excellent boiler ! I worked 5 years with that brand.
Also from my experience I would like to add such information. When we change our key from auto to manual mode FO 3way valves always changes to HFO side . It’s very important to note . If your boiler before breakdown was on MGO mode you should be aware that in case of emergency operation your valve will be turned automatically to HFO side !!!!! I have faced with this case we could not start the boiler and nobody knows it !!!!
Thank you Konstantin for your valuable information!
Getting alarm "S1B1 IO link error" on Mission OL boiler.Please advise.
I think it is due to communication of your local unisab panel with the pc in engine control room.Try to replace unisab of no1 aux boiler.
sir how to change the battery for unisab?
It is very easy in new models you just remove and place new one.As long as you have power not any problem.The battery is the reserve power for the parameters to keep them in place within memory in case of power failure.
I have got experience with this operation within one month every day
Nice hope to see you at our aux boiler course so we can listen your experience too!