Column size and sariya details for 1 storey,2 storeys,3 storeys, 4 storeys & 5 storey house
HTML-код
- Опубликовано: 30 сен 2024
- Disclaimer - This video is for educational purposes only. Copyright Disclaimer under section 107 of the copyright act 1976, allowance is made for "fair use" for purposes such as criticism, comment, news reporting, teaching, scholarship and research. Fair use is a use permitted by copyright statutes that might otherwise be infringing. Non-profit educational or personal use tips the balance in favour of fair use.
Column size and sariya details for 1 storey,2 storeys,3 storeys, 4 storeys & 5 storey house
In this video we know about column size and sariya details for Single storey building, double Storey building, 3 storey building, 4 Storey building & 5 storey floor building and also know about what is minimum and maximum distance between two-column. Ek manjila Makan, do manjila Makan, 3 मंजिला मकान और 4 मंजिला मकान के लिए कॉलम का साइज और सरिया क्या होना चाहिए. column size for G+0, G+1,G+2,G+3 Building construction.
#RCCColumnStandardSize #ColumnReinforcement #ColumnHeight
Topic Covered:-
Columns sizes for various floors
Column size and sariya details for 1 storey,2 storeys,3 storeys, 4 storeys & 5 storey house,
building design
various column sizes
what is the column size for the g+1 building
minimum column design
g+1 building design
column design
minimum size of column
column size for ground story building
different column sizes
apartment building column sizes
building design by staad pro
column size for 1 storey building
column size for 2 storey building
column size for 3 storey building
column size for 4 storey building
column size for g+0 building construction
column size for g+1 building
column size for g+2 building
column size for g+3 building
RCC Column Standard Size
RCC column standard size
the standard size of the column
standard column size residential building
RCC column size calculation
Bar Bending Schedule Basics: Especially for Freshers Civil Engineers (Bar Bending Schedule Part-1) Kindle Edition
amzn.to/3uvEMNo
My Social Media Link:-
Telegram Link:-
t.me/yoursengi...
Facebook page:-
/ yoursengineer
Facebook group:- / yoursengineer
Twitter link:- / yoursengineer
Instagram link:- / yoursengineer
Pinterest:- / _created
Linkedin:- / vishal-goel-17426a48
Website:- myengineeringsupport.com
Accessories I Use for making Videos
Mic I use - amzn.to/3r5f1S6
The laptop I use - amzn.to/3ayYNu3
Laptop Stand I Use- amzn.to/3cnILpj
_______________________________________________________
LIKE | SHARE | SUBSCRIBE FOR MORE VIDEOS LIKE THIS
~
THANKS FOR WATCHING! -ENJOY
===============================
Sir ham 1,2,3 Manjila makan ke liye faundesan khudai+ jali L size kitna rakhna hai,khudai kitna karwaye, abhi2 manjila de rahe hai please bataiye sir
Thankyou so much sir, bahut videos dekha par doubt clear nahi ho raha tha , par aapne sare doubts clear kar diye .. very informative video 😊🙏👏👏🤗🙏
My pleasure 🥰
Sir humhara 2 manjil hai column 10×10 hai aur usme 4 sariya 12 mm ki hai aur usme stripes 6/5.5 mm ki hai to sir es se koyi problem hoga kya?
For G+1 , column distance 4m . Column size 9*12 ,steel used 16mm 4pc and 12mm 2pc , is it safe?
Sir 9×9 inch column mai kya G+2 ya 3 manjil makaan bana sakte hai??
After g+2, I used 4 steel-16 mm dia and 2 steel -12 mm dia in my column, I have constructed G +4, is there any problem.
Is,This,coulm size is applicable,for both type of building commercial and resedential.
No only residential
Sir maine apne plot 32.5×76 ke liye naksha banwana hai...apka phone number
9996656740
Deep kitna korna he
Helo sir mene 9*9 colum pe grund flor banay he ab me G+1 banana he kiya bna sakta hu mere ghar ka aria he 28×40 total 15 colum he ples raply
Yes you can
Can I use 9" X 24" columns for G + 6 building? Thanks in advance
No consult with structural engineer
😁
Can i use 9 + 15 columms for G3 Residential Room. We used 25 mm steel bar in maine colum nd 12 mm 2 nd 3 flor ??
Bhai main 4 majila ghr bnwa rha hu kya mujhe sujhav de skte hai
Yes contact me
Mera collum 9 by 24 ka h ye kya sahi size.... Aur kitna manzil jaa sakta.... Hai.... Distance 2 collum k beech... 13.5 feet h... Plz sir riply kariye
G+5
जो समझाते हो उसकी एक image दिखा दिया करो
क्या है की
बार का अंदर और बाहर वाला समझ नहीं आया
जो तुम नोट्स में समझा रहे थे
Ok
Pls tell G+4building me ground and first floor ke baad dealer coloum size kar raha hai is it right
Upper ground tak 9x18 uske baad 1st floor pe 15x9
Then upar ke 2 floor 12x9 or 9x9 karra hai
Please answere
Yes no problem size km ho sakta h par bars nhi
2 flor 1800 square feet home mein के पिलर में कितने सरिया और कितना mm का सरिया डालना चाहिए ?
Minimum 4nos. @12mm
2 manjil me kalam aur bim size 15ft duri rakhanr par kya hoga
Hello sir Mera ghar G+2 hai 55 ,24 aur jis me 18 kalam 9 12 ke 6 12 ke baar hai kya Mai G+3 kar Sakta hu
Yes
@@myengineeringsupport As! Useful information
I want to discuss basement
Sir please tell me soon ...instead of 12* 12inch ...can I take 9*15
Not recommend
Pile size and reinforcement for g+1,2,3,4
Sir mera 27*25 fut mey g+1 ghar k liye 10"×10" colum size diya or 12 mm 6 nos tmt bar diye or colum to colum distance 3.5 meter diya kuch problem hoga keya? Plz advice 🙏
No it's ok
Can we use 9 by 15 column for g+2 . Because wall size is 9 inch
Sir video is very important for us, sir what to take column size, and steel for P+5?
Contact for structure drawing 9996656740
Sir jaise jaise buildin bante jaye column ka size b kam sakte hai ??? Jaise ground floor 12"×18" fir first floor 12"×16" fir second floor 12"×14", is tarah har floor pr km bhi krte jaa skte hai???? Pls pls reply
Bilkul kr sakte ho
9*18 ke कॉलम में 16 mm ke 8 बार सही है 5 मजीले
Consult with structural engineer
Sir hamari jaga 18x21 he or hamara busment he or hamare total 8 coulm he or centar me coulm nahi li lekin 1 coulm se dusre coulm tak 18 feet bhim liya he or hamare coulm me 16 mm ke 4 or centar me 12 mm ke 4 Siriya use kiya he or upar bhi yahi he or flor 3 me chhoti coulm liya he or use coulm me 16 mm ke 4 or centar me 12 mm 2 siriya use kiya he or flor 4 ke coulm me sabhi coulm me 12 mm ke 6 siriya use kiya he to muje dar lagraha flor 3 ke coulm or flor 4 ke coulm o load le sakti he ya koi problem asakta he reply
No problem
6 * 18 size colume chalega kya ...... Niche parking aur upar makan keliye .... 6 inch bricks work karana hai.....
Thanks a lot for helpful information Sir 👍
My pleasure🙏
Sir maine 1 plot liya hai jiska size 28×27 hai .or uske columnka size 9*9 ke 5 column hai .jisme 16 ke 4 baar or 12 ki 2 baar hai or column distance 10 foot hai jo mujhe g+4 banana hai . Kya mujhe colum change karane padenge..
Sir m G+ 4 ke liye column size 9/15 le skta hu aur ush m 12 mm ke 8 sariya use kr skta hu aur mere column to column distance h 14 ft
Yes
सर जी कॉन्टेक्ट नंबर प्लीज 🙏🙏
Sir, mere ghar ka plinth level ground level se 7 ft hai. Two storied building hoga. Abhi column kiya hai (10*10) aur 6nos 12 mm bar, aur beam kiya hai (10*12) 5nos 12 mm and extra top 12mm, slab hai 5 inch. Isse koi dikkat to nehi hoga. Please reply 🙏
Sir G+3 keliye column size 10" by 16" provide kar sakte hain ? Or beam size 10" by 15" provide kar sakte hain ?
size of an RCC column should be 12”x 12” (300mm x 300mm) with 6 bars of 12mm Fe500 Steel with m20 grade of concrete and stirrups of T8@6″C/C.
Acha . Lekin 10" by 16" dene se kuch problem hoga kya . In future 1 manjila bhi uske upar banana hai .matlab G+4
@@PMPlansDesign 12by 12 is sufficient and you have to change the reinforcement must go from down to up with 16mm of 4 and 12mm of 2 rods thnku
building me to sir 9"/18" ka hi jada hota hai
Apka videos bahut help karta sir ji.... Nice video making
Thanks
Sir Apne Puri video me Column ke Ties ko Stirrups bola hai.....
Difference is In columns we call them Ties and In Beams we call them Stirrups.
Apne jo (G+4) Five Storey Building ki details btate time 8 no of bars wali drawing show nahi kari.....
These are Thumb rules (basic rules) for understanding.....Nice video 😊
Hello sir Mera ghar G+2 hai 55 ,24 aur jis me 18 kalam 9 12 ke 6 12 ke baar hai kya Mai G+3 kar Sakta hu
Yes
Sir partition wall 4" aur 6 " ho to internal column kaise ayenge.please btayiye
Means?
Sir we used 9*14 columns, with 4 16mm and 4 12mm rods for g+3 with all 8mm rings, is this okay ...can the building sustain..
G+4 Mai column size kab kam karni chahiye...hamare engineer ne ground floor ko 9×21 ke column Dale pr 1 floor kon 9×18 Kiya...ye chalta hai kya..
Nhi bhai engeriner 🤔 to kabhi asa nhi karega isse column mai bo strength nhi rehegi
Sirmujhe 20*25 ka hall banwana hai or Starers bhi banwane hai lekin callum side me hi chahiye beej meek bhi nahi to size or bar keya rakhe
Approx 7lakh
70*41 plot size black soil footing better or pilling
Agar footing to depth kitna bar size and column size please reply
Go with Pile foundation
Sir g+2 ke liya 4 tho 16 ka or 2 tho 12 ka de sakte he or size 12"*12" Plz reply sir
Yes
Hi,... Sir... How are you... I hope... You are well.... Sir mera apse ek sawal hai ap please uska jawab dena.. Please....
Sir hamne ghar banaya tha 1 story home... Column ka size diya tha 9 into 9 or ghar ka area ha total 865 square feet hai... Sir hamre ghar me total 15 column lage hai...10 se 8 feet ke duri par . Or ab hm chahate ki uske upar or ek or story banana hai... Tho kya hm bana sakte hai ki nahi only or ek story ghar badana hai.. Matalb 2 manzil banana hai.... Foundation ka work tha 5 into 5..and depth 5..
..
Second manzil ka sariya kya rakna hai ab... Pehle manzil ka sariya 10mm or 12mmm use huwa hai...
Please reply
Ok column me steel kya use kiya
@@myengineeringsupport column me steel 6 bar use kiya tha 10mm ke 4 bar or 12mm ke 2 bar or 6mm ka square box 6inch ki duri par kiya tha.... Kya ab 2 story add kar sakte ki nahi....
May I use 4 nos 16 mm rod for 10"×10" column and beam for two storey house?
Yes you can
What about 6 inch thick size columns
Sir mera 25*75 ka ghar hai,mein usme 10*15 ka 10 column Diya hun aur 10*12 ka 8 column hai,,total column Mera 18 hai,is it safe for us
Sir, if this pillar goes to four floors and make it 10/10 pillar, then don't we have to cut the rod, is there any other way, it would be better if we make a little design.
Sir 10"×12" pillar se G+2 bana sakta hai kya.pillar to pillar distance 12 feet se 14 feet hai aur pillar mai 4 nos.of T16, 2 nos.of T12 mm dia use kya hai
Sir column ka size kya hoga for g+2 and distance between two columns is 19ft
Consult with structural engineer
15/30 ka plot size hai
G+2 banana hai kya
Colum 12/9 ki and 12mm 6 bars
Plinth beam 9/9 ki and 12 mm 4 bars
Floor beam 9/9 ki and 12 mm 4 bars
Shai h ????????
G+3 floor ke liye 9x12 ke colom me 16mm ke 6 bar use kar sakte hai
Plot size 18 x 30 and colom to colom distance minimum 7feet and maximum 10feet
Yes you can
15 fit*15 fit room hone me koi dikat to nai hoga
8mm and 6mm mix karke deya hain stirrup
Sir 5 manjil makan me 12 mm 4 aur 16 mm 2 to koi dikat
Yes
Kya dikat
SIR EK COLUMN SE DUSRE COLUMN KI DUR 22'-6" TO KITNE MM KE COLUMN DENE PAREGE SIR
Consult structure engineer
क्या 5 मंजिले मकान में 9 ×18 इंच का पिलर दे सकते है, पिलर से पिलर की दूरी 15 फूट होगा
No
@@myengineeringsupportतो कितना size देना चाहिए column का distance 15 foot हो 5 storey building में🙏
Sir ji,
Thanks for very knowledgeable information about concrete pillars.
I have one query. Want to construct G 250 Sq ft +1 250 Sq ft small house adjacent to another nearby house.
Adjacent house is ( ie it's flooring/plinth level) up side and propose construct land is 8' down side.
Can you guide me if possible, in this connection how to build it. I will be building at my own.
Thanks a lot for helpful information.
WhatsApp me
Sir... Agar 3 manjila building me size column 12*15 rakhe ho and bar size me 25mm*4 rakhe ho to risk rehta hai kya???
Thanku so much for making this owsome vid, pls tell G+5 me kya column size rhega or kon se bar use krne padenge.column distance 14×11 hai.
For 5 storey,G+4 building the size of an RCC column should be 12”x 18” (300mm x 450mm) with 4 bars of 16mm and 4 bars of 12mm Fe500 Steel with m25 grade of concrete and stirrups of T10@6″C/ ...
Vak be baklol aise bahut sare galat idea or study kahapar kiyeho bhai
Practical study h ye
Sir hum g+2 house bna rai mera reinforcement 6 nos 12 mm gadha 4 foot dept or footing 8 mm spacing 4 inch or pose ka size 10×12 kya yeh save hein g + 2 storey ke liye please reply me sir
Sir, ghar k base me 16 mm Char column size 9*9 ha upar ja krr column ka diameter Kam hota ha to 12 mm Char me baad me 6 mm ka churi usse G+4 utha skte h kya???
Sir mera ghar ground flower + 2 flower he or 9×15 ke collam size rakhi he ithana sahi he kya
Sir main 2 manjila imarat banana chahata honnn usmain 4 room hoga kitna cost ayeega
Plot size btao brother
Hallo sir, mare Ghar ke construction me 15 foot column ki length rakhi hai our column 9*18 inch column liya hai ye sahi hai kya sir our abhi bheam pooting se 3 foot uchi pe liya hai kitna mm ke our kitne road use kare
Kya ham 9×18 me 4 सरिया 20mm ka aor 4 सरिया 16mm ka dal सकते hai?
In our locality for 3 story house they normally use 4-16mm & 2-12mm... for 5 story it's 4-20mm & 4-16mm... So I guess ask a local engineer first...😑
Sir 3 story keliay 12 mm ki 8 bar use kr sukta Hain aur ye kaesa rahe ga jbke column to column distance 7 feet hae aur plenth beam main konsi bar perfect rahe gi
Ok h plinth beam minimum 12mm
Sir plenth beam main kitni rod honi chahea keon ke 3 story hae
2 manjila ghar ke liye column ka rod size 12 inch ka and no of bar 6 ye best hein ya 16 inch ka rod and no of rod 4 , konsa best hein
Sir ji 9/12 colum me 4bar 16mm our do bar 12 mm ke de ke g+4 normal house bna skte hai our ek colum se dusre kolum ki duri 10 fit ya 11 feet ho ....
Sir,
My house with only ground floor was constructed in 2010 with only 10mm ×4 rod. Nw m planning to built 1st floor on tht house what should I do nw?
No mt bnana
@@myengineeringsupport sir can you guide me if i want to construct 1st floor bcoz my family is big wht should I do for the strength?
Sir ji ghar ka hight bhi bota dijiye
*Bheem ka kya size houna chahiye wo bhi boliye please*
Already video available on channel pls check
Plz make video on- Beam size .
Tomorrow will come pls wait
Sir m G+4 ke liye column ka size 9/15 le skta hu aur mere column to column distance 14 ft h aur ush m 12 mm ka 8 dia use kr skta hu
Yes bro
@@myengineeringsupport sir kya aap ke no mil skte h
Sir, total area 450 sq feet total 9 columns of size 9*9 4 rods . Kya 16 mm dia rods use kr skte h mazbuti k liye. ???
34x105 G+3ka plan chahiye & infront of xpress way
Nice information sir... just need one clarity .. for g+4 can we use 12"x14" colum with 4x 16 bar and 2 x 12 bar ...mistri aise hi bata raha hai..sab jagah bana hua hai
@@Pragyanand01 sahi hai itna hi har jagah lagta hai
kitna kharcha aaya total complete hone mai
10 /10 ka kalam pa 16 mm ka TMT Bar dakar kitna manjil ghar bansakta ha?
4 storey
सर 16mm me total 13 पिलर 10" × 14" खड़े हैं और लगभग 1302 स्क्वायर फीट 21 × 62 मकान में जिंदल पैंथर का सरिए का उपयोग किया गया है तो कितने मंजिल तक ले जाना चाहिए
Kitne baar hai
@@myengineeringsupport सर 6 सरिए है एक पिलर में और लगभग 7 फुट की नींव रखी है
Ok h
@@myengineeringsupport sir kitni manjil banani chahiye yah Janna chahta hoon
Sir, 9 inch by 18 inch column ki size me column to column maximum distance kya rakh sakte h?
Sr, please btaye ki ek room 10*10 and ek bathroom 6*4 ko banane le kya cost aayegi
As per SP-16, all reinforceme ts are placed on the shorter dimension of the column.
You placed all the reinforcements on the longer side ??
Sir 30 × 50 ka plot hain 2 manjila
Column ka size kitna hona chahiye
❤❤🎉😢
Sir yadi ek building me sabi column size ek Saath Lage ho to iska kya matalab hai.
Thank you Sir
Sir humne 70 fit hight leni hai starting colom size kya rhega
Roof beam and slab Ka BHI banaye AISA video
Already available on channel pls check
G+1 concrete beam ke upar iron beam lagake wooden slab, half wall rehega upar to column 8mm ka saria chalega🤔
Use 10mm
@@myengineeringsupport ok sir thank you
Sir low rise buildings mid rise buildings hai rise buildings kitne floor
G+2 storey need four 16mm and two 12 mm... Is not it right???😊
As per structural Engineer for G+4 column size should be 9"×18" with 4x16 bar + 4×12 bar...
I am geting confuse As cost will be high with this double ring.. plz help
Video acha h.
Lakin bohot fast chala rahe ho.
Screin shot leynay may dikkat hoti h.
Sir whatsup no
9996656740
sir can you please clear k ye thumb rules frame structure klye hai ya load bearing structure qu k deehat mai mostly load bearing structures bnty hai.
sir 5 storey building me footing konsa best h slopped ya stepped?
Depending on soil conditions
Thanks sir ap say ye poochna tha kay 5 story building kay liey jo column size or rienforcement rahy ga footing say wo uper 5th floor tak jaty jaty same size or rienforcement rahy ga ya kam hoga ya barhy ga or beam or slab ka size or rienforcement ground floor say leky uper 5th floor tak jaty jaty kiya thickness or bars may koi diffrence ayga beam or slab kay ya nai plz reply zaroor krna sir.??
Aap upar jate huye column size or reinforcement size km kar sakte ho jitna km load utna km size kr sakte ho
@@myengineeringsupport mera matlab hay kay jo column footing say jitnay size or rienforcement ka nikal raha hy or 5 th floor tak jaey ga to is surat may column ka size or bars neechy say or uper tak kiya same dimension or bars rahein gy ya koi tabdeeli ayegi uper waly columns may ..matlab kay jo bars column may hain os say uper wala column ki bar os say zyada thick hongi ya less hongi dia may..???or sary floor same construct hongy aik jesy
It's totally depends on your budget
G+5 kaha ha
Watch Next part