Techniques of Plinth Beam Bars Installation

Поделиться
HTML-код
  • Опубликовано: 4 мар 2023
  • НаукаНаука

Комментарии • 49

  • @jaganraj226
    @jaganraj226 Год назад +28

    No hooks in stirrups, no development length... Totally wrong.

  • @vigneshdhivya9271
    @vigneshdhivya9271 11 месяцев назад +7

    10mm la poduringa bilding enna aagurathu

  • @cristianosimas1493
    @cristianosimas1493 Год назад +4

    Aqui na minha terra existe uma coisa chamada banca de ferragem.a coluna e as pernas agradecem.

  • @merchanthandson5271
    @merchanthandson5271 10 месяцев назад +8

    It should have L bend connecting rebar to vertical column not just straight and tied.

  • @mariaaparecidasanchessan-cu1rp
    @mariaaparecidasanchessan-cu1rp Год назад +2

    Necessita dobrar a ferragem nos encaixes.

  • @nammaareaengineer4810
    @nammaareaengineer4810 Год назад +3

    Column joint la ..L rod illayaa ... building strength enna ahhum ...

  • @civilengineeringworld3532
    @civilengineeringworld3532 Год назад +6

    You are using 10 mm bars for plinth beam 😮 minimum 12mm 4 to 6 nos should be used for ground floor.

    • @dev2946
      @dev2946 Месяц назад

      It's 8mm

  • @miguelt5012
    @miguelt5012 Год назад +3

    Mi tío que era albañil tomaba la medida de la varilla que hiba colocar y le aumentaba 20 centímetros. Y ya puesta en su lugar con los anillos le hacía un gancho de 10 centímetros en cada punta. En las cadenas, los castillos, la losza en todo le hacía ganchos y los amarraba con alambre.

  • @capthoatnuochanoi8321
    @capthoatnuochanoi8321 Год назад

    Good job

  • @Ahmad_7777
    @Ahmad_7777 Год назад +2

    Is tarike ke kaam se bache. Normal peoples should understand ye ghr nhi kabr bna rhe hai

  • @Tuyen980
    @Tuyen980 7 месяцев назад

    Công việc tôi yêu thích,các bạn làm việc tốt quá

  • @oFrankMartino
    @oFrankMartino Год назад +1

    Trumps wall starts in Bangaladesh

  • @lokeshsaroj4197
    @lokeshsaroj4197 10 месяцев назад

    Development length must be provided

  • @MeShow168
    @MeShow168 10 месяцев назад

    ហាយ ប្រូ

  • @wollotubemidya3741
    @wollotubemidya3741 Год назад

    naice

  • @meena8983.
    @meena8983. 6 месяцев назад

    Akdum kabada

  • @user-dr7oh4sj2y
    @user-dr7oh4sj2y 11 месяцев назад

    klass

  • @Btudu-u7n
    @Btudu-u7n 12 дней назад

    Tumhara.ring.nehi.huya

  • @odilonmachadodasilva4964
    @odilonmachadodasilva4964 9 месяцев назад

    Perfeito

  • @Navneetsingh-fg4gy
    @Navneetsingh-fg4gy Месяц назад

    Development length not provided… It is wrong practice

  • @joaquinperonalucas5027
    @joaquinperonalucas5027 Месяц назад

    Esos ladrillos no sirven de nada ,si los has puesto para aislar la armadura del terreno te has equivocado por que los ladrillos son muy porosos y no sirven para eso

  • @a_salam
    @a_salam 7 месяцев назад

    Why is there steel bar on the side that's not compression nor tensile part

  • @hasannawaz5520
    @hasannawaz5520 Год назад

    If the depth of beam exceed 750 mm then we have to provide face reinforcement which is wrong here

    • @montyshonty8953
      @montyshonty8953 11 месяцев назад

      Depth of beam is not exceeded above 355 mm

    • @hasannawaz5520
      @hasannawaz5520 11 месяцев назад

      @@montyshonty8953 good

  • @kabagyanvlogs8715
    @kabagyanvlogs8715 Год назад

    Pirmi nga nalalaing talaga agitoy nga indiano.. kitam man laing.. ngem awan lang PPE da kanayun.. heheheh😊😊😊

  • @nammaareaengineer4810
    @nammaareaengineer4810 Год назад

    ruclips.net/user/shortslkR01eJ0tVI?feature=share
    Ethay Pola column grade beam joint la ..L use pannunga

  • @factsofuniverse.science
    @factsofuniverse.science 2 месяца назад

    Extra rod ko o side me denene ki koi jarurat nehi accha hota bottom me 3 bars and top me 3 bars dete, kue ki beam ka main load beach me bottom ki laraf and column ke pas top me hota hai naki side me
    L bend karte column ke andar, ring ko 135⁰ hock karna chahiye,
    Kya kar rahe ho ye sob, same paise me isi se accha house banta,

  • @naveenmsd_
    @naveenmsd_ 6 месяцев назад

    No development length, no proper stirrups spacing

  • @yrcryptoguy
    @yrcryptoguy Год назад

    Column me 4 or beam me 6 rod 😂😂

  • @doordieyt3762
    @doordieyt3762 7 месяцев назад

    mat batao bhai galat kam dekhkar dimag satak ja raha 😮

  • @MohammedAslamtit-bitsoflife
    @MohammedAslamtit-bitsoflife 11 месяцев назад

    Wrong binding 135 angles are not given

    • @raghuprasath7631
      @raghuprasath7631 10 месяцев назад

      135 degree bending is not necessary because this is not sezmic zone

  • @debabrattiwari7928
    @debabrattiwari7928 6 месяцев назад

    Wrong technique. No devlopment length provided stirrup is wrong all wrong in this video

  • @manjuvirattu_jallikattu_lover
    @manjuvirattu_jallikattu_lover 10 месяцев назад

    Haha 10 mm beam

  • @LuisAntonioGuiang
    @LuisAntonioGuiang Месяц назад

    Xl

  • @LuisAntonioGuiang
    @LuisAntonioGuiang Месяц назад

    Iq

  • @MMariT
    @MMariT Год назад

    What on earth is that stupid background noise for? It's impossible to hear the voices.😮

  • @challammals4744
    @challammals4744 Год назад

    Bad centring. ..out work for in ......set..ok

  • @sanjibshaw5277
    @sanjibshaw5277 Год назад

    Wrong

  • @mariaaparecidasanchessan-cu1rp

    Amarraçào das ferragens correta

  • @kasturikhatun2795
    @kasturikhatun2795 9 месяцев назад

    Mashallah

  • @jaishankar7813
    @jaishankar7813 7 месяцев назад

    சொப்பு விளையாட்டு