My brother the in sha Allah my Allah will give you rewards for this I will always remember you in my prayers and my mother will also special prayers for you.the job which you done and doing it's not rear it's very big job.
Checking high volt firtpoper checking 2nd low vlot checking trasformevlow 24 vlot checking rc ry1 r2stage checking g blower Rc 24v y1 y2 stage 1st y22nd stage out hp lp checking thefmost displying showing no point trssing one ponited ...
Bhai ne ayesa samjaya hai aankh band kar ke problem solve kar sakte hai Bhai phase previnter ke bare me explain karte to sekhne me aur maja aa ja pls video ko like kare aur chennal ko subscribe kare❤❤❤❤❤ se like karo
bhai is playlist main poora ka poora topic cover kiya gaya hai . ummed karta hoon aapke sawal ka jawab insha Allah jarror mil jayega . please follow link👉ruclips.net/p/PLJq2nNUZcqZNVOguI2x9scejI8IRr2XqW
Bro aap ne jo bataya h ye (C) ke bare me c to comsn h na agr man lo kisi thermostat me betteri rhta us me 24v chek krna h to c ki jgh bodi ko us krna pdega
nahi bro same tarika yahi rahega kyonki ham package ac ke remote wale tarminal par 24 volt check kar rahe hain na ki remote par . remote wale tarminal par (R,C) 24 volt hamesha milega agar ac main supply aa rahi hai..
same unit hai ? . contectar on hai ya off jab fan band hota hai . agar contectar on hai aur fan off hai to motar ka problem ho sakta hai . aur contectar off hota hai to remote ya wiring / safety device check kar low .. full detail den to main full guide kar doonga 🤝
Boss same yei hi unit Hai carrier ka contactor press krain tu energize ho jata Hai khud se compressor on ni hota jb k blower motor or condenser motor work krti hain kindly is ka kch btaye
contactor aur relay ( black wali / lockout rilay ) dono ko check kar len ki sahi hai chahen to direct 24 volt dekar check kar len ya multimeter se reading se bhi check kar sakte hain aap ye wali video dekh len ismen maine bataya huwa hai 👉. ruclips.net/video/GruxknWa1iM/видео.html
Contacter good no checking in out power one ponit checking contacter 3pole point checkinv metar contvety checking after out normal checking one by any fult have no conforme resom systom ruing condshion need phcicl checking terminal ppoint checking after testing ok power testing totaly after checking testing tresing ok ameper checking gas low low ok chargeing amper checking gas gas checking gasusing uinit checking expleaz R22 ok R410ok checking stadrd checking nsme plat checking techshion checkinv solveing all mattrs point ok sif jolly .
lockout relay se karna hai 2 , 3 ko short karna hai jitni der on rakhna hai utni der short karna padega black waali relay se karna hai to 2, 4 ko short rakhenge
@@thetechhvac bhai agr really se shor karane per bhi nh start hota hai to kya problem ho sakti hai Our remote se out door Tak y1 our y2 me 34 bolt aarha hai bhai lekin relay me 24 nh aarha hai plz reply
HP LP agar problem karega to bhi relay par volt nahi aayenge ( lekin relay se short karane par bhi on nahi ho raha hai to phir contactor ka bhi problem ho sakta hai kyonki jaise hi ham 2 ,4 no ko aapas main short karenge waise hi sab kuchh bypass ho jayega isliye …) full detail de to main aapko poori tarah se guide kar paoonga ki kitne tin ka ac hai kis company ka etc…
@@thetechhvac bhai esa krne per trip hojarhi hai masin white bala bahar aajarha hai 1 nmbr compressior chalrha hai 2 nmbr me problem aarha hai bhai contactor push krne per jher jher krke contactor phir masin trip horhi hai plz reply?
aap relay se short karke dekho (black wali relay se ) agar phir bhi hota hai to contactor chek karlo , contactor aur relay main se koi ek problem kar raha hoga
I have the same device, I encountered a problem when I run it. I have the compressor directly without the blower working first, then the compressor with the fans,,, what is the cause of the problem?
Bhai agar contractor ac on hone ke baad baar baar on off ho raha h to kya problem h contractor ekdum se on hota h phir off yani 24 volt aarah h aur ja raha h baar baar problem samajh nahi aayi
maine is video main wiring se related detail main bataya huwa hai aap is video ko dekh sakte hain . chahen to aap poori video dekh len nahi to aap skip kar sakte hain 👉ruclips.net/video/TXDxVakijnE/видео.html
doston please channel ko subscribe jaroor kar len.👉🔔🙏❤💥
Wonderful explain for control circuit system
Kabele tarif bhaijaan jitna tarif kre utna Kam h 👍👍👍👍👍
Very nice education bhai
Bahut achhi jankarib diye bhai bahut bahut sukriya Dil SE bhai.
🎉❤
Boss Allah Pak aapko hamesha salamat rakhe❤❤❤❤❤
👍 thanks bhai...
Excellent performance Bhai
Mene pehli bar dekhe hai kisi ko itna mst explain krte huwa h ❤❤
it’s my pleasure 🤝💚
Good explain bhai ji
🤝💚
Good information
Thanks..
it's my pleasure 💚
My brother the in sha Allah my Allah will give you rewards for this I will always remember you in my prayers and my mother will also special prayers for you.the job which you done and doing it's not rear it's very big job.
aap logon ki duwa hi mera reward hai..🤲💚🤝
Checking high volt firtpoper checking 2nd low vlot checking trasformevlow 24 vlot checking rc ry1 r2stage checking g blower Rc 24v y1 y2 stage 1st y22nd stage out hp lp checking thefmost displying showing no point trssing one ponited ...
Main pont bord checking afte poper checking resy stger is checking hp lp power voltchecking
Metshowinv ok no reding damges
Yes absolutely this is wonderful ❤❤❤❤ god bless you
Good information brother always Helpful
Veri good information
Thanks 😍
Good explain sir ji
Thanks and welcome ❤️
Excellent Brother 👍
Thanks for the visit 💚 🤝
Bahut ACHA see bataye h Bhai
Good information bro
Good luck ❤❤❤
Wow very nice video bro
Good job sir G aap ne Jo detail se Bata ya hia Asa koi nahi Bata ye ga
Yes you are right
Very youse full information thankyou bhai reley ka cnaction seferet vedio banao
done
Bhai aapka number chahie Mujhe
Shukriya bhai sahab aapka video Dekhkar mujhe bahut Achcha Laga
Main aapse baat karna chahta hun mere bhai
Super
Very experience bhay ❤
You're great❤
I have learning so many things AC related to you those I didn’t know before, take salam to me,may Allah bless you and your family.
jazakallah 💚 🤲
Bahut achchi video banai h bro ❤
Yes
🎉
Bhai ne ayesa samjaya hai aankh band kar ke problem solve kar sakte hai Bhai phase previnter ke bare me explain karte to sekhne me aur maja aa ja pls video ko like kare aur chennal ko subscribe kare❤❤❤❤❤ se like karo
bhai is playlist main poora ka poora topic cover kiya gaya hai . ummed karta hoon aapke sawal ka jawab insha Allah jarror mil jayega . please follow link👉ruclips.net/p/PLJq2nNUZcqZNVOguI2x9scejI8IRr2XqW
Good information bro thanxs ❤
❤❤❤
Dakina AC 10 tan ke video bano Bahi Kase tam❤
A very thorough explanation, but does it have an English translation because I don't speak Urdu?
Bhai old carrier package dx unit ka diagram batao na bhai plzzz....
Thank you bro good explain
You are welcome 🤝
Thank you
You're welcome
Bhai lockout realy par thoda ache se video banao bhai
ok brother
Bhai ek aur cheg TRANE ka package hai jo ki model TCH150C300CA Hai iske wiring par bhi video banao
ok
@@nicerefrigeration
Bhi kabhi ap ne carrier me 2 timer ata hai uske bare me nahi bataya please uske bare me bhi bataya karo
bhai timer uske sath lag karke nahi aata hai is wajah se . baki main koshish karoonga ✅
@@thetechhvac tnx Bhai
Bro aap ne jo bataya h ye (C) ke bare me c to comsn h na
agr man lo kisi thermostat me betteri rhta us me 24v chek krna h to c ki jgh bodi ko us krna pdega
nahi bro same tarika yahi rahega kyonki ham package ac ke remote wale tarminal par 24 volt check kar rahe hain na ki remote par . remote wale tarminal par (R,C) 24 volt hamesha milega agar ac main supply aa rahi hai..
@@thetechhvac bhai aap ke whatsapp number mil skta h kya
25 Ton package ka unit kithna amp liyega
Bro fan moter 5 min chal k band ho jati hain dono kia problm hogi
same unit hai ? .
contectar on hai ya off jab fan band hota hai . agar contectar on hai aur fan off hai to motar ka problem ho sakta hai . aur contectar off hota hai to remote ya wiring / safety device check kar low ..
full detail den to main full guide kar doonga 🤝
Boss same yei hi unit Hai carrier ka contactor press krain tu energize ho jata Hai khud se compressor on ni hota jb k blower motor or condenser motor work krti hain kindly is ka kch btaye
contactor aur relay ( black wali / lockout rilay ) dono ko check kar len ki sahi hai chahen to direct 24 volt dekar check kar len ya multimeter se reading se bhi check kar sakte hain
aap ye wali video dekh len ismen maine bataya huwa hai 👉. ruclips.net/video/GruxknWa1iM/видео.html
Contacter good no checking in out power one ponit checking contacter 3pole point checkinv metar contvety checking after out normal checking one by any fult have no conforme resom systom ruing condshion need phcicl checking terminal ppoint checking after testing ok power testing totaly after checking testing tresing ok ameper checking gas low low ok chargeing amper checking gas gas checking gasusing uinit checking expleaz R22 ok R410ok checking stadrd checking nsme plat checking techshion checkinv solveing all mattrs point ok sif jolly .
Compressor ke bare me pucha hai bhai kaise sort kra ke start krna 2 .3 thora sort krna hai ya join krdena hai dono ko phir masin on krna hai reply
lockout relay se karna hai 2 , 3 ko short karna hai jitni der on rakhna hai utni der short karna padega
black waali relay se karna hai to 2, 4 ko short rakhenge
@@thetechhvac bhai agr really se shor karane per bhi nh start hota hai to kya problem ho sakti hai
Our remote se out door Tak y1 our y2 me 34 bolt aarha hai bhai lekin relay me 24 nh aarha hai plz reply
HP LP agar problem karega to bhi relay par volt nahi aayenge ( lekin relay se short karane par bhi on nahi ho raha hai to phir contactor ka bhi problem ho sakta hai kyonki jaise hi ham 2 ,4 no ko aapas main short karenge waise hi sab kuchh bypass ho jayega isliye …) full detail de to main aapko poori tarah se guide kar paoonga ki kitne tin ka ac hai kis company ka etc…
@@thetechhvac hp lp khrab hai ye kaise malum krenge bhai
Bhai sort kaise karana hai 2 our 3 ko joint krdena hai ya phir bus thora sour krna hai plz fast reply
jitni der on rakhna hai utni der
@@thetechhvac bhai esa krne per trip hojarhi hai masin white bala bahar aajarha hai 1 nmbr compressior chalrha hai 2 nmbr me problem aarha hai bhai contactor push krne per jher jher krke contactor phir masin trip horhi hai plz reply?
aap relay se short karke dekho (black wali relay se ) agar phir bhi hota hai to contactor chek karlo , contactor aur relay main se koi ek problem kar raha hoga
@@thetechhvac bhai really se konsi konsi wire short karani hai reply career ka unit hai bhai
2 aur 4
I have the same device, I encountered a problem when I run it. I have the compressor directly without the blower working first, then the compressor with the fans,,, what is the cause of the problem?
I may have replied to you on whatsApp
Bhai agar contractor ac on hone ke baad baar baar on off ho raha h to kya problem h contractor ekdum se on hota h phir off yani 24 volt aarah h aur ja raha h baar baar problem samajh nahi aayi
ye video dekh len serial wise bataya gaya hai . 👉.ruclips.net/video/GruxknWa1iM/видео.html
Tm log market Karab karta hooo
koi defination hai ki kaise market kharab hoti . ya fir 🔥
Bhai blower motor ka relay pe thoda confusion hai
maine is video main wiring se related detail main bataya huwa hai aap is video ko dekh sakte hain . chahen to aap poori video dekh len nahi to aap skip kar sakte hain 👉ruclips.net/video/TXDxVakijnE/видео.html
❤❤❤❤❤❤❤