This exercise was done as part of a study on Quality Control of hydrojet cleaned tubes using an AcousticEye-made Acoustic Pulse Reflectometry (APR) instrument . I agree with those that did not like the safety conditions and I know the plant has been replacing this manual method with automatic cleaning systems.
I was interested in using your footage here for a video doing just that; describing the benefits of automated cleaning vs manual. If you are willing to let me use this footage please reply!
Hi Jenin, They applied 8,000 psi but, after obtaining more experience and discussing this matter with others, I would recommend applying above 13,000 psi. The problem would be that this level of water jet pressures makes it extremely difficult to handle the nozzle manually (not an impossible task at about 10 KSi though).
This exercise was done as part of a study on Quality Control of hydrojet cleaned tubes using an AcousticEye-made Acoustic Pulse Reflectometry (APR) instrument .
I agree with those that did not like the safety conditions and I know the plant has been replacing this manual method with automatic cleaning systems.
I was interested in using your footage here for a video doing just that; describing the benefits of automated cleaning vs manual. If you are willing to let me use this footage please reply!
@@seanmaloughney Sorry I'm so late in replying. You certainly can use this video.
Been on the bundle slab myself a few times.
What is the pressure of fluid flow????????????
Sir i am from india My experience of hydro jetter is more than 6 years and I have 60 hydro jets.
What is the specification
welcome to us - new technologies of cleaning heat exchangers with high water pressure
Buenos días
Soy de Ecuador
Como puedo obtener información para la adquisición de estos equipos para realizar el mantenimiento preventivo
Definitely isn’t at BP. You’d get kicked off for doing shit like that.
Which company
Quite the primitive way of safely performing work
how much pressure of flowing liquid
Hi Jenin,
They applied 8,000 psi but, after obtaining more experience and discussing this matter with others, I would recommend applying above 13,000 psi. The problem would be that this level of water jet pressures makes it extremely difficult to handle the nozzle manually (not an impossible task at about 10 KSi though).
@@DanielBobrow_ISR-ARG Damn, that would me 900 Bar or more, this is some serious pressure
@@q9260 8000 psi = 552 bar and it's not enough pressure; 900 bar and above would be better for NDI.
Anabeeb also working ⚒
Where is hard barricades
What about the suicide gun
@@Colby-cy7sl forrealll
hello