I love to see this again, but with the CDHS-18 and CRL?....maybe take considerations? I work with these valves everyday! very informative presentation. thank you!
6:24 is wrong Because when the valve open it will not allow the flow from downstream to the main valve It is one direction flow from the main valve to downstream so the correct it will allow the flow in the top chamber to be evacuated through the pilot to downstream not vice versa
Wish videos where around in 70's. Very good
Thanks! Having to learn control valves and it would be a much bigger battle without these walk throughs
The best one valve I have experiencef in my 42 years service
Nice presentation
I love to see this again, but with the CDHS-18 and CRL?....maybe take considerations? I work with these valves everyday! very informative presentation. thank you!
That is a great suggestion, more animation videos coming!
Glad to hear it!
6:24 is wrong
Because when the valve open it will not allow the flow from downstream to the main valve
It is one direction flow from the main valve to downstream so the correct it will allow the flow in the top chamber to be evacuated through the pilot to downstream not vice versa
Muchas gracias. Thank you so much.
would the damaged diaphragm in the CRD cause preasure fluctuation on the outlet?
Sabes, mucho Senor gracias.
I need repair kit of CRD model in Qatar .
From where I can get?
Useful
👍👍👍👍👍👍👍
FIRST! LADWP. Oh Yeah!! very informative video.