I am very happy that a series of videos are being uploaded from you, but at the same time my kind request is that you give priority to the plumbing layout for 4 house related video that I had with you before.
Bro ippo oru circuit leh neutral wire light ku fan ku connected pannelam nu sonninge but ippo light oru neutral wire fan ku oru neutral wire wiring panna trip aaguma bro
I appreciate your efforts and teaching please can you clarify the in one circuit neutral one to connect the equipment or separate neutral for every equipment
hi , my landloard is stealing current , once current goes i have inverter and can see the landlord house blub are lit , and when i immediately turn of inverter the bulb goes off. Is there any law to sue the Landloard for stealing the current???
RCCB இல்லாத பழைய வீடூகளில் EARTH எப்படி வேலை செய்கிறது.... RCCB இருந்தா EARTH LEAKAGE ல் TRIP ஆகுது... பழைய வீட்டு WIREING ல் FUSE CARRIER மட்டும் உள்ளது, அதில் EARTH எப்படி WORK ஆகுது
ELCB: ELCB is working based on Earth leakage current. These devices measured the voltage on the earth conductor; if this voltage was not zero this indicated a current leakage to earth. RCCB: RCCB has no connection with the earth wire and that’s why it can trip when both currents phase and neutral are different and it withstands up to both the currents are same.
தங்களின் காணொலியை இன்று தான் பார்த்தேன். தொழிற் பயிற்சி நிறுவனங்களைக் காட்டிலும் மிக தெளிவாக சொல்லித் தந்துள்ளீர்கள். நன்றி.
நான் எதிர் பார்த்த வீடியோ மிக்க நன்றி
நல்ல தகவல் கொடுத்தமிக்கு நன்றி இன்னும் நல்ல தகவல்களை கொடுக்க ஆண்டவர் உங்களை ஆசீர்வதிப்பாராக
நன்றி
இதுபோன்ற தெளிவான பதிவுகளை இன்னும் எதிர்பார்க்கிறேன்...... 👍👍👍👍👍
thank you surly we will upload video
தெளிவான வீடியோ மிக்க நன்றி சார்
மிக்க நன்றி
Super bro. How to check our home Earthing is perfect explain bro.
video will upload soon bro
Thanks for your service and help.
Thank you very much sir. Good explanation. Very good teaching.
thank you sir
I am very happy that a series of videos are being uploaded from you, but at the same time my kind request is that you give priority to the plumbing layout for 4 house related video that I had with you before.
Thanks for the idea video will upload soon
அருமையான பதிவு 👌
நன்றி
Thanks sir, very useful for me
நல்ல தகவல் வீடியோ சூப்பர்சகோ
நன்றி சகோ
சிறப்பு சகோ.
நன்றி சகோ
Bro ippo oru circuit leh neutral wire light ku fan ku connected pannelam nu sonninge but ippo light oru neutral wire fan ku oru neutral wire wiring panna trip aaguma bro
detailed explanation bro 👌
thanks bro
Super Learning Sir
Thank you sir
U Welcome
Arumai annaa nanri
thanks bro
சிறப்புங்க...
நன்றி
Very nice explain
Thanks for liking
Excellent, very useful, thanks
welcome
Super bro good explanation 👌👍
thanks bro
Good information thank you sir
welcome sir
Super explain sir
thank you sir
Great sir. Can you Explain lift wiring
video will upload soon sir
உங்கள் வீடியோ டெமோ வீடியோ எனக்கு மிகவும் மிகவும் பிடித்திருக்கிறது ஆர் சி சி பி பற்றி சொன்னீர்கள் வாஷிங் மெஷின் மூலமாக தெரிந்துகொண்டேன்
thank you
Cone winding ribbon breaker working video kidaykuma sir
I appreciate your efforts and teaching please can you clarify the in one circuit neutral one to connect the equipment or separate neutral for every equipment
thank you video will upload soon
Sir neutral wirela ams irukku
But shock adikkala
Super bro
Thank you bro
sir,
if current leaks through earth means ,rccb trips?if so we should not use earth and rccb together?
if earth leakage is more than 30 Mili amps then it will be a problem
சூபர் சார் நன்றி
மிக்க நன்றி
hi , my landloard is stealing current , once current goes i have inverter and can see the landlord house blub are lit , and when i immediately turn of inverter the bulb goes off.
Is there any law to sue the Landloard for stealing the current???
Super
Supper
Super sir
thank you sir
Phase ல இருந்து current nuteral ல போகுதுனு சொல்லரிங்க...ஏன் nutral ல tester வச்சா லைட் எறிவதில்லை
video uploaded for yours command
Thanks bro
3phase la Rccb sir
already video uploaded
RCCB இல்லாத பழைய வீடூகளில் EARTH எப்படி வேலை செய்கிறது....
RCCB இருந்தா EARTH LEAKAGE ல் TRIP ஆகுது...
பழைய வீட்டு WIREING ல் FUSE CARRIER மட்டும் உள்ளது, அதில் EARTH எப்படி WORK ஆகுது
What is the difference between ELCB and RCCB....
ELCB:
ELCB is working based on Earth leakage current. These devices measured the voltage on the earth conductor; if this voltage was not zero this indicated a current leakage to earth.
RCCB:
RCCB has no connection with the earth wire and that’s why it can trip when both currents phase and neutral are different and it withstands up to both the currents are same.
@@techforallneeds thank you.
@@techforallneeds ppppp0ppp00ppp0ppp0
@@techforallneeds 0p0ppppppppp ppp000pppppppppppp
@@yokeshps143 p0pp
சார் நீங்கள் SPD WIRING எப்படி பண்ணுவது என்று வீடியோ போட்டிருக்கிறீர்கலா இருந்தால் லிங்க் அனுப்புங்க சார் நன்றி
ruclips.net/video/lONdWRF9Jjg/видео.html
Bro rcb மற்றும் rccb enna வேறுபாடு வீடியோ போடுங்கல்
video will upload soon bro
Ok
நண்பா மீட்டர்ல இருந்து பீயூஸ் கேரியல்லுக்கு வருது ஒயர் மெயின் பாக்ஸ்க்கு முன்னாடி பீஸ்கேரியலுக்கு அப்புறம் RCCB பொறுதலாமா சொல்லுங்க
ruclips.net/video/7K2Q9yr_HL0/видео.html
வீட்டில் ஒயரிங் களுக்கு ஆர் சி சி பி எப்படி பொருத்துவது
already video uploaded
ruclips.net/video/7K2Q9yr_HL0/видео.html
சகோ 3 phase rccb
மிகா தெலிவனா வீடியோ போடுங்கல் நான் காத்திருக்கிறேன்
we will upload soon practical video bro
போர் ஸ்டார்டர் on செய்யும் போது மட்டும் trip ஆவது ஏன் ?
may be OLR problem
வீட்டு ஒயரிங் களுக்கு ஆர் சி சி பி பொருத்தலாமா ஆர்சி சிபி பற்றி சொன்னீங்க பழைய வீட்டு ஒயரிங் களுக்கு ஆட்சி சிபி போடலாமா
yes use pannalam
ⓥⓔⓡⓨ ⓖⓞⓞⓓ
Thanks