Thanks for your information. If any technical support or after-sale services needed feel free to contact us at support@seplos.com Or any other suggestions, please contact us at info@seplos.com
Hi Onkel, could you please send an email to info@seplos.com. We'll check with the support team. And please assure that SEPLOS will take responsibility for any default caused by us.
I've checked with the support team, they mean that maybe something conducted falling into the BMS, and casued the short-circuit. And your sales representative has contacted with you about the replacement of the broken BMS. You can check the mailbox.
The external switched on bms, can you explain more on it, can connect a switch to it, if yes, what is is specifications, and also JST pin connector requirements
hello ,if i use a seplos bms on DIY lifepo4 16s on a deye inverter, what brand of battery i will need enter ? i can ajust sure the data like low , high current max etc on seplos software , but i think on deye need enter battery brand ! how to do ? , one of my friend tried use a seplos on SOLIS , but some parameters are not seen correctly , why noone do a BMS clone of a brands already pre setted in inverters on market ?
@Dala's EV Repair, we didn't test compatibility with Fronius inverters yet. But if you need, we can send you the CAN BUS protocol for comparison. If the protocol is the same, they're compatible. Or you can ask the Fronius for this CAN BUS protocol and send it to us. We will check it for you. We're available at info@seplos.com
Hello , i have the Seplos 200ah bms but it works not with growatt sph 4000. its connectet in growalt can but the growatt check and check the hole time but no connecting to the battery . only when i use agm / blei. i need some help
There might be some setup problems. Could you please send an email to support@seplos.com. The after-sale service will guide you to finish all the setup processes. Any other questions, please feel free to contact us at info@seplos.com
I have a sma sunny island 8.0 and I want to have a AC Coupled setup with some mitsubishi outlander batteries in 14s 58v. Would your bms be good for my setup?
Yes, our BMS preprogramed with SMA ptotocol, and it will work with your inverter. For the batteries, are you talking about NCM battery with the highest voltage of 4.2V*14s=58.8V?
@Joan Quintana Altimiras Thanks for your interest. We didn't test with SAJ H1 inverters that you mentioned. But the BMS supports CAN or RS485 communication. And it's preprogrammed with Goodwe/Pylontech/Growatt/sofar/Victron/luxpower protocol. And most inverters in the market apply the protocols. I have a suggestion to certify if you could send us the protocol of the SAJ inverter, and by comparison with our protocols, we can know if it is compatible.
Hi WoaznSigi, thanks for your comment. Our BMS could connect with the GoodWe GW3600S-BP inverter. For more details, please contact us at info@seplos.com
Hi Ritesh, thanks for your comments. You mean you need to buy a sample for testing? I will arrange a sales to contact you as soon as possible. Please check your mailbox. Any other problems or suggestions, please contact us at: info@seplos.com
Attention! Seplos does not send paid goods! Gap tel has been waiting for the paid bms for months. That despite paid shipping with FedEx. If seplos wants to be in 3 days with airmail at the customers. But Seplos doesn't seem to want
Do bms can work in series? Some hybrid inverters need higher voltage from battery fe 100V and more. ruclips.net/video/7nEwqEud_2c/видео.html In this video man connect the battery in series. Is it possible for seplos bms ?
I have been using this BMS for some projects,
It is very good
I will recommend
Thanks for your information.
If any technical support or after-sale services needed feel free to contact us at support@seplos.com
Or any other suggestions, please contact us at info@seplos.com
Great Solution from second Level Support .
I had a small problem, but the support solved it very well immediately. Thank you
Hi Onkel, could you please send an email to info@seplos.com. We'll check with the support team. And please assure that SEPLOS will take responsibility for any default caused by us.
I've checked with the support team, they mean that maybe something conducted falling into the BMS, and casued the short-circuit.
And your sales representative has contacted with you about the replacement of the broken BMS. You can check the mailbox.
Is this inverter compatible with StorEdge 3 phase systems?
The external switched on bms, can you explain more on it, can connect a switch to it, if yes, what is is specifications, and also JST pin connector requirements
I want to build a DIY battery with 16s EVE 280Ah about 15kw.Which semplos BMS should i order?
Mason 280 14.5kwh. You can know more by contacting our sales engineer at info@seplos.com
Is compatibly with MPPSolar PIP-5048 MGX inverter?
This BMS is compatible with the DEYE inverter as shown in the video?
Yes, this BMS is compatible with the DEYE inverters.
Can we used 16s bms in 8s configuration?
8S chips is different from 16S, so can not
Good video...those seplos BMS are compatible with Schneider inverters? thanks
hello ,if i use a seplos bms on DIY lifepo4 16s on a deye inverter, what brand of battery i will need enter ? i can ajust sure the data like low , high current max etc on seplos software , but i think on deye need enter battery brand ! how to do ? , one of my friend tried use a seplos on SOLIS , but some parameters are not seen correctly , why noone do a BMS clone of a brands already pre setted in inverters on market ?
will this bms support battery pack parallel and series like daisy chain?
@rahul chinnadurai
Support max. of 16 packs in parallel.
Can not in series.
Do you have a BMS that works with Fronius Symo inverters?
@Dala's EV Repair, we didn't test compatibility with Fronius inverters yet.
But if you need, we can send you the CAN BUS protocol for comparison. If the protocol is the same, they're compatible.
Or you can ask the Fronius for this CAN BUS protocol and send it to us. We will check it for you.
We're available at info@seplos.com
Does it have Bluetooth access option via a mobile app for management?
@Seun Ojedeji Thanks for your inquiry. Our BMS has computer software only at present.
very interesting BMS :-) , where can i download that batteriemonitor software, manuals and protokolls ,(i am interesting on Seplos 16s 200A Version)?
16s 200A version is available. Please contact us at info@seplos.com
@@SeplosTechnology I buy it :-) , very good documentation!
Hello , i have the Seplos 200ah bms but it works not with growatt sph 4000. its connectet in growalt can but the growatt check and check the hole time but no connecting to the battery . only when i use agm / blei.
i need some help
There might be some setup problems. Could you please send an email to support@seplos.com. The after-sale service will guide you to finish all the setup processes. Any other questions, please feel free to contact us at info@seplos.com
Can u send video with luxpower lxp-5k that can be compatible in CAN BUS?
We have pre-programmed LUXPOWER protocol to the BMS. Just choose LUXPOWER CAN protocol. The system will compatible with your inverter.
I have a sma sunny island 8.0 and I want to have a AC Coupled setup with some mitsubishi outlander batteries in 14s 58v.
Would your bms be good for my setup?
Yes, our BMS preprogramed with SMA ptotocol, and it will work with your inverter.
For the batteries, are you talking about NCM battery with the highest voltage of 4.2V*14s=58.8V?
@@SeplosTechnology
Yes, thanks for your reply.
I've been in contact with Chris and have ordered one. I can't wait to try it.
@@martdaymo Does it work with outlander battery? Did you make some test with bms and the battery?
@@johnydeep1094 I haven't receive the bms as yet, I only order it last week.
Will test when it arrives..
@@martdaymo Thank you for the answer! If it arrive, lets me know how works bms with battery.
Thus this bms is compatible at Luxpower inverter???
We have Luxpower protocol, so it is ok
@@sotoshinakamotor7087 i need 17s 200amp how much and pls show a video that it is working in lux power lxp 5kw?
Curious if you guys sell a dev kit, or samples? Very curious about this unit
It is ok
Does the 16s 200a SEPLOS BMS work with Victron Energy?
yes. Check the link below.
www.seplos.com/cases/seplos-pusung-r-pusung-s-suten-w-home-energy-storage-battey-pack-compatibility-3802.html
@@SeplosTechnology how to do CAN communicate with victron?
Hello
I'm very interested
This Model is compatible with SAJ H1 6K-S2?
@Joan Quintana Altimiras Thanks for your interest.
We didn't test with SAJ H1 inverters that you mentioned.
But the BMS supports CAN or RS485 communication. And it's preprogrammed with Goodwe/Pylontech/Growatt/sofar/Victron/luxpower protocol. And most inverters in the market apply the protocols.
I have a suggestion to certify if you could send us the protocol of the SAJ inverter, and by comparison with our protocols, we can know if it is compatible.
Can you connect to goodwe GW3600S-BP?
Hi WoaznSigi, thanks for your comment.
Our BMS could connect with the GoodWe GW3600S-BP inverter.
For more details, please contact us at info@seplos.com
I would like to buy this BMS. Is it compatible to GoodWe inverters (ES or EM series)?
Yes, it will compatible with Goodwe inverters.
what is the lugs size?
You mean the wire from BMS to BATTERY? 750mm
i wont to get this bms soon for our off grid system soon ray on you tube sow abot this
Where do I download the battery monitoring software?
Here with this link, you can download the BatteryMonitor software: drive.google.com/drive/folders/10pxgNLHovcDZRVGrCZsSkfecBrRw-AdW?usp=sharing
What i need to do for your bms testing
Call me at 7007013414
Send me details for this email add: iamritesh2017@gmail.com
Hi Ritesh, thanks for your comments.
You mean you need to buy a sample for testing?
I will arrange a sales to contact you as soon as possible. Please check your mailbox. Any other problems or suggestions, please contact us at: info@seplos.com
Lithium-ion setting? 4.2v
We have the NCM type
@@sotoshinakamotor7087 i need to talk to someone in sales
@@roqm1248 allen@seplos.com
Attention! Seplos does not send paid goods! Gap tel has been waiting for the paid bms for months. That despite paid shipping with FedEx. If seplos wants to be in 3 days with airmail at the customers. But Seplos doesn't seem to want
Do bms can work in series? Some hybrid inverters need higher voltage from battery fe 100V and more. ruclips.net/video/7nEwqEud_2c/видео.html In this video man connect the battery in series. Is it possible for seplos bms ?
Pylontech battery pack comes with a battery management unit. The battery packs are connected in parallel to increase capacity.
very interesting BMS :-) , where can i download that batteriemonitor software, manuals and protokolls ,(i am interesting on Seplos 16s 150A Version)?
Please contact us at info@seplos.com