Curtailment of Bars in Beam

Поделиться
HTML-код
  • Опубликовано: 16 ноя 2018
  • This video shows how to curtail reinforcement in beams. It shows that you have not to curtail reinforcement in critical sections where you have maximum bending moment, you are not allowed to curtail bars in that region. The curtailment we do in beams or in slab because to make economical design, where we need no reinforcement to resist bending moment, so we place no steel bar over there.
    Our channel brings civil engineering videos for students of Diploma, B-tech, M-tech, Bachelors and Masters.
    Subscribe our channel for more civil engineering videos.

Комментарии • 66

  • @ChhotanKuamar-fe8tb
    @ChhotanKuamar-fe8tb 2 месяца назад +1

    Aapka Har video 100 me se 90 present smjh aata hai Thank you sir civil guru jee ki jay ho

  • @hashtagvizag
    @hashtagvizag Год назад +4

    L/3 and L/8 : L is length of column centre to column centre and not column inner to column inner...correct it!!!

  • @sudiaujwal
    @sudiaujwal 3 года назад +4

    How decide l/3 and l/8 for extra bars

  • @noushadkhan5294
    @noushadkhan5294 4 года назад +1

    Thank u to share very imprtnt knowledge with us👍.

  • @hammadkhattak3290
    @hammadkhattak3290 3 года назад

    you explained it really simple bro...God bless you

  • @nareshchandrasarkar1550
    @nareshchandrasarkar1550 4 года назад

    Than when we use crank bar? Is same arrangements crank and curtailment bar? Can I replace curtailment to crank bar?

  • @manu88home
    @manu88home 5 лет назад

    Really nice today is my exam it helped a lot

  • @kalashramteke5445
    @kalashramteke5445 4 года назад

    Thank you sir...nice explaination

  • @srikeshrai6579
    @srikeshrai6579 5 месяцев назад +1

    Good
    ,I am foreman of steel.

  • @munnanimbal6024
    @munnanimbal6024 4 года назад

    Thank you 🙏

  • @atiquehussain8716
    @atiquehussain8716 4 года назад +1

    Thank you very much brother for sharing your knowledge. Really appreciated.

  • @Ash-tp3im
    @Ash-tp3im 4 года назад

    Curtaiment same Hoti h kya slab ki bhi

  • @mubarakhossain4360
    @mubarakhossain4360 2 года назад

    It was very helpfull thank you brother

  • @engrmdanwarhossainjahangir9985
    @engrmdanwarhossainjahangir9985 3 года назад

    Thanks for good explain.

  • @aftabmirza43
    @aftabmirza43 2 года назад +1

    Sir if l/4 =0.25l ,l/2= 0.5l what is value of 0.15l and 0.3l ?? so I want list of all these values in which code or book I will get all these values plz tell me sir

  • @yashawantgaikwad9070
    @yashawantgaikwad9070 2 года назад

    Nice job sir.

  • @ratanhemram3475
    @ratanhemram3475 3 года назад

    super video aur chahie

  • @BuildingWorker11
    @BuildingWorker11 2 года назад

    Thanks for information

  • @nitishdhiman6333
    @nitishdhiman6333 2 года назад

    Some beams bottom use l/4 in the beam can u explain where we can use the l/4 or l/8 concept

    • @wtfplays333
      @wtfplays333 3 месяца назад

      Continuous beam L/3
      End beam L/4

  • @Ermohdsuhaib
    @Ermohdsuhaib Год назад +1

    Column ko add nhi kya apne

  • @RoshanKumar-vd6ni
    @RoshanKumar-vd6ni 3 года назад +1

    Thank you Sir...

  • @satyavirnolia4884
    @satyavirnolia4884 Год назад

    Sir , top extra bar at the end col will be in the shape of L ie ( Ld + length of top extra bar from outer face of col ) Please clarify the matter.

    • @MAnas-el6cd
      @MAnas-el6cd 11 месяцев назад

      Yes you are right development length / Anchorage length must be provided

  • @girishrane4641
    @girishrane4641 5 лет назад

    How to tie stirrups in the middle if bar not provided?

  • @ManojPrajapati-kf7ds
    @ManojPrajapati-kf7ds 3 года назад

    Osame yar

  • @amitchavan5364
    @amitchavan5364 Год назад

    Continuous nd discontinues side pe same ata hai kya sir

    • @MAnas-el6cd
      @MAnas-el6cd 11 месяцев назад

      For top extra
      L/4 is used at dis continues side and L/3 at continues side usually

  • @shivakumardadgi8142
    @shivakumardadgi8142 3 года назад

    For continuous beam how

  • @abdurrahim3605
    @abdurrahim3605 9 месяцев назад

    Thanks

  • @jazzroyal865
    @jazzroyal865 2 года назад

    Sir one que. Jo. Apne l/3. =13.1 aa gya. Fr column me. Uska L and kitna column k adr rkhna he j to btao na g
    .

    • @LivingOnTheEdge123
      @LivingOnTheEdge123 2 года назад +1

      Column ka under toh . Dusra main bars ki tarah same development lenghth hoga

    • @jazzroyal865
      @jazzroyal865 9 месяцев назад

      ​​​@@LivingOnTheEdge123 develpment lenth l/4 +column +develment length RIGHT NA ?? SIR IS CODE K ACCORDING TO DEVELMENT LENTH BHUT BADI HO JATI HAI kya kre g

  • @tarun_nehra90
    @tarun_nehra90 4 года назад +1

    These are extra bars not main bars.
    Curtailment done only on end extra and bottom extra bars

  • @premnandwana7671
    @premnandwana7671 Год назад

    IS कोड क्या क् ह्ता या क्योकि कुछ टॉप बीम मे टॉप बार L/4 तक व बॉटम बार L/6 लेते हे जबकि कुछ लोग L/3 व L/8 lete हे क्या स हि हे

  • @ShyamSingh-yg2gq
    @ShyamSingh-yg2gq 3 года назад

    Good

  • @dhiresh68
    @dhiresh68 Год назад

    Sir why we use curtailment of bars

  • @Samuelwengebanda
    @Samuelwengebanda 5 лет назад +2

    Subject is in English but the procedure is being explained in a different language

  • @mdwalidkhan7768
    @mdwalidkhan7768 5 месяцев назад +1

    ❤❤❤❤❤

  • @rajagyadi9856
    @rajagyadi9856 4 года назад

    👍👍👍👍

  • @pdcetview
    @pdcetview 3 года назад

    L should be effective length

  • @kundansanap1042
    @kundansanap1042 3 года назад

    R u from Pakistan?

  • @AB-kc2ms
    @AB-kc2ms 2 года назад

    English subtitles plz

  • @spainborlangchyne9020
    @spainborlangchyne9020 2 года назад

    Waw how L/3?

  • @lionelchia7211
    @lionelchia7211 5 лет назад

    If both your title and language are in english, you should also be explaining the subject in english in your video.

  • @engineermwaleedjan250
    @engineermwaleedjan250 Год назад

    kindly dont provide extra bar at bottom bcz it can collapse bcz of no ductility in bending moment

    • @MAnas-el6cd
      @MAnas-el6cd 11 месяцев назад

      No brother i don't agree with u Becoz bottom extra is provided at bottom centre to resist bending.
      And is provided in most cases especially in main beams

  • @amitchavan5364
    @amitchavan5364 Год назад

    .15 L pe curtail

  • @rameshgiri7412
    @rameshgiri7412 3 года назад

    Seen so many engrs channel but felt very disappointed

  • @rajacharya122
    @rajacharya122 10 месяцев назад

    Video not clear