OMRON PLC SCL (DATA SCALING),ANALOG INPUT PROGRAMMING IN OMRON PLC
HTML-код
- Опубликовано: 9 фев 2025
- OMRON PLC SCL (DATA SCALING)
ANALOG INPUT PROGRAMMING IN OMRON PLC
ANALOGIN INPUT WORKING IN OMRON PLC
SCALING INSTRUCTION IN OMRON PLC
0-10vdc INPUT IN VOLTAGE
tempareatur 25c to 300c
p1 minimum of result value 25c
p1+1 minimum of source value 00
p1+2 maximum of result value 300c
p1+3 maximum of source value 1770 hex
analog input voltage source(hex) result(bcd)
0 0 25c
5v bb8 163c
10v 1770 300c Наука
GOOD. SCL2 SCL3 USED FOR
sir Good
Sir ( PULS & SPED ) SERVO DRIVE KA LOGIN PE BNAO VIDEO PLEASE
Sir aek vidio analog output pr bnavo
Sir DIFU ka working kya hai
www.google.com/url?sa=t&source=web&rct=j&url=m.youtube.com/watch%3Fv%3D88ddSuVXvLc&ved=2ahUKEwjho9e0vJH6AhWWTGwGHddPBE4Qz40FegQIBBAI&sqi=2&usg=AOvVaw2tBx3S5E0FE9Yh4_USZSHe