Cleaning of heat exchanger by hydrojet

Поделиться
HTML-код
  • Опубликовано: 28 дек 2010

Комментарии • 31

  • @DanielBobrow_ISR-ARG
    @DanielBobrow_ISR-ARG  10 лет назад

    This exercise was done as part of a study on Quality Control of hydrojet cleaned tubes using an AcousticEye-made Acoustic Pulse Reflectometry (APR) instrument .
    I agree with those that did not like the safety conditions and I know the plant has been replacing this manual method with automatic cleaning systems.

    • @seanmaloughney
      @seanmaloughney 6 лет назад +1

      I was interested in using your footage here for a video doing just that; describing the benefits of automated cleaning vs manual. If you are willing to let me use this footage please reply!

    • @DanielBobrow_ISR-ARG
      @DanielBobrow_ISR-ARG  5 лет назад

      @@seanmaloughney Sorry I'm so late in replying. You certainly can use this video.

  • @Blackcatholman
    @Blackcatholman 12 лет назад +1

    Been on the bundle slab myself a few times.

    • @neyazalam4873
      @neyazalam4873 5 лет назад

      What is the pressure of fluid flow????????????

  • @vinodvanshiwal47
    @vinodvanshiwal47 4 года назад +1

    Sir i am from india My experience of hydro jetter is more than 6 years and I have 60 hydro jets.

  • @yaroubibrahim2096
    @yaroubibrahim2096 2 года назад

    What is the specification

  • @ponarpressure3999
    @ponarpressure3999 3 года назад

    welcome to us - new technologies of cleaning heat exchangers with high water pressure

  • @angelvillarruel1374
    @angelvillarruel1374 Год назад +1

    Buenos días
    Soy de Ecuador
    Como puedo obtener información para la adquisición de estos equipos para realizar el mantenimiento preventivo

  • @Xhippi3kill3rX
    @Xhippi3kill3rX 10 дней назад

    Definitely isn’t at BP. You’d get kicked off for doing shit like that.

  • @lilakb4700
    @lilakb4700 Год назад

    Which company

  • @Forthemove
    @Forthemove 10 месяцев назад

    Quite the primitive way of safely performing work

  • @jeninp993
    @jeninp993 7 лет назад

    how much pressure of flowing liquid

    • @DanielBobrow_ISR-ARG
      @DanielBobrow_ISR-ARG  7 лет назад

      Hi Jenin,
      They applied 8,000 psi but, after obtaining more experience and discussing this matter with others, I would recommend applying above 13,000 psi. The problem would be that this level of water jet pressures makes it extremely difficult to handle the nozzle manually (not an impossible task at about 10 KSi though).

    • @q9260
      @q9260 3 года назад

      @@DanielBobrow_ISR-ARG Damn, that would me 900 Bar or more, this is some serious pressure

    • @DanielBobrow_ISR-ARG
      @DanielBobrow_ISR-ARG  3 года назад

      @@q9260 8000 psi = 552 bar and it's not enough pressure; 900 bar and above would be better for NDI.

  • @ajaykick8432
    @ajaykick8432 5 лет назад

    Anabeeb also working ⚒

  • @nikhirajboruah8107
    @nikhirajboruah8107 2 месяца назад

    Where is hard barricades

  • @bittukumar3758
    @bittukumar3758 7 лет назад

    hello

  • @bittukumar3758
    @bittukumar3758 7 лет назад

    hello