Ma sha Allah boht asani se out put a.c. voltage ki setting fix volt k variable se kar k dikhaee lekin direction nhn batae k kis taraf ghumaney se volt kam ya barhein gey.
Video bht achi bnai, samjaya bi achi tra, lkn mechanic se rabita isliy krna pre ga q k ye clymeter tu gher mn nai hota ye kafi costly hota hy. Plz ye bat bi zehn mn rakhen.
Awsome guide by u akash babu.....or ye OVER LOAD ki variable kis kaam aati hein...kindky bta dein....agr es pr already video bni hy tou kindly link share kr dein.
Nice video , me ne Apne desi ups me solar panels and controller charger lgaya hy, output me high voltage ac 390 tk show hota hy jb load deta hoo pher normal hota hy,
AA Allah give you jannat because your helping the humanity. my question is this mayra ups bar bar module jalata hay may is ki jajga igbt lagana chhata hu2kw ups kay lay katny ampere igbt lag gaou.
Pakistani viewers request to you Ups k kon kon sy variables hyn jo hum use kr skty hyn Jesy charging volt float chargin auto cutt off charging variables kis purpose k liye kon sa variables use krty hyn iski video link send krye ga Agr nhi hy koi video tu bna kr video link send kejiye
,,hi sir new model microtek pcb board hai usme prisettings sirf ek he hai, problem eh hai k out put voltage power jane per karib 300 tak araha hai ,,,aur battery charging b 18 amps se horahi hai,,, uska fault kya hai please batavo ,,, ho saketo video banao,,,,aap k reply ka intezar me hu sir.....
اسلام و علیکم جناب! آپ سے گزارش ہے کہ اپنی زبان یعنی مکمل اردو میں بات کیا کریں تاکہ آپ ایک مہذب اور پڑھے لکھے ہونے کا ثبوت دیں یہ بیچ میں انگلش کے الفاظ استعمال کرنے سے گریز کریں اور اچھے اور محب وطن ہونے کا ثبوت دیں. شکریہ جزاک اللہ
Dring BNA k dykhain JIS main transformer ki or card or modul ki wazhe sating dykhain q k u p s main JGA Kum HOTI hy Nazar ASANI sy nhi ATA .yea to bager box k open wirng KR k Dy khain Shukria
But in my ups board voltage control variable is not present and my ups output voltage is low range bw 150 whats solution when voltage control is not in board.
Sir meray pas ib 104 kit me ajeeb msla aa rha hay. Kbi main pr shift hor jata hay to kbi ups pr. Main low wali verable b change kr k dakgi hay. 140 wali setting b ki hay variik say. Lakin phr b asa hi krta hay. Relay charging pr jati hay or jb charging wala load shuru hota hay to wo bnd ho jata hay ya ups pr shift ho kr pr main or asa bar bar krta rehta hay.
Akash bhai mere pas 1500 watt ka ups ha is Mai light bar bar fluctuate Kar rahe ha LED light be ise waja sy kharab ho Gaye ha Iska Kia karna chahe battery Mai masla ha yah ups Mai please reply
Mere pas systek ups he ..jb light jati he to ups srif 1.2 energy saver hi chalata he fan on kro to tirp kr jta he .or ups se gard gard ki awazen b aati hn kia problem hogi plz reply me
Sir hellp me sir kal rat ko mare ups ne out pot nekalna chora hain jab wabda hota hain per tek hota hain aur jab wabda chale jaeye to ups bhi kam ni karta hain battrey bilkul new hain battrey full hota hain
Mery pass aik ups jis main imran ka card hai, us main 4 variables hain, main, battary low, battary full and p-leak. Is main ye out put setting kaisy ho. Light jay tu fans slow ho jaty hain.
Sir kit name ib4 ab0308 me msla ye hay k jb wapda on krtay hayn to ups ps shift ho jata hay or jb wapda off krtay hay to wapda wali charging show honay leg jati hay. Tmaam veriable new legay hay. Main low k pas ic ki bjay 2 autocupler hay. Taqriban hr chez check kr k dakh li hay yha tk k main ic b dosri kit ka lega kr dakha hay lakin same problem a rhi hay please koi hal btany. Sirf main ic hi nae chotay ic b change kr k dakhay hayn lakin koi hal nae nikal rha.
Dear sir. i have made a 500 watts this UPS. its giving 220 volts output but its Hertz are 200Hz showing. so where is the fault? in which part of the module? how to correct it? be informed that when i made this UPS, mistakenly in the beginning i provided 24v DC batteries instead of 12v DC battery, the main board got damaged. I replaced the main board so giving 220v ac output but hertz are ner not ok, showing 200 HZon DMM, Pleas tell me how to correct it?
Bhai mujhy bhi help krde hanare pas bhi asi ups ha usme voltage zyada ata ha phele hamare pas tar thy usme voltage 180 190 aty thy ab cable lagi ha to 220 arha ha pura pr usme ups trip hojata ha to betry charge nahn horha trip hojati ha kabi kabar cable me koi falt ata ha jise voltage kam hojaty hen to betry sahi charge hojati ha to sir ap thori help krden gy ups ko voltage 180 200 mile us kelye kia karna hoga koi divade lagai hogi ya ander serkit me setting hogi so plz help krden
Asslamo alikum Akash, mery ups ki kit per digipower likha hua hy, tariq ki kit k naam se bhi mash-hoor hy. Iss per fix volt ka variable nahin hy, sirf 3 variable hain, battery high battery low or main low. Main kaisay output volt theek kr sakta hoon. Help kerain plz
Sir computer chalane k liye kitna voltage rakhna hoga Sath me agar 2 table fan aur ek amplifier rahe tab. Problem hota h ki main line aane par .. computer off ho jata h ...load me
akash Babu inverter 1200 va ka h....lekin agar output 280 volt kiya jaye tab ..jab main line kam voltage ka anne par..same problem ho jata h ..kyuki voltage me difference aa jata h..
Sir please koi hal btayn. Q k is ki wapda wali tar utaar b dayn to charging hoti rehti hay. Jb battry ki tar utartay hayn to ruk jati hay or jesay hi battry ki tar legatay hayn to phr charging krna shuru ho jata hay jb k wapda ki tar b nae legi hoti.
aslamo alikum sir mera ups charge kar rha he betrry doosre ups pr bilkul sai chal rahi pr mera ups betrry low keh rha he pls pls pls pls iska bare btyain sir pls me wait karoo ga
Mein ny bahoth video's dekhi lkn sch mein jo ap ny smjhaya hai acha lga ❤❤ thanks
Thank you so much! Men ne abhi with in 2 minutes UPS ki voltage set kr li
Thanks a lot
I repair my ups by myself....
Like from tabriz.iran
your way of explaining is awesome
Very informative video for those who want to resolve problems in home.
Thnx bhi atny ghor sy btany ka allah ap ko or bhe kmyab kren
میں تمام ویڈیوز دیکھتا اور بھت اچھی ہوتی ئ
Ma sha Allah boht asani se out put a.c. voltage ki setting fix volt k variable se kar k dikhaee lekin direction nhn batae k kis taraf ghumaney se volt kam ya barhein gey.
Aapne bahut achchhe se voltage change Karna batata, dhanyawad!
Kya inverter ki frequency BHI change Kar sakte Hain?
Video bht achi bnai, samjaya bi achi tra, lkn mechanic se rabita isliy krna pre ga q k ye clymeter tu gher mn nai hota ye kafi costly hota hy. Plz ye bat bi zehn mn rakhen.
Awsome guide by u akash babu.....or ye OVER LOAD ki variable kis kaam aati hein...kindky bta dein....agr es pr already video bni hy tou kindly link share kr dein.
Very informative and accurate video i have verified this very nice
Good work 👍 but pls ups main board ko check krnay ka tareeqa Bata Dy or main board k connection pls detail k sath ...bohat shukriya
Nice video , me ne Apne desi ups me solar panels and controller charger lgaya hy, output me high voltage ac 390 tk show hota hy jb load deta hoo pher normal hota hy,
Very good bhai.....
maza aa gya ...shukrya
Brother very very good and thanks for this information video
Thanks bro acha program hai or tafsel sy bataty ho good job
Incredible video!Fantastic video!
Very good presentation thanks
Assalamu alikum sir apki video mujy bohat lagi mara masla ya ha k mara ups kam voltig daraha ha os k baray plz bata dy.
Nice video bahi jan
Min or max battery ki vedio b bna dain g
Akash babo, pls power factor capacitor k bary me koi idea den
Sir invater ki output pe stabilazer laga sakte hr kaya. Or problem kaya hoga
Bohat khob shokriya bahaye
Nice, 12 volts old local ups ke ac 220 output ke lia konsa new kit achha hoga, kia ye sine wave ups bi tyaar ho Sakta hy
Mereko sikhna hai bhai mujhe bhi apna shop kholna hai bhai mera sport kro na bhai
janab akash bhai ap ups ke ic ke bare mein zarur btaye ga yeh teen ic kia kia kam karte hain aur kon kon si section mein mojood hain
AA Allah give you jannat because your helping the humanity. my question is this mayra ups bar bar module jalata hay may is ki jajga igbt lagana chhata hu2kw ups kay lay katny ampere igbt lag gaou.
Nice video and full informative, Thanks
Bagher box k wiring KR k Dy khain taky wiring clear Nazar aye transformer modul or card ki wiring thanks
Thank you ❤❤❤❤❤❤❤❤
Bhai Jan ❤❤❤❤❤❤❤❤
fix volt ka Pich tait karne se bejle kam hoti hai ya loz karne see....???
بائ جان ۔جب ups ان ہو اور بجلی اے تو وہ چارجر جلاتے ہے ۔تو پیلز اپ ایک وڈیو کرنا
Out class video thns sir
Mera bi purana transfarmer wala ups hy, Eska bi ac volts 300 se bi above show hota hy, Eska purana kit hy, isme konsa new kit fit kia jaae
UPS charging boost button ke setting aur detail batain
Akash bhai may ni naya ups banaya hay ap k videos ko follow kr k . Lekin mera ups load nahi utha raha plz rahnumai kre.thanx
Good work bro
video is informative but you made it so long by repeating every thing 5 times
Ge good bahi Mera ups par fan slow chalta ha kaya karo
Uska fix voltage wala variable check karo agar theek hai to us se zyada kar lo aur agr kharab hai to New Laga lo okay ho jaega
Very nice video
Hi nice job, this is Revocatus from Tanzania please help to know where can I buy that board (charging control board/UPS board). Thanks
Thank you so much sir your idea working
Assalamu Alaikum bhai jaan main yah puchna chahta hun Ki UPS ke transformer Ke Jal Jaane Ki Surat mein only battery output Kis Tarah Li Ja sakti hai
mere pas pc wala ups hai wo 250output ac volt de raha hai usko kam karke 220 karna hai hoga ya ni
Love your work.
Pakistani viewers request to you
Ups k kon kon sy variables hyn jo hum use kr skty hyn
Jesy charging volt float chargin auto cutt off charging variables
kis purpose k liye kon sa variables use krty hyn iski video link send krye ga
Agr nhi hy koi video tu bna kr video link send kejiye
,,hi sir new model microtek pcb board hai usme prisettings sirf ek he hai, problem eh hai k out put voltage power jane per karib 300 tak araha hai ,,,aur battery charging b 18 amps se horahi hai,,, uska fault kya hai please batavo ,,, ho saketo video banao,,,,aap k reply ka intezar me hu sir.....
Excellent videos sir
Salam kase hai app
Module main irfp 150n ko kase check kren ok hai ya nhe reply
Bhai ups ka transfarmer backup nhi dy raha hai kia us mn sada inverter lg jy ga k nhi bata do
Veri nice si
اسلام و علیکم جناب!
آپ سے گزارش ہے کہ اپنی زبان یعنی مکمل اردو میں بات کیا کریں تاکہ آپ ایک مہذب اور پڑھے لکھے ہونے کا ثبوت دیں یہ بیچ میں انگلش کے الفاظ استعمال کرنے سے گریز کریں اور اچھے اور محب وطن ہونے کا ثبوت دیں. شکریہ جزاک اللہ
Dring BNA k dykhain JIS main transformer ki or card or modul ki wazhe sating dykhain q k u p s main JGA Kum HOTI hy Nazar ASANI sy nhi ATA .yea to bager box k open wirng KR k Dy khain Shukria
Very nice video.
Luminus ka bhi same aisa hi hai?
Sir amron pure sine wave 880 ko 230 out se 260 kar sakte hai kya
Jazak Allah
اگر نئی بیڑیاں لگا دیں اور فل چارج ہوں تو کیا یو پی ایس 220 volt دے گا ؟ یا زیادہ دے گا ؟
Kya yah presets sbhi inverter mein hote Hain
Understand 👍😊
Good morning.. I have one ups making triple noise...please guide me.thanks.
Great work...thanks for making this wonderful video for us.
4 pankha h 500 am ka inverter h pankha bahut slow chalete plz koi Upay bataye...🙏🙏🙏🙏🙏
But in my ups board voltage control variable is not present and my ups output voltage is low range bw 150 whats solution when voltage control is not in board.
Mera inverter battery par slow chala hai or main line par fasat . Kya problem ho sakya hai plz mujhe bataye
bhai kia ups k 7 2 bettry lga sakty he mtlb 24 vol de sakty he
nahi laga sakte 2 battery lagani hai to ap ko 24v ka ups lena ho ga
i like your video
Very nice video!
Very nice video! Keep it up.
Sir meray pas ib 104 kit me ajeeb msla aa rha hay. Kbi main pr shift hor jata hay to kbi ups pr. Main low wali verable b change kr k dakgi hay. 140 wali setting b ki hay variik say. Lakin phr b asa hi krta hay. Relay charging pr jati hay or jb charging wala load shuru hota hay to wo bnd ho jata hay ya ups pr shift ho kr pr main or asa bar bar krta rehta hay.
Us ka light plug check karo jismein shoe Laga rahe ho
Bahe UPS charge na krta ho to kasy sat kr shkty ha
Very good
Input voltage is 274 v ac that's why inverter goes on ups mode, they show mains off.what should be do
Keep it up ☺️
Akash bhai mere pas 1500 watt ka ups ha is Mai light bar bar fluctuate Kar rahe ha LED light be ise waja sy kharab ho Gaye ha Iska Kia karna chahe battery Mai masla ha yah ups Mai please reply
IS KA module check karo aur volt kam karo aur is ki output par 1.6 ka copsatar laga do
Mere pas systek ups he ..jb light jati he to ups srif 1.2 energy saver hi chalata he fan on kro to tirp kr jta he .or ups se gard gard ki awazen b aati hn kia problem hogi plz reply me
Bhai jan ye btain k keay pta chaly gha k knsa ups kitny watt ka ha
Transformer sa pata chalta hai
Kia out put pay 2.5uf ka capacitor laga sakty hain
Ap 1.5uf laga lo
Sir hellp me sir kal rat ko mare ups ne out pot nekalna chora hain jab wabda hota hain per tek hota hain aur jab wabda chale jaeye to ups bhi kam ni karta hain battrey bilkul new hain battrey full hota hain
Ups k front par jo switch hai us ko badal do ok ho Jaye ga
Sir kons switch plz apna wattsapp number dado
@@kpksolarsolution4989 ap ko mein APNI video ia link deta Hun us ko Dekh lo ap Ka Kam huo Jaye ga ruclips.net/video/j1XV1tUFAsw/видео.html
Sir mery ups ma out put par double phas arahi ha mean k netal ki jaga bhi phase araha
Akash babu battary na ho tu variable power supply se kitna DC current ups ko dain as a replacement of battary?
14.3 volt par dc supply se cut off setting karo
Mery pass aik ups jis main imran ka card hai, us main 4 variables hain, main, battary low, battary full and p-leak. Is main ye out put setting kaisy ho. Light jay tu fans slow ho jaty hain.
Sir kit name ib4 ab0308 me msla ye hay k jb wapda on krtay hayn to ups ps shift ho jata hay or jb wapda off krtay hay to wapda wali charging show honay leg jati hay. Tmaam veriable new legay hay. Main low k pas ic ki bjay 2 autocupler hay. Taqriban hr chez check kr k dakh li hay yha tk k main ic b dosri kit ka lega kr dakha hay lakin same problem a rhi hay please koi hal btany. Sirf main ic hi nae chotay ic b change kr k dakhay hayn lakin koi hal nae nikal rha.
Dear sir. i have made a 500 watts this UPS. its giving 220 volts output but its Hertz are 200Hz showing. so where is the fault? in which part of the module? how to correct it? be informed that when i made this UPS, mistakenly in the beginning i provided 24v DC batteries instead of 12v DC battery, the main board got damaged. I replaced the main board so giving 220v ac output but hertz are ner not ok, showing 200 HZon DMM, Pleas tell me how to correct it?
Agr is k 220V ho gay tu iski betry timing pa b koi fark pra ga k nh mara ups k V290 pa set tha wo boht jaldi betry khtm kr data ha ????
Ahsan bohat zeyada fark parta hai bekab zeyada ho jata hai
Me ne solar plate lgai he desi ups pr ac output 293 he koi issue he iska pr normal he ab kuch
Bhai mujhy bhi help krde hanare pas bhi asi ups ha usme voltage zyada ata ha phele hamare pas tar thy usme voltage 180 190 aty thy ab cable lagi ha to 220 arha ha pura pr usme ups trip hojata ha to betry charge nahn horha trip hojati ha kabi kabar cable me koi falt ata ha jise voltage kam hojaty hen to betry sahi charge hojati ha to sir ap thori help krden gy ups ko voltage 180 200 mile us kelye kia karna hoga koi divade lagai hogi ya ander serkit me setting hogi so plz help krden
Us ki charging ampere Kam Kar do ok ho Jaye ga
@@akashbabu2739 bhai kahn se kam hoty impair koi setting hoti ha kia thora ap bata den
Nice information
Asslamo alikum Akash, mery ups ki kit per digipower likha hua hy, tariq ki kit k naam se bhi mash-hoor hy. Iss per fix volt ka variable nahin hy, sirf 3 variable hain, battery high battery low or main low. Main kaisay output volt theek kr sakta hoon. Help kerain plz
Us k leye new kit lagni ho hi is kit se Nahi hote Han transfarmar se ho jate hein magr wo ap se Nahi ho ga
@@akashbabu2739 thank you so much akash babu
Sir computer chalane k liye kitna voltage rakhna hoga
Sath me agar 2 table fan aur ek amplifier rahe tab.
Problem hota h ki main line aane par .. computer off ho jata h ...load me
Computer k leye 280 volt aur ye batao ups kitne whaat Ka hair
akash Babu inverter 1200 va ka h....lekin agar output 280 volt kiya jaye tab ..jab main line kam voltage ka anne par..same problem ho jata h ..kyuki voltage me difference aa jata h..
Great job
akash ap good ho
thanx dost
Sir please koi hal btayn. Q k is ki wapda wali tar utaar b dayn to charging hoti rehti hay. Jb battry ki tar utartay hayn to ruk jati hay or jesay hi battry ki tar legatay hayn to phr charging krna shuru ho jata hay jb k wapda ki tar b nae legi hoti.
Us ka mein ka variable change kar do ok ho jaye ga
Sir, UPS ke voltage 230 pe set kiye hen but ager 300W ka load pday to voltage 170 pe a jatay hn kia wjah hai?
Fantastic video!
aslamo alikum sir mera ups charge kar rha he betrry doosre ups pr bilkul sai chal rahi pr mera ups betrry low keh rha he pls pls pls pls iska bare btyain sir pls me wait karoo ga
Battery low variable check karo
Wonderful video.
Slam broo mry pas be ya wala ups ha. Or mra ups charging jald khtam krdata ha is ke kya waja ho skti ha.