sir,am getting F2 Error new outdoor pcb installed Vectra plantina 1.5Ton original pcb microprocessor damaged, compressor runs 5min then shuts outdoor Cooling fan not running pcb led blinks 5 times and loops when compressor running cooling is there for only 5 min. then only blower runs for 30 min and displays F2 what to do sir?
2 months old voltas 2 ton ac me pcb change karne baad bhi problem aarahi hai ac switch off krke 1 minute baad onn karne me sahi hojata hai koi solution hai...
Jahir bhai, mera 1 minute ke liye aata hai yeh issue, phir theek ho jaata hai. Shaayad voltage problem hogi na? Technician ko bulaunga toh woh toh bolega hi pcb change kro
My voltas Vectra plantina 1.5 ton Ac is just 10 days old and it suddenly shows f2 in today afternoon then i restart my Ac , it works as normal and also give cooling so bhai can you say that what is fault in my ac
Jahir bhai..mera F2 aaya tha.. PCB change Kiya.. Fir 2 din bad fir s Compressor chalna band ho gya.. Aur F2 Error show hone lga. Ye bar bar Aisa kyu ho rha h
Thanks, F2 ka matlab compressor divice ka problem, out door pcb kai ander hota hay, pcb ka problem ak voltage kai liya hota hay dusra wear alter net ki bajai sai vi hota hay
@@jahirtechnical pipe extra nhi lga h jahir bhai. जितना मिलता है, उतने में ही काम हो गया था। अब ये बताइए ऐसा दिक्कत kyu aa रहा है। नया PCB भी लगवा दिए, पर 2 दिन बाद ही F2 आने लगा।
Apka electric stabiliger laga huya hai? Apka voltage problem hay to nahi, app indoor or out door wearing check karo main wear L-L/N-N/3-3 seme wear laga huya kai nahi dako , alter net hoga to v problem ho sakta hai
sir,am getting F2 Error new outdoor pcb installed Vectra plantina 1.5Ton original pcb microprocessor damaged, compressor runs 5min then shuts outdoor Cooling fan not running pcb led blinks 5 times and loops when compressor running cooling is there for only 5 min. then only blower runs for 30 min and displays F2 what to do sir?
2 months old voltas 2 ton ac me pcb change karne baad bhi problem aarahi hai ac switch off krke 1 minute baad onn karne me sahi hojata hai koi solution hai...
Problem kai hai
@@jahirtechnical problem ye ki f2 error aarha hai pcb bhi change ho chuki aur indoor bhi check karwa chuka
@@jahirtechnical kese sahi hoga yaar
Jahir bhai, mera 1 minute ke liye aata hai yeh issue, phir theek ho jaata hai. Shaayad voltage problem hogi na? Technician ko bulaunga toh woh toh bolega hi pcb change kro
1 saal puraana split ac h sirf
Jab tak chal raha hai aysai chalna do
@@jahirtechnical toh kharab warab toh ni hoga? usually jb 240V se jyada hota h, tabhi yeh problem aati h
Stabilizer hai
@@jahirtechnical yes, wohi toh input reading show kr rha h. stabilizer ki range 220-270 hai, pr 240 se upar jaate hi blink hone lgta h
Bhai mera 1.5ton Voltas ac 1yr old h but aaj chlte chlte F2 error aa rha h cooling ni kr rha only indoor chla rha out door bnd kya poblm h bhai pls
Same problem meri mee bhi hai complain Kiya hai .
My voltas Vectra plantina 1.5 ton Ac is just 10 days old and it suddenly shows f2 in today afternoon then i restart my Ac , it works as normal and also give cooling so bhai can you say that what is fault in my ac
Lo volts hondf
@@jahirtechnical So you mean low voltage but bhai I have also installed stabilizer
Mera abhi ho rha h Bhai apka kya hua fir btao plz
@@Shotgun10000don't worry brother..... Aap ke area me low voltage ke liye AISA ho Raha hee
@@pritammohapatra2598 but I using heavy stabilizer
Matlab sensors ok hoga to pcb problem
Ja
F2 aa rha hai mere mai bhi
70℅ pcb problem, chack karnay ka bade pata chalega
Sr F2 ane ke pr ac chalaane chaehe
👍👍👍👍👍👍
Voltas ki ac bahut beka atin hai kabhi lena
Kuch loge asiko feber karta hai
12 kaun sa error hai
Konsa machine
12 eror nhi lock code h
Installation code
PC Badal Diya
Ha
Jahir bhai..mera F2 aaya tha..
PCB change Kiya..
Fir 2 din bad fir s Compressor chalna band ho gya..
Aur F2 Error show hone lga.
Ye bar bar Aisa kyu ho rha h
Thanks, F2 ka matlab compressor divice ka problem, out door pcb kai ander hota hay, pcb ka problem ak voltage kai liya hota hay dusra wear alter net ki bajai sai vi hota hay
Paip line kitna exter huya hai ya nahi
@@jahirtechnical pipe extra nhi lga h jahir bhai.
जितना मिलता है, उतने में ही काम हो गया था।
अब ये बताइए ऐसा दिक्कत kyu aa रहा है।
नया PCB भी लगवा दिए, पर 2 दिन बाद ही F2 आने लगा।
Apka electric stabiliger laga huya hai? Apka voltage problem hay to nahi, app indoor or out door wearing check karo main wear L-L/N-N/3-3 seme wear laga huya kai nahi dako , alter net hoga to v problem ho sakta hai