PLC Programming - ControlLogix 1756-ENET ENBT EN2TR EtherNet IP Setup Troubleshooting

Поделиться
HTML-код
  • Опубликовано: 6 сен 2024

Комментарии • 56

  • @ardentdfender4116
    @ardentdfender4116 4 года назад +1

    Very good explanation on configuring the EN2T or the comms module. Really appreciated you showing the dip switch reset. You are very through and you know, that’s very important and appreciated. I learned and still learning the hard way in automations but I came from process operations to automations so I understood the process controls. I started in automations by knowing almost nothing though I knew what a plc and modules all were. But it was hard with no explanation of how anything worked working with a very good Senoir Programmer. I learned slowly over time all on doing old plant upgrades at power plant sites and learning ControlLogix with Studio 5k. I have access to almost every RA software from their toolkit and on my laptop for field stuff. However, knowing and understanding how stuff works and software and the details like your explaining is fundamentally important. Not many places or even RUclips channels really explain RA Software in details or how to really program stuff in clear clarity. In programing engineering it’s important to be clear and understand how to do what or why. Your demonstrating that very well here in these videos. Loved it. These days it’s FactoryTalk Linx Software, Classic still exist

  • @craigquary4017
    @craigquary4017 2 года назад

    Great content and love the excellent detailed instruction for the IP addressing configuration. Thanks for sharing.

  • @captainm5911
    @captainm5911 8 месяцев назад

    Thanks for your detailed explanation. Very much appreciated!

  • @FaisalIqbal-yn7ug
    @FaisalIqbal-yn7ug Год назад

    This guy is a legend. Thanks for all the good work mate.

  • @PLCprogrammer
    @PLCprogrammer 4 года назад +2

    Thank you for the informative video.

  • @ussamasajid8409
    @ussamasajid8409 4 года назад +1

    Your videos are amazing man!
    Pl do a video on firmware updates and related issues as well. :-)

  • @thirushaa
    @thirushaa 4 года назад

    Your videos are awesome , thanks to great teacher.

  • @peternjoroge6218
    @peternjoroge6218 Год назад

    Great job.Nice Explanation.I am looking for a topic on PlantPAx

  • @robertledford7994
    @robertledford7994 Год назад

    Your videos are great! The only advice I would have is to speak slower, and don't click through the process so rapidly.

  • @pratikgiridsy-is4931
    @pratikgiridsy-is4931 3 года назад +1

    thank you so much sir for this perfect teaching.

    • @SolisPLC
      @SolisPLC  2 года назад

      You're very welcome!

  • @jgomez7535
    @jgomez7535 2 месяца назад

    Great stuff

  • @Noxwill-lliwxoN
    @Noxwill-lliwxoN 3 года назад +1

    Yeah! Thx You! Very Good information

    • @SolisPLC
      @SolisPLC  3 года назад

      You're welcome! We're glad you found it helpful.

  • @nealneethling7040
    @nealneethling7040 2 года назад +1

    Thank you my dude you helped me alot

    • @SolisPLC
      @SolisPLC  2 года назад

      You're welcome Neal!

  • @xMini-_-Licx
    @xMini-_-Licx 4 месяца назад

    Hello, a noob question, so this method you are doing is changing the Public IP address (Plant) correct? Or the private IP address (Machine)? Either way, thanks so much!

  • @user-bc9xl7dg5k
    @user-bc9xl7dg5k 2 года назад +1

    Thanks for the video .

  • @wssameera5247
    @wssameera5247 Год назад

    Very helpful. Thank you..👍

  • @T---dq2qv
    @T---dq2qv 2 месяца назад

    oh , can i set 256 to set the enthernet ip of this module , instead of the same you 000 ? this is because 256 is out of range the fist box 001-254 ?

  • @lastnameavailableok
    @lastnameavailableok 3 года назад +1

    excellent

  • @dhavalpatel7289
    @dhavalpatel7289 Год назад

    🙏 🙏 🙏 thank you very much sir

  • @suriyat8773
    @suriyat8773 Год назад

    PLC AB thank you

  • @denischiasson7529
    @denischiasson7529 3 года назад +1

    What is the main difference between the EN2T and the EN2TR? I know it has an embedded switch on the EN2TR, and I believe that it has two separate IP addresses are available, Thanks for the video - good content!

    • @SolisPLC
      @SolisPLC  3 года назад

      There are 2 main items: 1. The 2 IP capability as you pointed out. 2. The ability to use DLR (Device Level Ring) which allows for "more reliable" networking of field devices by creating a loop from two points of connections. DLR is good in certain cases and I've seen good implementations of it in the field.
      My advice is to always purchase the EN2TR version unless there's a significant cost increase of one over the other.

  • @azeemahammed8646
    @azeemahammed8646 3 года назад

    Could do you make videos on the Serco communication module like this?
    if possible include a kinetics drive as well?

  • @madhusudhan8932
    @madhusudhan8932 5 месяцев назад

    In settings 000 is not taking un protected. Change switch settings coming

  • @UmeshKumar-wt2yo
    @UmeshKumar-wt2yo Год назад

    Good Content..What is the reason only if PLC is not reachable from scada server although the same is reachable to all???Can you please share your brief checklist on this issue?

    • @SolisPLC
      @SolisPLC  Год назад

      It's either network configuration or PLC / SCADA configuration. I'd probably start with the one that isn't accessible by other devices and see how it's configured, if the physical connection is correct, try to connect it to a single other device, etc.

  • @typeer
    @typeer 2 года назад

    thanks for this

  • @user-td5bw9rt2g
    @user-td5bw9rt2g 4 года назад +1

    I think you could this much with out factory reset with switches, and something was wrong after disabling with bootp rslinx must show you static.

    • @SolisPLC
      @SolisPLC  4 года назад +1

      You are right, but I had someone email me about an ENET card that doesn't have a display. I wanted to demonstrate that the factory reset is an option in that case. BOOTP always had many problems from my experience. Things aren't always showing the way they should. That being said, I've always followed the same steps and things do work out. It's a matter of going through it a few times.

  • @channelsaayana4780
    @channelsaayana4780 Год назад

    👍

  • @mattraymond2935
    @mattraymond2935 4 года назад +1

    THANKS can you do setting up word communication between PLCs?

    • @SolisPLC
      @SolisPLC  4 года назад

      What do you mean by "word communication"? Do you mean passing strings?

    • @mattraymond2935
      @mattraymond2935 4 года назад

      @@SolisPLC yes

  • @nutankumardharsandia1398
    @nutankumardharsandia1398 3 года назад

    Can you pls share how to connect absolute encoder to plc video

  • @rosendolopez2014
    @rosendolopez2014 4 года назад

    Hi Solis PLC, our factory recently got a new Internet setup my Ethernet/IP card on my Chassis is showing a ip of 192.168.1.xx but our new ethernet ip address is 192.168.201.xx what is the best way to change this so i can communicate with my Logix 5555?

    • @SolisPLC
      @SolisPLC  4 года назад

      You can change it via RSLinx and that would be my recommended option. Simply add the current IP of the card into the IO tree, go into properties, and change it in the network tab.

  • @kolyangod2715
    @kolyangod2715 4 года назад +1

    Hello! do you have any lessons in Russian? Thx

    • @SolisPLC
      @SolisPLC  4 года назад +1

      I don't, but I'd love to have them translated.

    • @kolyangod2715
      @kolyangod2715 4 года назад

      That would be great!!!
      P.S. Thank you for your lessons!! They're great!

  • @bendylee860
    @bendylee860 4 года назад

    Can I have this software? Thanks

    • @SolisPLC
      @SolisPLC  4 года назад +1

      We can issue a quote.

    • @bendylee860
      @bendylee860 4 года назад

      @@SolisPLC how much?

    • @SolisPLC
      @SolisPLC  4 года назад

      @@bendylee860 It's around $8,000 USD / year license for Studio 5000.

  • @mikegould1041
    @mikegould1041 4 года назад

    test