inverter ac outdoor dc motor repairing
HTML-код
- Опубликовано: 8 сен 2024
- Hi Friends welcome to ELECTRIC LOCHA
My Gmail ID : - raj2324300@gmail.com
All about of this video
Friends, in this video we will show you repairing the fan motor of the outdoor unit which is a BLDC motor. This motor runs at 320 volts DC and it needs 15 volts to run and 2-6 volt also. We had also made a DC motor adapter which can run any DC motor Indoor unit as well as outdoor unit fan motor. this outdoor dc motor is not in working and it is a inverter AC outdoor fan motor which is not running . Let us see what we have to do and what is right or not, also you will get to see in this video how to repair a DC motor. If a dc or pg motor is not working, what to do how to supply a DC motor. what is not going , what to do, all these will be answered in the this video.
Jai Hind
दोस्तों, इस वीडियो में हम आपको आउटडोर यूनिट के पंखे की मोटर की मरम्मत करते हुए दिखाएंगे जो कि BLDC मोटर है। यह मोटर 320 वोल्ट डीसी पर चलती है और इसे चलाने के लिए 15 वोल्ट की जरूरत होती है और 2-6 वोल्ट की भी। हमने एक डीसी मोटर एडॉप्टर भी बनाया था जो किसी भी डीसी मोटर इंडोर यूनिट के साथ-साथ आउटडोर यूनिट फैन मोटर भी चला सकता है। यह आउटडोर डीसी मोटर काम करने में नहीं है और यह एक इन्वर्टर एसी आउटडोर फैन मोटर है जो नहीं चल रही है। आइए देखते हैं कि हमें क्या करना है और क्या सही है या नहीं, यह भी आपको इस वीडियो में देखने को मिलेगा कि कैसे डीसी मोटर की मरम्मत की जाती है। यदि डीसी या पीजी मोटर काम नहीं कर रही है, तो डीसी मोटर की आपूर्ति कैसे करें। क्या नहीं हो रहा है, क्या करना है, इन सभी का जवाब इस वीडियो में दिया जाएगा।
जय हिन्द
subscribe this channel
so friends thank you
Face book : www.facebook.c...
Instagram : www.instagram....
Thanks
Thank you sir
الله بنور عليك يا هندسه على الفن الجميل يا ليت كل الفيديوهات تشرح كارتات ثلاجه وتكييف انفرتر لان شرحك مبسط وترمجه فيديوهاتك على لغه عربيه
Good
Thanku SIR🙏
Perfect
very good job sir
Sirji daikin inverter split ac ,on hone ke baad outdoor compressor on hone ke baad indoor restart hota hai , har 3min mein
Voltes tast koro
apki video ka bht intezar karta hun me #smarttechskill
Very good information thinks Bhai sahab
Good tiching welcome 👍👌👌👌👌👌👌👌👌👌👌👌👍❤️🔥🎉
Perfectly Explained 👍
Raj bhai thanks.
Nice video 👌 sar ji
Great work sir ji
Sir foult dhonda kesy ye bhi btaya kreen
Great knowledge
Sir ye batiye indoor ki pg motor ko outdoor inverter pcb ki testing ke liye use kar sakte hai
Very good video
Very good video sir ji.
Excellent sir
Nice video
Good work
Very good job
nyc,,,,, jai hind ja Bharat
jai hind
Good thanks bro
Good job 👍🏾
Thanks bro !
Raja ji super ji.......Kamal karta ji.....aap na no de deyo j ho sake ta aap ji nu mil lange..... jeet Delhi toooooo 😊
9213717087 call us
Dada good information sir.ak clamp metre best quality good range mein suggestion dijiye please ❤️❤️❤️❤️❤️
اللهم صل على سيدنا محمد وعلى آله وأصحابه أجمعين
Bahuchar Airconditioner bopal Ahmedabad Gujarat , sir 310 v dc 250w 860 rpm vala cirkit kaha milega
Bluestar 12 ho ka outdoor motor hai.
Amazing 😍👌
Jai hind jai bhart
Jai Hind
Awsome
Nice
v nice bro
Jai ho
Sir round side kesy chang karna hai
Thanks
Can 2 Timer Blink error in o general because of outdoor fan wiring connection
Excellent. Non inverter AC carrier Godrej
Agar non inverter hogie to DC motor kaisi lagegie bhai. Ye non inverter units mein nahi atie.
@@mujeeb7100carrier compani cycloget model
@@mujeeb7100 if you send your phone number .we send you video that non inverter unit out door fan motor DC .
Sir inverter compressor ko direct chalny ka pcb bnaeen asaan wala
Sir micro controller k kon say pin par 5volt check krangai.. Or agr micro controller k pins par aap nay video bnaye tho bht acha hoga
Sir o general ac hai indoor fan motar chal kar powar chod deta h
Sar agar aap kisi bhi video mein tu usi samay usmein video ka window aana chahie jo ki usko dekh sake 🙏
Sir,
इन्वर्टर ऐसी के आउटडोर का PCB खराब होने पर क्या कंप्रेसर को डायरेक्ट करके गैस बैक कर सकते है।
Power sup lay I box
Very very nice💯
Sangi
Sir Aap dc inverter Ac Ki outdoor moter bhi theek karte ho kya
ji karte hai
Sir ap ny motor aur adapter ki pin ko joint ky liye dieod Kyu use ki hain.kindly reply.
Diode nahi hai big bro sirf pin hai
Sir ap ny inverter tester ma Led kitney mm ki use ki hain
Raj g agar voltage drop hota hain toh kya problam ho skti hain sameer bhajanpura
microcontroller kharab hota dear sameer
@@electriclocha thanks g
Pasand, nahi bhahut acha hi sir vedio
Sir ek ipm bna kr de skte ho. 120v input, of 3phase induction motor
Sir ek ipm Maine bhi bnaya hai aap ki video dekh dekh kar jo maine check bhi krwana hai MOSFET heat hoker damage ho jate hai please contact me Satish Kumar-9466278470,7015064272, please send your courier address
Big bro aapne Jo ipm banata hai uski pic mail ker do
Kaha milga kharab motor mujhe dc banaya hai sir
Ye motor ka upar ka nut kaha mil jayega sir
Sir ye motor ka wattage kya hai? Pls bataye. Thank you.
Bhai motor repair kr doge kya
Hitachi Indoor dc motor is not run on 320DC.
Hi sir mera bhai he kaam aata he aapke pass aakar prectics karna h
Abhi to koi esa plan nahi hai big bro
Blue star inverter ac ki out door dc moter ka L3 error araha hai kiya karein
agar error dc motor se hai to motor change karo
@@electriclocha moter kitne ka hoga sir g
Thanks sir g dc moter kltne ki hogi
Sir agar wayar galat lag Jai to kya hoga
Please send me the motor testing kit but tell me the price
Can us Big bro 9213717087
12 hp outdoor fan motor required
Sir uvw क्या होता है
Bluestar vrv 22hp outdoor unit ki 750watt dc motor repairing ho sakti sir bata e aapka watsup no batae aapko photo bhej diga
خواهش میکنم ترجمه فارسی یا عربی بگذارید 🙏🙏🙏🙏
Sir is there anything to contact with u , ur mail
Hi Who are you
Big bro, My name is RAj Kumar
@@electriclocha
My name is Muhammad Saleem I live in Pakistan
Sir aap muj ko watssap nbr di
Nice video