📦QuinBoxed📦 Emergency EP.003: ZKETECH EBC-A40L

Поделиться
HTML-код
  • Опубликовано: 18 сен 2024
  • Sometimes I just want or need to use something that's still kept in a package lined up for a QuinBoxed and this is one of those times, let's unbox ( ;) ) and then take a quick first look at the ZKETECH BC-A40L a 40Amp Charger/Discharger for Lithium based energy cells!
    📝 Discord 📝
    If you like the channel and would like to discuss more join the Intermittent Technology Discord server here: / discord
    ░▒▓[Jump Links & Shopping links]▓▒░
    The links below are affiliate links and can earn me a small commission, this greatly helps out the channel, so if you do use the links, thank you very much!
    🔋 ZKETECH EBC-A40L Battery Charger/Discharger
    🪫 Aliexpress: s.click.aliexp...
    🪫 Amazon: geni.us/qoy5J
    📱 DOOGEE S98 Pro (Thermal camera phone)
    🔥 s.click.aliexp...
    ░▒▓[Music]▓▒░
    Intro&Outro
    TheFatRat - Xenogenesis
    During Video
    No music!

Комментарии • 20

  • @sevagj.b
    @sevagj.b Год назад

    Nice setup, many things to do and I will follow up
    Thanks

  • @DaveBoxBG
    @DaveBoxBG Год назад

    I am addicted to these.

  • @ScottyOutdoorAdventures
    @ScottyOutdoorAdventures Год назад

    HaHaHa...... damn you.... you got me!!! Loved the unboxing

  • @plemli
    @plemli Год назад

    Don't forget to check the individual cell voltages before you put them in parallel to further equalize them.
    I used my 4x10A lab supply and a 400W electronic load. Cycling 16 40Ah cells took ages. 280Ah will take eras 🙂

    • @IntermitTech
      @IntermitTech  Год назад

      What difference would the invidual cell voltage make if I'm going to equalize them anyway?
      My idea is to put them in series, have them equalize between themselves a bit and the charge to like 85% to 90% of the way, lots more watts like that.
      The disconnect everything, put it in parallel and then top balance them all. At that point, everything should be in the same state.
      Once in series again with BMS and load, any outliers would pretty quickly become apparent I think.
      I am doing individual tests right now, but that's more for the videos, so we'll see more about it in the future!

    • @plemli
      @plemli Год назад

      @@IntermitTech Well, when charged in series (even with an balancer) the cell voltages may (still) differ, and when next connected in parallel a large equalization current may flow. Best to check that the difference between the lowest and highest cell voltage is no more than 20mV or so. Keep in mind these large 280Ah cells can easily provide several kA.

    • @IntermitTech
      @IntermitTech  Год назад

      Ah like that, yes Thnx, that's a good reminder! That I do understand though and I don't except them to differ too much if I let them equalize a little bit after charging and use thick busbars to minimize any voltage drop.
      I have also planned a pre-charge resistor between the battery and inverters, maybe it could be useful here too if one of the cells is really out of balance.

  • @Mr.TonTop
    @Mr.TonTop Год назад +1

    Je kijkt (ook) teveel naar Andy van de offgrid garage 'from 🌞 hot Australia' 🐸

    • @IntermitTech
      @IntermitTech  Год назад +1

      Hahaha, zeker! Maar zoals gezegd, ik heb al redelijk wat ervaring met ZKETECH apperatuur en tot nu toe bevallen die ook prima!

    • @gubbernl
      @gubbernl Год назад +2

      Die is ook erg leuk, gave vent

    • @brentverhaegen1880
      @brentverhaegen1880 Год назад

      Andy ♥️

  • @victormultanen1981
    @victormultanen1981 Год назад

    impressive device though! thank you for sharing, and please make the video on topic the data acqisition of this charger-load.

  • @darthtater
    @darthtater Год назад

    Would be really cool if you could “close the loop” and charge low cells with full cells.

    • @IntermitTech
      @IntermitTech  Год назад

      How do you mean exactly? In theory if you connect 2 sells in parallel the higher voltage one will charge the lower voltage one and in the end balance out.

    • @darthtater
      @darthtater Год назад

      @@IntermitTech I think I worded my original comment poorly. What I mean is that you’re powering the charger/discharge from the wall then burning off 280ah to heat. Instead of losing the 280ah to heat on the discharge test, it would be cool if transfer that energy into discharged cells. Of course there would be losses.

    • @gubbernl
      @gubbernl Год назад

      What some people on the internet do, guys and girls, is use a complete batterypack for that.
      But that's the chicken and the egg:-)
      So, one 48v 16S pack, inverter and then the ZKE to charge each cell.
      Andries, as it looks like, you have enough cells for 6 batteries. (all for your self?;-)
      I suppose measure 16 cells, create one pack and use those + the inverter and ZKE to measure the next 16 cells. Build a pack with those -and because they are fully charged, charge the next 16 cells, etc.
      Afterwards you know all characteristics of each cell and can rearange the cells to create 6 optimal packs.

  • @OlavVitters
    @OlavVitters Год назад

    Would be nice to see you unbox every single one of those boxes, even if they're all the same!