Sir ek achha sa multimeter ka bare me bataye jo har jagah kaam aaye mere pass chota wala clamp on multimeter h par us se ove ka capacitor, DC Voltage etc. Chek nahi kar pate hh to ek achha sa multimeter kon sa le uske bare me bataye pls sir pls
carrier inverter Ac auto restart function not working,indoor unit flaps closing when electricity comes after power outage..then i havw manually start AC with remote.
Sir ek question hi thoda clear kardo plz R410a k suction 120 r discharged line 450 t0 500 barabar agar leak check karna hoto Kitna pressure dalkr check krskta ho plz answer me first
Jabtak sensors kharab toh chalega agar sahi sensor melanin toh lakin board mein problem ho toh AC ko fek do, nahi toh fake mechanics ka koi kami nahi hai, repair v nahi hoga aur paisa v jayaga.
Assalamo alaikum sir comment ke zarye aap se baat hua tha aap 3 month ka 10000 Bata ye the sir mai Ana chahta hoon aap ke training center me kaise contact hoga aap se please reply kijiega thank you sir
@@TechnicalGuruKazmi shukriyah sir aap reply kie sir wait karunga mai aap se hee training lerkar Kam karenge mai aap ka video one year and 6 months se dekhta hoon RUclips me aap ke jaisa dusra video nahi dekhe
Bahut hi achchha samghaya aap ne. Thanks bhai jaan 👍😘🇮🇳
Valeu!
Grato!
Muito boa dicas e ótima explanação!
Abraço!
Bom dia!
RJ - Brasil.
Good information sir
Inverter Ac complete troubleshooting and pcb repairs please explain sir iam waiting
Your voice is good 👍👍
Ok I will try-THANKS
Very good video
Its really very helpful. Thanks brother.
Sar main aapka bahut bada fan hun please reply me
Superb Kazmi bhai. You are great...👍
Thanks sir
Good sir
Thank you so much sir g 🙋
Good information sir ji
Thanks
Thank you Sir g 😘
Sir for example indoor ka sensor aur outdoor ka sensor dono ek saath defect ho jay ya 2 sensor outdoor ke defect ho jay kounsa errors code hoga
Very helpful video. Thank you sir.
Happy to help
H8
Where to buy component in Rawalpindi for the idu and odu PCBs.
Shukria aapka bohat sir ji🙏
Khurram sir kya fridge me sution pipe ki jagah par charging banaye and charging pipe ko sution line lagaye tho compressor karb hosaktahe?
no
@@TechnicalGuruKazmi ok sir
Very nice video sir
goods
Gas and services dono karke check kar liya
Wow nice
Good
Sir yah kon saye brand ka dc inverter ac hai kindly bta dien??
Sir ji sab company ke ac me same e3 e4 hi aayega ya alag alag aayeg
Alag alag aayege
Sir ek achha sa multimeter ka bare me bataye jo har jagah kaam aaye mere pass chota wala clamp on multimeter h par us se ove ka capacitor, DC Voltage etc. Chek nahi kar pate hh to ek achha sa multimeter kon sa le uske bare me bataye pls sir pls
FLUKE KA ACHA HAI
Thank u sir
hello sir mere pass LG dual inverter AC mein call sensor Lagane se compressor ka r p.m. kam rehta haiAgar nikal do to RPM badhta hai gas theek hai
carrier inverter Ac auto restart function not working,indoor unit flaps closing when electricity comes after power outage..then i havw manually start AC with remote.
Sir lg inverter ac hae usme ch38 likh kr aarha hae kya problem hai.
Sir alag alag compni ke ac me alag alag error ata he na ki E3-E4 sabhi compni me ayega ki sirf godrej me hi ayega
yes
Sir fir dusre company ke ac ka error code kaise pata karenge
@@TechnicalGuruKazmi yes kya matlab sir details me boliye
moin kmN sirf Godrej he mein ayega janab
Sir ek question hi thoda clear kardo plz R410a k suction 120 r discharged line 450 t0 500 barabar agar leak check karna hoto Kitna pressure dalkr check krskta ho plz answer me first
Sare leakage 150-200 me mil jate hain
Salam bro
salaam bhai
@@TechnicalGuruKazmi w s بھائی
@@TechnicalGuruKazmi oriant 1.5 ton dc inverter 1 ya dedh ghnta chal k e5 error py aa jata h
Jabtak sensors kharab toh chalega agar sahi sensor melanin toh lakin board mein problem ho toh AC ko fek do, nahi toh fake mechanics ka koi kami nahi hai, repair v nahi hoga aur paisa v jayaga.
Ok sir
Assalkm sir mera blue star ac thodi der chalta hai phir df code deta hai rukjata hai phir thodi derme jaljata hai
Please help sir
check tube sensor and ice formation on tube.. may be less gas
Sir 1 ton split mein dono pipe mein aur cooling coil mein ice aa rahi ho to kya ho sakta hai
gas leak check kren
Gas kam ya blor speed km
Sir ac ka gas bac karne ka video bhejo
it is available check in AC playlist
Sir inveter heair 1ton outer ka 2mint bad compressor band hojata ha phir 3mint bad on hojata ha Plis agar Mobil no daya da too achi tahra samja doo
सर इसका अगला वीडियो बनाओ ना
okey
Sir carrier aircondition compressor 10minat me off hi raha hai errors kuch bhi nahi ho raha hai
check amp when getting off if amps are high then check run capacitor/voltage/line droppage/comp heat and many more things
बिना रिमोट से on किये, इन्वर्टर सेमसंग स्प्लिट ऐसी चालू हो जाता हे के बार प्लीस इसकाभी इलाज दीजिए
Thenks
ok
Sar ji aap se help chahiye
kya btayen????
Pumpdown no loco.
🇧🇩
?
Hii
Assalamo alaikum sir comment ke zarye aap se baat hua tha aap 3 month ka 10000 Bata ye the sir mai Ana chahta hoon aap ke training center me kaise contact hoga aap se please reply kijiega thank you sir
Shabbir Khan Abhi start nhi hua hai November me contact kren kazmi687@gmail.com
@@TechnicalGuruKazmi shukriyah sir aap reply kie sir wait karunga mai aap se hee training lerkar Kam karenge mai aap ka video one year and 6 months se dekhta hoon RUclips me aap ke jaisa dusra video nahi dekhe
Shabbir Khan thanks brother
Sir kuch eroor is plate me nahi hote he
yes hote hain
Very nice video