Column size and sariya details for 1 storey,2 storeys,3 storeys, 4 storeys & 5 storey house

Поделиться
HTML-код
  • Опубликовано: 30 сен 2024
  • Disclaimer - This video is for educational purposes only. Copyright Disclaimer under section 107 of the copyright act 1976, allowance is made for "fair use" for purposes such as criticism, comment, news reporting, teaching, scholarship and research. Fair use is a use permitted by copyright statutes that might otherwise be infringing. Non-profit educational or personal use tips the balance in favour of fair use.
    Column size and sariya details for 1 storey,2 storeys,3 storeys, 4 storeys & 5 storey house
    In this video we know about column size and sariya details for Single storey building, double Storey building, 3 storey building, 4 Storey building & 5 storey floor building and also know about what is minimum and maximum distance between two-column. Ek manjila Makan, do manjila Makan, 3 मंजिला मकान और 4 मंजिला मकान के लिए कॉलम का साइज और सरिया क्या होना चाहिए. column size for G+0, G+1,G+2,G+3 Building construction.
    #RCCColumnStandardSize #ColumnReinforcement #ColumnHeight
    Topic Covered:-
    Columns sizes for various floors
    Column size and sariya details for 1 storey,2 storeys,3 storeys, 4 storeys & 5 storey house,
    building design
    various column sizes
    what is the column size for the g+1 building
    minimum column design
    g+1 building design
    column design
    minimum size of column
    column size for ground story building
    different column sizes
    apartment building column sizes
    building design by staad pro
    column size for 1 storey building
    column size for 2 storey building
    column size for 3 storey building
    column size for 4 storey building
    column size for g+0 building construction
    column size for g+1 building
    column size for g+2 building
    column size for g+3 building
    RCC Column Standard Size
    RCC column standard size
    the standard size of the column
    standard column size residential building
    RCC column size calculation
    Bar Bending Schedule Basics: Especially for Freshers Civil Engineers (Bar Bending Schedule Part-1) Kindle Edition
    amzn.to/3uvEMNo
    My Social Media Link:-
    Telegram Link:-
    t.me/yoursengi...
    Facebook page:-
    / yoursengineer
    Facebook group:- / yoursengineer
    Twitter link:- / yoursengineer
    Instagram link:- / yoursengineer
    Pinterest:- / _created
    Linkedin:- / vishal-goel-17426a48
    Website:- myengineeringsupport.com
    Accessories I Use for making Videos
    Mic I use - amzn.to/3r5f1S6
    The laptop I use - amzn.to/3ayYNu3
    Laptop Stand I Use- amzn.to/3cnILpj
    _______________________________________________________
    LIKE | SHARE | SUBSCRIBE FOR MORE VIDEOS LIKE THIS
    ~
    THANKS FOR WATCHING! -ENJOY
    ===============================

Комментарии • 312

  • @RajendraRajRp
    @RajendraRajRp Год назад +2

    Sir ham 1,2,3 Manjila makan ke liye faundesan khudai+ jali L size kitna rakhna hai,khudai kitna karwaye, abhi2 manjila de rahe hai please bataiye sir

  • @aebyscreationsfunlatest1456
    @aebyscreationsfunlatest1456 Год назад +7

    Thankyou so much sir, bahut videos dekha par doubt clear nahi ho raha tha , par aapne sare doubts clear kar diye .. very informative video 😊🙏👏👏🤗🙏

  • @soumyadas2395
    @soumyadas2395 7 месяцев назад +1

    Sir humhara 2 manjil hai column 10×10 hai aur usme 4 sariya 12 mm ki hai aur usme stripes 6/5.5 mm ki hai to sir es se koyi problem hoga kya?

  • @lingarajswain3086
    @lingarajswain3086 14 дней назад

    For G+1 , column distance 4m . Column size 9*12 ,steel used 16mm 4pc and 12mm 2pc , is it safe?

  • @devbhatt1000
    @devbhatt1000 Год назад +1

    Sir 9×9 inch column mai kya G+2 ya 3 manjil makaan bana sakte hai??

  • @sagarverma08
    @sagarverma08 3 месяца назад

    After g+2, I used 4 steel-16 mm dia and 2 steel -12 mm dia in my column, I have constructed G +4, is there any problem.

  • @pradeepkumar-cr8ph
    @pradeepkumar-cr8ph 3 года назад +2

    Is,This,coulm size is applicable,for both type of building commercial and resedential.

  • @DilipSingh-oz6fy
    @DilipSingh-oz6fy 2 года назад +1

    Sir maine apne plot 32.5×76 ke liye naksha banwana hai...apka phone number

  • @khairullaskar596
    @khairullaskar596 10 месяцев назад +1

    Deep kitna korna he

  • @khaninayat8994
    @khaninayat8994 3 года назад +2

    Helo sir mene 9*9 colum pe grund flor banay he ab me G+1 banana he kiya bna sakta hu mere ghar ka aria he 28×40 total 15 colum he ples raply

  • @prashantpol933
    @prashantpol933 2 года назад +7

    Can I use 9" X 24" columns for G + 6 building? Thanks in advance

    • @myengineeringsupport
      @myengineeringsupport  2 года назад +1

      No consult with structural engineer

    • @mirmohasinreza
      @mirmohasinreza 2 года назад

      😁

    • @dhawalbharwad8733
      @dhawalbharwad8733 Год назад

      Can i use 9 + 15 columms for G3 Residential Room. We used 25 mm steel bar in maine colum nd 12 mm 2 nd 3 flor ??

  • @vickychoudhary9793
    @vickychoudhary9793 2 года назад +1

    Bhai main 4 majila ghr bnwa rha hu kya mujhe sujhav de skte hai

  • @WithSimpleLife143
    @WithSimpleLife143 Год назад

    Mera collum 9 by 24 ka h ye kya sahi size.... Aur kitna manzil jaa sakta.... Hai.... Distance 2 collum k beech... 13.5 feet h... Plz sir riply kariye

  • @samirtanwar7908
    @samirtanwar7908 2 года назад +1

    जो समझाते हो उसकी एक image दिखा दिया करो
    क्या है की
    बार का अंदर और बाहर वाला समझ नहीं आया
    जो तुम नोट्स में समझा रहे थे

  • @dhruvarora4179
    @dhruvarora4179 2 года назад +1

    Pls tell G+4building me ground and first floor ke baad dealer coloum size kar raha hai is it right
    Upper ground tak 9x18 uske baad 1st floor pe 15x9
    Then upar ke 2 floor 12x9 or 9x9 karra hai
    Please answere

  • @rajkumar24352
    @rajkumar24352 2 года назад +1

    2 flor 1800 square feet home mein के पिलर में कितने सरिया और कितना mm का सरिया डालना चाहिए ?

  • @arjunseth5081
    @arjunseth5081 Месяц назад

    2 manjil me kalam aur bim size 15ft duri rakhanr par kya hoga

  • @mohdmahzar7330
    @mohdmahzar7330 2 года назад +1

    Hello sir Mera ghar G+2 hai 55 ,24 aur jis me 18 kalam 9 12 ke 6 12 ke baar hai kya Mai G+3 kar Sakta hu

  • @modanidarshana4247
    @modanidarshana4247 2 года назад +2

    Sir please tell me soon ...instead of 12* 12inch ...can I take 9*15

  • @sahilbedakyale3697
    @sahilbedakyale3697 3 месяца назад

    Pile size and reinforcement for g+1,2,3,4

  • @bhaskarsarkar5559
    @bhaskarsarkar5559 2 года назад +1

    Sir mera 27*25 fut mey g+1 ghar k liye 10"×10" colum size diya or 12 mm 6 nos tmt bar diye or colum to colum distance 3.5 meter diya kuch problem hoga keya? Plz advice 🙏

  • @sachiny4662
    @sachiny4662 Год назад +2

    Can we use 9 by 15 column for g+2 . Because wall size is 9 inch

  • @sagarjadhav9637
    @sagarjadhav9637 2 года назад +2

    Sir video is very important for us, sir what to take column size, and steel for P+5?

  • @incredibleshohratkhan4382
    @incredibleshohratkhan4382 3 года назад +1

    Sir jaise jaise buildin bante jaye column ka size b kam sakte hai ??? Jaise ground floor 12"×18" fir first floor 12"×16" fir second floor 12"×14", is tarah har floor pr km bhi krte jaa skte hai???? Pls pls reply

  • @KBSJodhpurBrothers
    @KBSJodhpurBrothers 2 года назад +1

    9*18 ke कॉलम में 16 mm ke 8 बार सही है 5 मजीले

  • @lakhangade2870
    @lakhangade2870 2 года назад +1

    Sir hamari jaga 18x21 he or hamara busment he or hamare total 8 coulm he or centar me coulm nahi li lekin 1 coulm se dusre coulm tak 18 feet bhim liya he or hamare coulm me 16 mm ke 4 or centar me 12 mm ke 4 Siriya use kiya he or upar bhi yahi he or flor 3 me chhoti coulm liya he or use coulm me 16 mm ke 4 or centar me 12 mm 2 siriya use kiya he or flor 4 ke coulm me sabhi coulm me 12 mm ke 6 siriya use kiya he to muje dar lagraha flor 3 ke coulm or flor 4 ke coulm o load le sakti he ya koi problem asakta he reply

  • @saurabhphatanagare8427
    @saurabhphatanagare8427 2 месяца назад

    6 * 18 size colume chalega kya ...... Niche parking aur upar makan keliye .... 6 inch bricks work karana hai.....

  • @md.farhan4960
    @md.farhan4960 2 года назад +4

    Thanks a lot for helpful information Sir 👍

  • @neerajsaini9248
    @neerajsaini9248 11 месяцев назад

    Sir maine 1 plot liya hai jiska size 28×27 hai .or uske columnka size 9*9 ke 5 column hai .jisme 16 ke 4 baar or 12 ki 2 baar hai or column distance 10 foot hai jo mujhe g+4 banana hai . Kya mujhe colum change karane padenge..

  • @satpalbhiduri8948
    @satpalbhiduri8948 2 года назад +1

    Sir m G+ 4 ke liye column size 9/15 le skta hu aur ush m 12 mm ke 8 sariya use kr skta hu aur mere column to column distance h 14 ft

  • @ramnarayanjatram3982
    @ramnarayanjatram3982 5 месяцев назад

    सर जी कॉन्टेक्ट नंबर प्लीज 🙏🙏

  • @MR.SM_MOTIVATOR
    @MR.SM_MOTIVATOR Год назад

    Sir, mere ghar ka plinth level ground level se 7 ft hai. Two storied building hoga. Abhi column kiya hai (10*10) aur 6nos 12 mm bar, aur beam kiya hai (10*12) 5nos 12 mm and extra top 12mm, slab hai 5 inch. Isse koi dikkat to nehi hoga. Please reply 🙏

  • @PMPlansDesign
    @PMPlansDesign 3 года назад +1

    Sir G+3 keliye column size 10" by 16" provide kar sakte hain ? Or beam size 10" by 15" provide kar sakte hain ?

    • @myengineeringsupport
      @myengineeringsupport  3 года назад

      size of an RCC column should be 12”x 12” (300mm x 300mm) with 6 bars of 12mm Fe500 Steel with m20 grade of concrete and stirrups of T8@6″C/C.

    • @PMPlansDesign
      @PMPlansDesign 3 года назад

      Acha . Lekin 10" by 16" dene se kuch problem hoga kya . In future 1 manjila bhi uske upar banana hai .matlab G+4

    • @helpmetoreach10kwithoutany14
      @helpmetoreach10kwithoutany14 2 года назад

      @@PMPlansDesign 12by 12 is sufficient and you have to change the reinforcement must go from down to up with 16mm of 4 and 12mm of 2 rods thnku

  • @amarkumarsingh6927
    @amarkumarsingh6927 8 месяцев назад

    building me to sir 9"/18" ka hi jada hota hai

  • @निलेशपटेल-ध4थ
    @निलेशपटेल-ध4थ 2 года назад +2

    Apka videos bahut help karta sir ji.... Nice video making

  • @ambarsharda6741
    @ambarsharda6741 Год назад

    Sir Apne Puri video me Column ke Ties ko Stirrups bola hai.....
    Difference is In columns we call them Ties and In Beams we call them Stirrups.
    Apne jo (G+4) Five Storey Building ki details btate time 8 no of bars wali drawing show nahi kari.....
    These are Thumb rules (basic rules) for understanding.....Nice video 😊

  • @mohdmahzar7330
    @mohdmahzar7330 2 года назад +1

    Hello sir Mera ghar G+2 hai 55 ,24 aur jis me 18 kalam 9 12 ke 6 12 ke baar hai kya Mai G+3 kar Sakta hu

  • @poojaprabhudesai4592
    @poojaprabhudesai4592 2 года назад +1

    Sir partition wall 4" aur 6 " ho to internal column kaise ayenge.please btayiye

  • @MadhuReddy782
    @MadhuReddy782 4 месяца назад

    Sir we used 9*14 columns, with 4 16mm and 4 12mm rods for g+3 with all 8mm rings, is this okay ...can the building sustain..

  • @prasadbanni8231
    @prasadbanni8231 Год назад +1

    G+4 Mai column size kab kam karni chahiye...hamare engineer ne ground floor ko 9×21 ke column Dale pr 1 floor kon 9×18 Kiya...ye chalta hai kya..

    • @呼呼是的
      @呼呼是的 2 месяца назад

      Nhi bhai engeriner 🤔 to kabhi asa nhi karega isse column mai bo strength nhi rehegi

  • @saudivlogs1259
    @saudivlogs1259 2 года назад +1

    Sirmujhe 20*25 ka hall banwana hai or Starers bhi banwane hai lekin callum side me hi chahiye beej meek bhi nahi to size or bar keya rakhe

  • @pankajguptacutebaby
    @pankajguptacutebaby 2 года назад +1

    70*41 plot size black soil footing better or pilling
    Agar footing to depth kitna bar size and column size please reply

  • @ganjamanja8797
    @ganjamanja8797 2 года назад +1

    Sir g+2 ke liya 4 tho 16 ka or 2 tho 12 ka de sakte he or size 12"*12" Plz reply sir

  • @निलेशपटेल-ध4थ
    @निलेशपटेल-ध4थ 2 года назад +1

    Hi,... Sir... How are you... I hope... You are well.... Sir mera apse ek sawal hai ap please uska jawab dena.. Please....
    Sir hamne ghar banaya tha 1 story home... Column ka size diya tha 9 into 9 or ghar ka area ha total 865 square feet hai... Sir hamre ghar me total 15 column lage hai...10 se 8 feet ke duri par . Or ab hm chahate ki uske upar or ek or story banana hai... Tho kya hm bana sakte hai ki nahi only or ek story ghar badana hai.. Matalb 2 manzil banana hai.... Foundation ka work tha 5 into 5..and depth 5..
    ..
    Second manzil ka sariya kya rakna hai ab... Pehle manzil ka sariya 10mm or 12mmm use huwa hai...
    Please reply

    • @myengineeringsupport
      @myengineeringsupport  2 года назад

      Ok column me steel kya use kiya

    • @निलेशपटेल-ध4थ
      @निलेशपटेल-ध4थ 2 года назад

      @@myengineeringsupport column me steel 6 bar use kiya tha 10mm ke 4 bar or 12mm ke 2 bar or 6mm ka square box 6inch ki duri par kiya tha.... Kya ab 2 story add kar sakte ki nahi....

  • @beautyofbengal2907
    @beautyofbengal2907 2 года назад +2

    May I use 4 nos 16 mm rod for 10"×10" column and beam for two storey house?

  • @Er.prashanthsingh
    @Er.prashanthsingh 8 месяцев назад

    What about 6 inch thick size columns

  • @kamjitpradhan1626
    @kamjitpradhan1626 Год назад

    Sir mera 25*75 ka ghar hai,mein usme 10*15 ka 10 column Diya hun aur 10*12 ka 8 column hai,,total column Mera 18 hai,is it safe for us

  • @nuruzzamansk1768
    @nuruzzamansk1768 Месяц назад

    Sir, if this pillar goes to four floors and make it 10/10 pillar, then don't we have to cut the rod, is there any other way, it would be better if we make a little design.

  • @Justamizing
    @Justamizing Год назад

    Sir 10"×12" pillar se G+2 bana sakta hai kya.pillar to pillar distance 12 feet se 14 feet hai aur pillar mai 4 nos.of T16, 2 nos.of T12 mm dia use kya hai

  • @GauravKumar-tu5ql
    @GauravKumar-tu5ql 2 года назад +1

    Sir column ka size kya hoga for g+2 and distance between two columns is 19ft

  • @pankaj9934
    @pankaj9934 Год назад

    15/30 ka plot size hai
    G+2 banana hai kya
    Colum 12/9 ki and 12mm 6 bars
    Plinth beam 9/9 ki and 12 mm 4 bars
    Floor beam 9/9 ki and 12 mm 4 bars
    Shai h ????????

  • @durgeshkumardubey10
    @durgeshkumardubey10 2 года назад +1

    G+3 floor ke liye 9x12 ke colom me 16mm ke 6 bar use kar sakte hai
    Plot size 18 x 30 and colom to colom distance minimum 7feet and maximum 10feet

  • @gangasahuenglish
    @gangasahuenglish Год назад

    15 fit*15 fit room hone me koi dikat to nai hoga

  • @ramakantadeori784
    @ramakantadeori784 Год назад

    8mm and 6mm mix karke deya hain stirrup

  • @sumitkumar-de8cc
    @sumitkumar-de8cc 2 года назад +1

    Sir 5 manjil makan me 12 mm 4 aur 16 mm 2 to koi dikat

  • @khaliquekhan6284
    @khaliquekhan6284 2 года назад +1

    SIR EK COLUMN SE DUSRE COLUMN KI DUR 22'-6" TO KITNE MM KE COLUMN DENE PAREGE SIR

  • @JAYMAAKAMAKHYADEVI
    @JAYMAAKAMAKHYADEVI 2 года назад +1

    क्या 5 मंजिले मकान में 9 ×18 इंच का पिलर दे सकते है, पिलर से पिलर की दूरी 15 फूट होगा

    • @myengineeringsupport
      @myengineeringsupport  2 года назад

      No

    • @JAYMAAKAMAKHYADEVI
      @JAYMAAKAMAKHYADEVI Год назад

      @@myengineeringsupportतो कितना size देना चाहिए column का distance 15 foot हो 5 storey building में🙏

  • @anilbagwe2542
    @anilbagwe2542 2 года назад +2

    Sir ji,
    Thanks for very knowledgeable information about concrete pillars.
    I have one query. Want to construct G 250 Sq ft +1 250 Sq ft small house adjacent to another nearby house.
    Adjacent house is ( ie it's flooring/plinth level) up side and propose construct land is 8' down side.
    Can you guide me if possible, in this connection how to build it. I will be building at my own.
    Thanks a lot for helpful information.

  • @rahulbharvad7292
    @rahulbharvad7292 Год назад

    Sir... Agar 3 manjila building me size column 12*15 rakhe ho and bar size me 25mm*4 rakhe ho to risk rehta hai kya???

  • @incredibleshohratkhan4382
    @incredibleshohratkhan4382 3 года назад +1

    Thanku so much for making this owsome vid, pls tell G+5 me kya column size rhega or kon se bar use krne padenge.column distance 14×11 hai.

    • @myengineeringsupport
      @myengineeringsupport  3 года назад +1

      For 5 storey,G+4 building the size of an RCC column should be 12”x 18” (300mm x 450mm) with 4 bars of 16mm and 4 bars of 12mm Fe500 Steel with m25 grade of concrete and stirrups of T10@6″C/ ...

  • @syaketyadav6310
    @syaketyadav6310 2 года назад +1

    Vak be baklol aise bahut sare galat idea or study kahapar kiyeho bhai

  • @ramakantadeori784
    @ramakantadeori784 Год назад

    Sir hum g+2 house bna rai mera reinforcement 6 nos 12 mm gadha 4 foot dept or footing 8 mm spacing 4 inch or pose ka size 10×12 kya yeh save hein g + 2 storey ke liye please reply me sir

  • @exam3247
    @exam3247 Год назад

    Sir, ghar k base me 16 mm Char column size 9*9 ha upar ja krr column ka diameter Kam hota ha to 12 mm Char me baad me 6 mm ka churi usse G+4 utha skte h kya???

  • @uddhavbhosale9382
    @uddhavbhosale9382 6 месяцев назад

    Sir mera ghar ground flower + 2 flower he or 9×15 ke collam size rakhi he ithana sahi he kya

  • @bishalmalakar4125
    @bishalmalakar4125 2 года назад +1

    Sir main 2 manjila imarat banana chahata honnn usmain 4 room hoga kitna cost ayeega

  • @pradeepbhokare3399
    @pradeepbhokare3399 Год назад

    Hallo sir, mare Ghar ke construction me 15 foot column ki length rakhi hai our column 9*18 inch column liya hai ye sahi hai kya sir our abhi bheam pooting se 3 foot uchi pe liya hai kitna mm ke our kitne road use kare

  • @daler75
    @daler75 7 месяцев назад

    Kya ham 9×18 me 4 सरिया 20mm ka aor 4 सरिया 16mm ka dal सकते hai?

  • @akashnath612
    @akashnath612 Год назад

    In our locality for 3 story house they normally use 4-16mm & 2-12mm... for 5 story it's 4-20mm & 4-16mm... So I guess ask a local engineer first...😑

  • @ayoubarshad697
    @ayoubarshad697 2 года назад +1

    Sir 3 story keliay 12 mm ki 8 bar use kr sukta Hain aur ye kaesa rahe ga jbke column to column distance 7 feet hae aur plenth beam main konsi bar perfect rahe gi

  • @inovativeabhijit3276
    @inovativeabhijit3276 2 месяца назад

    2 manjila ghar ke liye column ka rod size 12 inch ka and no of bar 6 ye best hein ya 16 inch ka rod and no of rod 4 , konsa best hein

  • @vikasseth5277
    @vikasseth5277 Год назад

    Sir ji 9/12 colum me 4bar 16mm our do bar 12 mm ke de ke g+4 normal house bna skte hai our ek colum se dusre kolum ki duri 10 fit ya 11 feet ho ....

  • @abhishekupadhyay6930
    @abhishekupadhyay6930 2 года назад +1

    Sir,
    My house with only ground floor was constructed in 2010 with only 10mm ×4 rod. Nw m planning to built 1st floor on tht house what should I do nw?

    • @myengineeringsupport
      @myengineeringsupport  2 года назад

      No mt bnana

    • @abhishekupadhyay6930
      @abhishekupadhyay6930 2 года назад

      @@myengineeringsupport sir can you guide me if i want to construct 1st floor bcoz my family is big wht should I do for the strength?

  • @monimadhavtaid4796
    @monimadhavtaid4796 6 месяцев назад

    Sir ji ghar ka hight bhi bota dijiye

  • @mdahmed3392
    @mdahmed3392 2 года назад +1

    *Bheem ka kya size houna chahiye wo bhi boliye please*

  • @Dutta-Engineering
    @Dutta-Engineering 3 года назад +2

    Plz make video on- Beam size .

  • @monikasatpal5018
    @monikasatpal5018 2 года назад +1

    Sir m G+4 ke liye column ka size 9/15 le skta hu aur mere column to column distance 14 ft h aur ush m 12 mm ka 8 dia use kr skta hu

  • @rahulsondhiya6013
    @rahulsondhiya6013 Год назад

    Sir, total area 450 sq feet total 9 columns of size 9*9 4 rods . Kya 16 mm dia rods use kr skte h mazbuti k liye. ???

  • @sanjayjha4281
    @sanjayjha4281 Год назад

    34x105 G+3ka plan chahiye & infront of xpress way

  • @Pragyanand01
    @Pragyanand01 Год назад +1

    Nice information sir... just need one clarity .. for g+4 can we use 12"x14" colum with 4x 16 bar and 2 x 12 bar ...mistri aise hi bata raha hai..sab jagah bana hua hai

    • @Vishaljaiswal75
      @Vishaljaiswal75 2 месяца назад

      @@Pragyanand01 sahi hai itna hi har jagah lagta hai

    • @CisPlatin-c5h
      @CisPlatin-c5h 6 дней назад

      kitna kharcha aaya total complete hone mai

  • @apurbabose8526
    @apurbabose8526 2 года назад +1

    10 /10 ka kalam pa 16 mm ka TMT Bar dakar kitna manjil ghar bansakta ha?

  • @Jaishreeram0751
    @Jaishreeram0751 2 года назад +1

    सर 16mm me total 13 पिलर 10" × 14" खड़े हैं और लगभग 1302 स्क्वायर फीट 21 × 62 मकान में जिंदल पैंथर का सरिए का उपयोग किया गया है तो कितने मंजिल तक ले जाना चाहिए

    • @myengineeringsupport
      @myengineeringsupport  2 года назад

      Kitne baar hai

    • @Jaishreeram0751
      @Jaishreeram0751 2 года назад +1

      @@myengineeringsupport सर 6 सरिए है एक पिलर में और लगभग 7 फुट की नींव रखी है

    • @myengineeringsupport
      @myengineeringsupport  2 года назад

      Ok h

    • @Jaishreeram0751
      @Jaishreeram0751 2 года назад

      @@myengineeringsupport sir kitni manjil banani chahiye yah Janna chahta hoon

  • @durgesh2015
    @durgesh2015 Год назад

    Sir, 9 inch by 18 inch column ki size me column to column maximum distance kya rakh sakte h?

  • @MAHESHKUMAR-gs5cu
    @MAHESHKUMAR-gs5cu Год назад

    Sr, please btaye ki ek room 10*10 and ek bathroom 6*4 ko banane le kya cost aayegi

  • @sumanmitra9587
    @sumanmitra9587 10 месяцев назад

    As per SP-16, all reinforceme ts are placed on the shorter dimension of the column.
    You placed all the reinforcements on the longer side ??

  • @vikalawa5301
    @vikalawa5301 Год назад

    Sir 30 × 50 ka plot hain 2 manjila
    Column ka size kitna hona chahiye

  • @naveensahu4972
    @naveensahu4972 11 месяцев назад

    ❤❤🎉😢

  • @CivilEngineerPrashantSingh
    @CivilEngineerPrashantSingh Год назад

    Sir yadi ek building me sabi column size ek Saath Lage ho to iska kya matalab hai.

  • @Sigmamale07-b7k
    @Sigmamale07-b7k Год назад +1

    Thank you Sir

  • @lavleshtindal
    @lavleshtindal Год назад

    Sir humne 70 fit hight leni hai starting colom size kya rhega

  • @modanidarshana4247
    @modanidarshana4247 2 года назад +1

    Roof beam and slab Ka BHI banaye AISA video

  • @aamaarukti4269
    @aamaarukti4269 2 года назад +1

    G+1 concrete beam ke upar iron beam lagake wooden slab, half wall rehega upar to column 8mm ka saria chalega🤔

  • @hollywoodmovieclips8217
    @hollywoodmovieclips8217 Год назад

    Sir low rise buildings mid rise buildings hai rise buildings kitne floor

  • @sarathamerica6712
    @sarathamerica6712 Год назад

    G+2 storey need four 16mm and two 12 mm... Is not it right???😊

  • @Pragyanand01
    @Pragyanand01 Год назад

    As per structural Engineer for G+4 column size should be 9"×18" with 4x16 bar + 4×12 bar...
    I am geting confuse As cost will be high with this double ring.. plz help

  • @sanjayaggarwal446
    @sanjayaggarwal446 Год назад

    Video acha h.
    Lakin bohot fast chala rahe ho.
    Screin shot leynay may dikkat hoti h.

  • @KBSJodhpurBrothers
    @KBSJodhpurBrothers 2 года назад +1

    Sir whatsup no

  • @zakirafridi3127
    @zakirafridi3127 Год назад

    sir can you please clear k ye thumb rules frame structure klye hai ya load bearing structure qu k deehat mai mostly load bearing structures bnty hai.

  • @prakashsalawria9274
    @prakashsalawria9274 2 года назад +1

    sir 5 storey building me footing konsa best h slopped ya stepped?

  • @aliqadri4672
    @aliqadri4672 2 года назад +1

    Thanks sir ap say ye poochna tha kay 5 story building kay liey jo column size or rienforcement rahy ga footing say wo uper 5th floor tak jaty jaty same size or rienforcement rahy ga ya kam hoga ya barhy ga or beam or slab ka size or rienforcement ground floor say leky uper 5th floor tak jaty jaty kiya thickness or bars may koi diffrence ayga beam or slab kay ya nai plz reply zaroor krna sir.??

    • @myengineeringsupport
      @myengineeringsupport  2 года назад +1

      Aap upar jate huye column size or reinforcement size km kar sakte ho jitna km load utna km size kr sakte ho

    • @aliqadri4672
      @aliqadri4672 2 года назад +1

      @@myengineeringsupport mera matlab hay kay jo column footing say jitnay size or rienforcement ka nikal raha hy or 5 th floor tak jaey ga to is surat may column ka size or bars neechy say or uper tak kiya same dimension or bars rahein gy ya koi tabdeeli ayegi uper waly columns may ..matlab kay jo bars column may hain os say uper wala column ki bar os say zyada thick hongi ya less hongi dia may..???or sary floor same construct hongy aik jesy

    • @myengineeringsupport
      @myengineeringsupport  2 года назад

      It's totally depends on your budget

  • @spencergaming783
    @spencergaming783 2 года назад +2

    G+5 kaha ha