Really appreciated 🙏 your efforts and way of explanation 👏
Thanks for the support
Sir which is best suited solar panel module renewsys or longi whis is best that we select please guide
Very helpful video sir
Thanks for the support
Sir maintenance par ek video bana dijiye .
Banaye hai bro
ruclips.net/video/yTw-c33Vxqo/видео.html
Although not in English, the video was informative.
Please try to speak in English, because I think your followers are from all over the world :)
Thank you very much!
Your give really good information 🙏🙏
Thanks for the support
Hi sir, Its very helpful ,Still i have one drought i.e Please discuss how to do the cable connection between the strings/Module
Sure in next video
Sir Kindly Explain about connection Diagram of Interface Protection System Unit?
Thank you so much sir sharing this informative video and grow my skills...🙏🙏👌🏻👌🏻
Thanks for the support
Bohat aci baty btey ap n
Great information. Keep it up.
Thanks for the support
Always 👍🏻
Very Informative Video, Thanks
Thanks for the support
Very Very Excellent Jai hind Sir Super
Dear sir yi proper work ky sy karta q k pannel k Ly tielt angle zarori hai
Sir 4 batteries series mein hai
Charging current kia ho ni chachai
200ah ki battery hai
250w k panel
Very great informative video thanks
Thanks for the support
thanks alot sir for ur valuable information
Hi sir pls make a video which we should use in longi hi mo 6 vs jinko N type
Very best video thanks bro❤
Great work.can you plz share wire diagram of Ac distribution box. It would be very informative for us. Thanks
Very good information sir.
Sir great practice Video ....
Thanks for the support
Bhai ma on grid tied 20 kw system lga raha hon on grid system ma grid off hony py system off ho java hy to kia koi 1 phase grid say na any py bhi system off ho jata hy
Really it is very informative knowledge dear thanks for sharing .
Thanks for the support
Allah bless you bro..very informative video..
Thanks for the support
Sir,ager Kisi string may ground fault ho Jaye tab string fault Sahi kernay Kay liye sabsay pehlay D.C.d.b ya inverter off kertay hay ya A.C.D.B .
Inverter , because string Inverter mai DCDB nahe lagta
Thank u sir,a valuable vedio
Thanks for the support
Sir ,,, Ground Mounted and Rooftop metal shit me Ganeretion ka kitna defferent hota hai
It will depend on site conditions , such as orientation tilt site issues , both can be good and bad at the same time , but it tilt and azimuth is same , ground mount will generate 5% extra than rooftop , but installation of ground mount will always be costly with respect to rooftop
superb
Thanks for the support
Nicely explained. Layman can work with it
Very good information