Sealed System Looking for restricted capillary tube

Поделиться
HTML-код
  • Опубликовано: 16 июн 2024
  • Restriction? This is how to tell if your high side is restricted using a process tube adapter.
  • РазвлеченияРазвлечения

Комментарии • 98

  • @nchomey
    @nchomey 3 месяца назад +2

    This is fantastic. One quibble - water boils at 212,not 312. Or 100 if you aren't using freedom units.

  • @davebrunson125
    @davebrunson125 2 года назад +6

    you're right about heat restricting caps. It's POE I rarely rarely rarely ever changed a cap with R12 and 502 but since the introduction of POE it's common. If you work on commercial coolers and freezers you know. BOY do you go about the hard expensive way of testing for a restriction. If the unit is in vacuum do not add gas (I use to make that mistake). Turn the unit off and watch how fast the low pressure recovers, pretty much like you watch how fast it dropped with nitrogen. If it takes 5-10 min to stabilize it's restricted and not low. So prior to adding gas check for restriction 1st, by simply turning off the unit and watching the low pressure recover

  • @samuelsappliancerepair450
    @samuelsappliancerepair450 3 года назад +5

    Learned something new today. Thanks guys, Each imput to the class was great.

  • @Flytothesky12
    @Flytothesky12 2 года назад +4

    This channel is a jewel among all referigerant repair related video and for good learning man!!

  • @roberthaselwood8737
    @roberthaselwood8737 Год назад +3

    What a great teacher. I’m thinking about doing this.
    I wish I had someone like him to teach me. Will deffenetly watch all your videos!

  • @wasimedoo1506
    @wasimedoo1506 2 года назад +1

    Very good information bro thanks I could listen to you all the time looking forward for more of these videos

  • @qeesher
    @qeesher 2 года назад +4

    Thank you for great lectures! 👍

  • @Beemgod
    @Beemgod 3 года назад +11

    I just finished some sealed systems training a few hours ago. This video makes so much more sense now that i understand the steps. You are def an amazing instructor

    • @riz65
      @riz65 2 года назад

      Thanks

    • @peaclove2068
      @peaclove2068 Год назад

      Hey bro hope you’re doing well. Where did you get these trainings??

  • @Refrigeratortech
    @Refrigeratortech 2 года назад +3

    your lectures are really good and helpful. I liked it very much and learned a lot from your lectures. please keep posting your lectures. Also suggest your cameraman to cover all the equipment and items in film when working on it.

  • @valdimirputin
    @valdimirputin 2 года назад +4

    Get yourself a knee pad, all that kneeling will add up and your career of mountain climbing Everest when you retire will be hindered. Great videos, explains all systems in great details.
    Many Thanks

  • @andywurz6473
    @andywurz6473 2 года назад +2

    Very interesting. Huge amount of knowledge in that video

  • @issackaliaden9091
    @issackaliaden9091 Год назад +1

    Very interesting the best instructor ever thank you for your golden instruction I have learned a lot from you than my own instructor.

  • @justanoterguy314
    @justanoterguy314 Год назад +1

    Honestly I seen the video was an hour long and I thought it was going to be a bunch of mumbo jumbo jibberish talk but I listened and watched the whole thing. Great video man. Your a great teacher. I learned some stuff from this and just wanted to say thank you and good job. You rock 🤟I’m in a technical college right now learning hvac.

  • @emmanuelvictor2367
    @emmanuelvictor2367 2 года назад +2

    Excellent teaching, thank you

  • @djkingpersia
    @djkingpersia 8 месяцев назад

    This is a really good dude all the way presenting some really good and must have information. I'm here because of capillary tubes restrictions and running in a vacuum.
    You definitely have a lot of energy to present all of that information in 1! One bit of advice even though everything you are saying is music to my ears but for your students so much information at such a fast pace and then at different points random students are throwing out desperate questions
    I would highly recommend slowing the pace a little bit and focusing on one area at the time and maybe elaborate a little bit more.
    One last note as a student many years ago in the classroom and in the field one of the very first items that should be taught in my opinion is the magic of the metering device and what it does
    In layman terms refrigerant goes in at around 100° but comes out the other side around 40 degrees. Someone that is just getting into the field can really grasp that very basic example and then the rest of their education will be smooth

  • @minnesota-boston9620
    @minnesota-boston9620 Год назад +2

    So professional lecture. Thanks.

  • @damon6852
    @damon6852 2 года назад +2

    Excellent instructor!!!

  • @roeeovsey7773
    @roeeovsey7773 2 года назад +1

    Amazing Instructor 👏!

  • @elijandrosabayev
    @elijandrosabayev 2 года назад +1

    amazing training!

  • @Wasakaie
    @Wasakaie Год назад

    Great Video, good job explaining.

  • @irenovatedmv
    @irenovatedmv Год назад

    This is the kind of instructor I need. Break it all the way down for me, down to the basics, then build me up!
    Helluva Teacher…

  • @natigaghayev2044
    @natigaghayev2044 3 года назад +3

    Love your lessons!

    • @ronaldmanley9591
      @ronaldmanley9591 2 года назад +1

      Great teaching!! Where do i get the process tube adaptador?

    • @riz65
      @riz65 2 года назад

      @@ronaldmanley9591 sorry never saw your post, Amazon sells the process tube adapter kit.

  • @nicholusedwards
    @nicholusedwards 5 дней назад

    Great teacher thank you for that........ when you going to lecture us about the proper way of charging R600A gass

  • @curtisjones9157
    @curtisjones9157 Месяц назад

    Very very good video. I do service repair. I try to avoid.. working on sealed systems.. lots of Junk compressor today..
    But like to save old refrigerator.
    I have a blocked line..
    Capillary is flowing.. but lots of oil.
    This I saw.. just cutting.. the cap.. at drier. System was at 60 psi.
    Unplugged not running.
    I need to figure out if compressor..
    Valve.. May be sticking..
    I shut off the unit.. and it did not equalize.. Compressor tried to start.. was overloaded..
    Ptc tripped 2 times.
    Then it kicked off.. but pressure went to vacuum..
    Can the valves cause this..?
    I don't believe I have a restriction..
    But there is oil in cap tube..
    I'm going to flush the tube..?
    Advice or link.. to testing compressor would be great.
    These new Inverter compressor, especially LG run.. but have failed to pump.. I call them Junk..

  • @nicolous11
    @nicolous11 2 года назад +2

    Thanks for the Fantastic lesson, How do you call the testing valve kit that you are using in this lesson?

    • @riz65
      @riz65 2 года назад +1

      Robinair Process Tube Adapter Kit, I think Amazon sells it

  • @nelson_tutorial
    @nelson_tutorial Год назад +1

    Thanks a lot sir..

  • @TeslaWasHere
    @TeslaWasHere 6 месяцев назад

    Good rundown.
    Also, PSIA is absolute, not atmosphere. Makes more sense if you think about it.

  • @tbone6354
    @tbone6354 3 месяца назад

    A good idea is to fill the compressor with water before regassing to keep it cool while running

  • @yeyo-sz2cw
    @yeyo-sz2cw 3 года назад +6

    At 36:46. Water's boiling point is 212° F, not 312°F Lol. ..Good lesson though

    • @riz65
      @riz65 3 года назад +5

      You are correct, Lessons are not scripted and I messed up on that one. Thanks for watching.
      This shows you watched almost to the end, LOL

    • @tessiehuskey1
      @tessiehuskey1 3 года назад

      @@riz65
      i thought you said that was the boiling point of a type of freon

    • @riz65
      @riz65 3 года назад +1

      @@tessiehuskey1 If you watch 36:46 I was saying water boils, but Using the comparison of how water can boil then turn from a liquid to vapor/steam. Refrigerant does the same thing in a refrigerant system when it is heated is will turn from a liquid to a vapor/steam.

    • @sonofnok2153
      @sonofnok2153 3 года назад

      Alright. Well noted Mr. Newton, Galileo, or Einstein, whichever one you are.

    • @yeyo-sz2cw
      @yeyo-sz2cw 2 года назад +3

      @@riz65. I'm just realizing it i got a comment from the man himself. You made my day!! ..i watch your videos from start to end. They are a treasure!! Thank you for sharing your knowledge and experience with us. God bless you!

  • @natepeterson7145
    @natepeterson7145 Год назад +1

    Don't risk your fingers over saving refrigerant! There's internet posts on what can happen. Also if you use gloves make 100% sure there's no holes in it. The holes can trap refrigerant between your skin and gloves and can promote frostbite faster than you realize. In appliances it's pretty much not worth the risk with how much refrigerant these systems take so when in doubt let it out. Accidents aren't punishable by law at least for that amount.

  • @Ashroyer86
    @Ashroyer86 Год назад +1

    I probably can't make it to your class but would be happy to call and pay you for your help.

  • @sammyd7857
    @sammyd7857 2 года назад +3

    Most compressors don't have the access valve any more. The capillaries block because the filters are shit. Sometimes even the oil can block it.

    • @jb9652
      @jb9652 Год назад

      Thanks! 👍

  • @jeffgietl2086
    @jeffgietl2086 3 года назад +2

    This video is very informative but I have a question. All this work to get the refrigerator running wouldn't it just be easier and less expensive to just replace the fridge?? I was tought you should never work on a factory sealed system. But I enjoyed this video

    • @riz65
      @riz65 2 года назад +1

      If you were to be under factory warranty or extended contract you would repair this fridge, but the steps are the same for some of the more expensive refrigerators ranging from $10K to $15K, cheaper to keep her

  • @philliphall5198
    @philliphall5198 7 месяцев назад

    So the only way to get oil out off capillary tube is blow it out with nighten, if it’s full of oil then the compressor is low or some one put to much oil in system ??
    Does the container and capillary tube and filter all have to be replaced ???

  • @mrtheloverboy89
    @mrtheloverboy89 Год назад

    If you can post part number for that kit to tap into the lines , thanks

  • @iM-mf1ke
    @iM-mf1ke 8 месяцев назад

    Thanks!

  • @zuko19987
    @zuko19987 2 года назад

    Could you possibly do a video on adding a new Evap and heat exchanger in a bottom mount LG/kenmore elite model??

  • @MANwPLAN101
    @MANwPLAN101 10 месяцев назад

    This is fire 🔥

  • @user-ed2zb3vu9l
    @user-ed2zb3vu9l Год назад

    Great instructor, thanks for all your videos, sir.
    I have a couple of questions:
    1. Should a little bit of freon be added (to check pressure movement to determine if that is a leak or restriction) with the fridge turned OFF or it can be turned ON to see changes live?
    2. If pressure is negative on the low side and we need to find out whether the issue is restriction or leak. Can I turn the fridge OFF IF pressure didn't change, then this is a restriction, and if the pressure started to change, then this is a leak? Would this assumption be correct?
    3. Applying Nitrogen on low side to check for the restriction, will it be pushed to both low and high side (through the compressor)? Like if I cut capillary tube on normally working fridge, then apply Nitrogen, will I feel it from both sides of capillary tube or just from low / high side of it?
    THANK YOU!

    • @appliancetraining5600
      @appliancetraining5600 Год назад

      1. Yes you can add freon from the low side in vapor form and see if both side of the system respond, while it is running.
      2. if it was a leak pressure will rise if it is in a vacuum, how high depends on how much leaked out. At least minimum if a leak and there is no refrigerant left the pressure will return to 0 psi. RESTRICTIONS CAN BE PARTIAL, TOTAL OR FLOATING. So results after turning the refrigerator off vary.
      through the

    • @user-ed2zb3vu9l
      @user-ed2zb3vu9l Год назад

      @@appliancetraining5600 looks like your
      message hit a limit of letter numbers or something. Would be interested to know the answer on the 3rd question. Thank you very much

    • @riz65
      @riz65 Год назад

      @@user-ed2zb3vu9l if system is not restricted, and you charge with nitrogen, to lets say 100 psi if you cut the capillary tube and pressure should come out of both ends, if restricted may only come out of the cap tube side and not drier filter. The compressor depending on type of compressor and position of the piston sometimes charging through just process stub of the compressor may not push through compressor to the condenser.

  • @xdsone
    @xdsone 2 года назад +3

    Water boils at 212 14.7psi (atm) or sea level lol

  • @tonysu152
    @tonysu152 2 года назад +2

    I saw that nice tools adapter kit where I can buy ? Thank you

    • @eric_ad
      @eric_ad 2 года назад +1

      I also want that tool

    • @markcarpenter3600
      @markcarpenter3600 Год назад

      @@eric_ad Robinair 12458 - Process Tube Adapter Kit to 1/4 inch MFL

  • @CommonSenses101
    @CommonSenses101 2 года назад +2

    Hi guys. My bottom freezer refrigerator is about 8 years old and having the similar problem. I see frost at the joint between the small callipary tube and the evaporator tube. Then It melted, water started dropping. The temperature was between 28-48F. I did reset the fridge by unplugged/plugged. It didn't make any different. I did replace the start relay, capacitor, defrost thermostat, temperature sensor, and electric control board, still does not work. Is it worth to repair my fridge? And how much does it usually cost for vacuum/flush out moisture/oil out of the refrigeration, including replacing the drier filter? Please advise. Thank you.

    • @kkaresz78
      @kkaresz78 Год назад

      DId you change the drier filter ? My Maytag does the same, ices over the connection of the capilary tube with the lg tube (covered with C4), and it goes to the 1st loop (about 4 inches). Every fan works, compressor works, but it gets cold only at the connector area. Any ideas ?

    • @skullhart
      @skullhart 4 месяца назад

      ​@kkaresz78 Sounds like a restriction from moisture. Try taking a spray bottle with hot water and spray that area where the capillary tube enters the evaporator. Spray until the ice is gone and and it begins to thaw. If there is moisture frozen inside there you will hear popping and clicking indicating renewed flow of freon to the evaporator. I currently have this same issue and will probably need to purge the system with nitrogen and replace the dryer filter and recharge the system.

  • @manhpham8052
    @manhpham8052 3 года назад +3

    I wish the school i went got teacher likes him. I graduate 3.0 GPA dont know how to install A/C thermostat

  • @ozziewelcome5612
    @ozziewelcome5612 Год назад

    Good 👍👍

  • @rodgraff1782
    @rodgraff1782 Год назад +1

    The process tube adaptor kit is used in conjunction with the process tube pinch off tool to seal up hermetic sealed systems, instead of leaving access valves which can leak. All servicing is done thru the process tubes. They can be added to each side of the system or lengthened, do your work, thru the process tubes and pinch them off, remove your process adaptor, and seal the end with a braze, maintaining the sealed system.

    • @riz65
      @riz65 Год назад

      You're correct, I have been saying that for years. We can't pinchnand seal off 600a units the valves stay on.

    • @hobbyless4089
      @hobbyless4089 Год назад

      I just discovered this product, but why not braze a service valve? If brazed properly, and using a proper cap, it will not leak, a service valve could also give access for future service.

    •  Год назад

      @@hobbyless4089 Every time when you connect pressure meter to that process tube you are loosing too much refrigerant. Therefore on systems with less than 200 g of refrigerant, make them sealed!

    •  Год назад

      @@riz65 Offcorse you can! 2 pinch off pliers make job safe!

    • @appliancetraining5600
      @appliancetraining5600 10 месяцев назад

      . @NiksaMarkoviczvirka yes you can remove valves, but it's not safe, If you pinch of tool is leaking when you are trying to seal with a torch you have a flame hazard or explosive hazard, So I say this if you remove the valves which is possible, the risk is on you. So If I said its ok and somone does it incorrectly then I would be the one at fault

  • @SaresMLee
    @SaresMLee Год назад

    I'm putting fat fat like, thank you so much!

  • @flashgordon1695
    @flashgordon1695 Год назад

    just one additional point nitrogen is heavier than air and displaces it easily so when working with nitrogen you should do so in a well ventilated area our have exhaust fan running . nitrogen will knock you out so quick you will not know what hit you....and that will be the end . its very deadly .

  • @wingli9215
    @wingli9215 4 месяца назад

    Why the suction pressure should read at 0 psig while running ?

    • @TMMApplianceRepair
      @TMMApplianceRepair  4 месяца назад

      Those are the design pressures on a 134a system. High pressure is 120-130 psi depending on ambient temperature

  • @lothianmcadam1
    @lothianmcadam1 Год назад

    Today I learned... that "three hundred twelve" is the boiling temperature of water.

    • @riz65
      @riz65 11 месяцев назад

      I did point out was a mistake in another comment . these are live and unscripted, So id not make mistakes once in a while. , but it could be 312 at a different pressure,

  • @Ashroyer86
    @Ashroyer86 Год назад

    Lg linear low side -10, high side 225 after installing new compressor.

  • @vishnunanan8738
    @vishnunanan8738 Год назад

    I removed a freezer compressor and I open the compressor and water is inside no oil what happen with it

    • @appliancetraining5600
      @appliancetraining5600 Год назад

      Sorry I dont get email notifications of posts from viewers, if you have water in your system that most likely happen due to a low side leak like the evaporator, they run in a vacuum almost when cooling, so a small leak will make the evaporator run below 0 PSI and that would allow moisture/water to get sucked into the system

  • @markstevens2937
    @markstevens2937 7 месяцев назад

    Born teacher.

  • @MrJujubean
    @MrJujubean 5 месяцев назад

    Well last I knew water boiled at 212 NOT 312. Good grief!

  • @electrifysa
    @electrifysa Год назад

    What's the name of that tool ?

    • @markcarpenter3600
      @markcarpenter3600 Год назад

      Robinair 12458 - Process Tube Adapter Kit to 1/4 inch MFL

    • @tommyq374
      @tommyq374 Год назад

      He said process tube adapter.....

  • @tommyq374
    @tommyq374 Год назад

    310°f water will in fact boil

  • @shine-cg9uf
    @shine-cg9uf 2 года назад +2

    Ideal suction pressure for a refrigerator running with r134a in the system is 17psi which gives u a 18 degree evaporator temp n 38 box temp. 0 psi reading ur system needs proper troubleshooting.

    • @shine-cg9uf
      @shine-cg9uf 2 года назад

      22 psi for commercial refrigeration units using 134a. Domestic refrigerator with evaporator in freezer 0 to 3 psi..

    • @riz65
      @riz65 2 года назад +1

      Residential refrigerators run at 0 PSIG, have to remember these systems are a freezer with a refrigerator compartment. The pressures you are referring to are, if the unit was a stand alone refrigerator with no Freezer.
      In order to cool the freezer, the evap temperature has to be approximately -15 degrees Fahrenheit.

    • @shine-cg9uf
      @shine-cg9uf 2 года назад

      Yep I realized that after I sent it. I don't work on residential just commercial. But enjoy learning about the residential side n home appliances. Thanks

  • @tommyq374
    @tommyq374 Год назад

    If its a million psi the regulator would have a prv and release it lol, just use a regulator end of haha no questions

  • @hvac01453
    @hvac01453 2 года назад +2

    OMG... hope your students didnt record this... you referred to a filter drier as a drier filter, which is no big deal but never heard it called that, most call it a liquid line filter drier, because the suction line filter is normally only a temporary drier of sorts. also.. you continually call waters boiling point 312F.... when its actually 212F. I was supprised that not one student picked up on that, or questioned you about that. teach the students that if refrigerant liquid spills out, especially in winter, dont be a hero. let it fly. no need to get hurt doing this work. I've found that liquid stage usually turns to vapor after a few seconds anyway....but that liquid is bad frost bite.
    Your going to find it will be difficult for your students to "UNLEARN" something you've already taught them, and the high pressure from the condenser never leaves the bottom of the cabinet as you were pointing to the upper cabinet. It never leaves the bottom unless the cap tube starts in the upper cabinet. however, your cap tube,(like most), is down below. your teaching of the sponge and body temperature relationship was good. Teaching is no easy task.

    • @riz65
      @riz65 2 года назад +3

      I did correct myself when Tech2 pointed it out 9 months ago. This is a live lesson and unscripted as I do make some mistakes. Yes I did say 312' instead of 212'.
      It is obvious you are an AC tech not only by your screen name, but in your understanding of the system. Refrigerators have a loop called Yoder by some manufacturers and Hot Gas loop by others. This is an extension of the condenser which runs up around the freezer door to reduce exterior moisture from forming around the door gasket of the freezer, so you are incorrect about the high pressure never leaves the bottom of the cabinet.
      Although the capillary tube is a liquid line that term is rarely used on refrigerators and the Hot gas line does go up and back down to the bottom, look at this link half way down an example and explanation is given.
      appliancerepaircourses.com/home-appliance-refrigeration-technician-course/hart-course-module-three-sample/

    • @scotthale5335
      @scotthale5335 Год назад

      I saw your comment on the LLFD N laughed. I was gonna ask if you caught the 310 boiler spoiler point. Lmao!! 😂😂😂 He needs to take his own advice and perpetuate his metaphor of water to his students. He's water n they're all sponges. just hope they don't leak that bad info. LoL. I'm an engineer and during a class similar, My "Instructor" said to all ... "Propane is lighter than atmosphere" 😂😂😂 Then when I nicely disagreed, He called me an idiot! SMH. Actually asked if I wanted to go outside and handle it. 😂😂😂 I told him.." No Sir. I believe one more wack on that skull will probably make you forget everything!" Then I looked at all the others n said.. He'll apologize tomorrow hopefully. LP GAS SINKS. Remember that. Needless to say I Tested, Pre-grad n never went back to that class. Least two of us are paying attention. lol

    • @scotthale5335
      @scotthale5335 Год назад

      I saw your comment on the LLFD N laughed. I was gonna ask if you caught the 310 boiler spoiler point. Lmao!! 😂😂😂 He needs to take his own advice and perpetuate his metaphor of water to his students. He's water n they're all sponges. just hope they don't leak that bad info. LoL. I'm an engineer and during a class similar, My "Instructor" said to all ... "Propane is lighter than atmosphere" 😂😂😂 Then when I nicely disagreed, He called me an idiot! SMH. Actually asked if I wanted to go outside and handle it. 😂😂😂 I told him.." No Sir. I believe one more wack on that skull will probably make you forget everything!" Then I looked at all the others n said.. He'll apologize tomorrow hopefully. LP GAS SINKS. Remember that. Needless to say I Tested, Pre-grad n never went back to that class. Least two of us are paying attention. lol We all make mistakes. The One thing about them is to learn from them. He's actually a pretty good instructor. I'm not hating.. Just laughed at an old memory.