155 LRA compresure single phase compresue start hota h high amp leke trip ho jata h.compresure heat v hota h.compresure ko cold karne k baad on nhi hota compresue new compresue h gas sb thik h.new capacitor dala h 55 mfd ka.
Bhai jo contector का A1aur A2 hota waha pe likha hota nahi to jo contector ka ditels diya hota hai waha pe likha hota hai okay bhai contector coil 24 volt ka hai या 230 volt ka hai
Aapka ac ka probalm hai compressor cut off nahi ho rha hai ok bhai aapka package unit BMS se canection hai to aap returns air sensor ko check kare augr tharmostat se hai to tharmostat me temperature ko badha ke check kare phir bhi nahi thik hota hai to tharmostat ko chenge kare okay bhai
Very good video 👌👌👌👌👌👌👍👍👍👍👍👍👍👍🙏🙏🙏🙏
Thanks bhai
Good video sir
Very good video
Thanks
Nice brother
Thanks
Nice
Thanks brother
❤ Always helpful brother everyday esa practical video upload kare brother ❤😮
Okay brother and thanku so much
Excellent
Thank you! Cheers!
goood ❤
Thanks
Nice video
Thanks
This video for new technician
155 LRA compresure single phase compresue start hota h high amp leke trip ho jata h.compresure heat v hota h.compresure ko cold karne k baad on nhi hota compresue new compresue h gas sb thik h.new capacitor dala h 55 mfd ka.
LRA 155 ka single phese ka compressor hota hai keya bhai
Bhai kis point per check karteh hai ki compressor ke contacts per 24volt hai ki nai. Check KAHA karteh hai
Bhai jo contector का A1aur A2 hota waha pe likha hota nahi to jo contector ka ditels diya hota hai waha pe likha hota hai okay bhai contector coil 24 volt ka hai या 230 volt ka hai
Bhai Jo contactor ke niche me LGA hai wo kya hai Usme kaise setting Hoti hai please reply bhai
Bhai o over lode hai
Sir aapki company mein job milega ac technician ki full nolej hai🙏🙏🙏🙏🙏❤️
Ha bhai abhi kaha pe ho
Zamil pacu k both compressoe ddc ma trip ho jaty hyn compressor run ni hyn.but pcb ma koi alarm ni ha. Kia waja ho sakti ha
Aapka Matlab hai aapke BMS ddc me trip hota hai bataye pahle ok bhai
@@mktechnicalsolutions ddc ma alaram hota ha but pcb ma koi indication ni hoti
Bhai saab blower run ho rahaa hai lekin compressor temprature me cut off nahi ho rahata hai...
OK bhai aapka package ac room temperature mention kar rha hai ki nahi
Aapka ac ka probalm hai compressor cut off nahi ho rha hai ok bhai aapka package unit BMS se canection hai to aap returns air sensor ko check kare augr tharmostat se hai to tharmostat me temperature ko badha ke check kare phir bhi nahi thik hota hai to tharmostat ko chenge kare okay bhai
Aur aapka ac room temperature mention nahi kar payega to bhi cut off nahi milega okay bhai