Daikin VRV3 | Emergency setting | CU slave 2(error E5)

Поделиться
HTML-код
  • Опубликовано: 29 окт 2024

Комментарии • 131

  • @birin.6884
    @birin.6884 2 года назад +1

    The best videos of photography and explanation

    • @BonMj
      @BonMj  2 года назад

      Thanks 🙏🙏

  • @sherwinmirando3766
    @sherwinmirando3766 3 года назад +3

    Thanks for sharing your knowledge Sir..

    • @BonMj
      @BonMj  3 года назад

      Thanks for watching my video

  • @juanmarte259
    @juanmarte259 2 года назад +1

    Thank you my teacher

    • @BonMj
      @BonMj  2 года назад

      Thanks

  • @mohammadahmadi7380
    @mohammadahmadi7380 Год назад +1

    Mr Bon well done mate .I like you channel .

  • @Whoareyouuuu756
    @Whoareyouuuu756 2 года назад +2

    Did you code out on the master or slave ?

  • @PaullequinTv
    @PaullequinTv 3 года назад +3

    thanks for sharing your knowledge about the troubleshooting i learn a lot from your channel brother keep up the good work new friend here 🙏👏🙏👏🙏👏🙏👏🙏👏

    • @BonMj
      @BonMj  3 года назад

      Thanks bro

  • @JuanTodoli
    @JuanTodoli 3 года назад +2

    Is the bypassing unit (or compressor) modes purpose to allow swapping the compressor (or other repairs) without having to shut down all the system (all units)?

  • @michaelerestain4634
    @michaelerestain4634 3 года назад +1

    What is CU Slave 2 sir,and thanks for sharing knowledge,god bless you

    • @BonMj
      @BonMj  3 года назад +5

      This is multi outdoor unit.
      Mean got 3 condensing unit.
      Main,slave1,slave2.

  • @PaullequinTv
    @PaullequinTv 3 года назад +1

    boss i have a doubt regarding the multiple outdoor unit like for example if the remote control shows an error where should we need to troubleshoot the master unit not for slave am i right?

  • @arnelvlog
    @arnelvlog 2 года назад +1

    wow nice video im also A/C isntallation in saudi arabia but not to isntall VRF and VRV

    • @BonMj
      @BonMj  2 года назад

      👍👍

  • @toufikmatib9855
    @toufikmatib9855 Год назад +1

    Hello Boj thx for sharing ,please how do I know a slave1 compressor on multisystem is bypassed or not?
    Many thanks

  • @jagdishmauryamaurya6783
    @jagdishmauryamaurya6783 3 года назад +1

    Very nice,thank you

    • @BonMj
      @BonMj  3 года назад

      Thanks

  • @mohammadsobuj7027
    @mohammadsobuj7027 2 года назад +1

    Thank you .

  • @ARSHADkHAN-sd8zb
    @ARSHADkHAN-sd8zb 3 года назад +1

    Thanks alot Sir usefull trening

    • @BonMj
      @BonMj  3 года назад

      Thanks

  • @AsimKhan-pr6rh
    @AsimKhan-pr6rh Год назад +2

    V nice ❤❤❤

  • @sathiskumar7358
    @sathiskumar7358 2 года назад +2

    Hi Sir,
    Thanks for sharing your knowledge, i would like to your upload vrv all troubleshooting videos..I'm also increased my skills.
    I have one doubt if slave unit CU failure will do emergency setting master unit? Or slave unit?. Thanks!

    • @BonMj
      @BonMj  2 года назад +1

      All setting at master unit

    • @sathiskumar7358
      @sathiskumar7358 2 года назад +1

      @@BonMj Thanks you Sir

  • @jairam425
    @jairam425 3 года назад +1

    Without remove communication cable do this settings ?

  • @muthusamy228
    @muthusamy228 Год назад +2

    mr bon this one compressor fault or pcb also

    • @BonMj
      @BonMj  Год назад +1

      Pcb.
      Normally will recommend replace inverter compressor too.

  • @16valve64
    @16valve64 3 года назад +1

    Bon.what is the good value of coil thermistor and air sensor of Daikin split unit.. thanks a lot bon

    • @BonMj
      @BonMj  3 года назад

      Thermistor reading?

  • @selvarasumanikandan7646
    @selvarasumanikandan7646 2 года назад +1

    Thanks

    • @BonMj
      @BonMj  2 года назад

      Thanks

  • @laxmanbhaloriya729
    @laxmanbhaloriya729 2 года назад +1

    Thanx sir

    • @BonMj
      @BonMj  2 года назад

      Thanks

  • @glennbesin27
    @glennbesin27 Год назад +1

    I have question sir. Its same set up on emergency bypass setting model# RXQ16TAYM?..
    Pls send me how to set emergency baypass sir. Thank u..

    • @BonMj
      @BonMj  Год назад

      What you want to by pass compressor or cu

  • @gorleeswararao4743
    @gorleeswararao4743 Год назад +1

    Hi Bon Mj can you explain to how to do vrv3 inverter compressor emegency setting

    • @BonMj
      @BonMj  Год назад

      Sigle cu or multi cu?

  • @albertarmecin6671
    @albertarmecin6671 3 года назад +1

    Mr. Bon Mj thank you for sharing your skills and knowledge and some advice
    Can i ask?
    I incounter U4 and U2 of the VRV3 Multi split 1accu 5fcu
    What is your advice sir😢

    • @BonMj
      @BonMj  3 года назад

      Do you check the income voltage and DC voltage (550V)DC

    • @albertarmecin6671
      @albertarmecin6671 3 года назад +1

      @@BonMj yes sir and its only 380 volts
      But in the accu the lead light h2p ang the last led beside h7p is blinking also

    • @albertarmecin6671
      @albertarmecin6671 3 года назад +1

      @@BonMj thank you for your help sir im in Cebu

    • @BonMj
      @BonMj  3 года назад

      @@albertarmecin6671 inverter board 380VDC?

    • @BonMj
      @BonMj  3 года назад

      @@albertarmecin6671 h7p blinking ..mean this is CU slave 1.
      H2P Led on mean got error code.
      Long press Reset button the clear the history.

  • @harta9aaat779
    @harta9aaat779 3 года назад +1

    Mr bon thank you first
    Can i ask you , how to making a demarrage test for the compresseur in main unit and slave 1 , and 2 , inverter and standard .vrv 3

    • @BonMj
      @BonMj  3 года назад +1

      Check the running amps

  • @riquesalvador
    @riquesalvador 3 года назад +1

    Is that the same procedure when you wil bypass other slave,ex. Salave 3,same procedure?when you fix the problem of the unit ,what is the procedure to return in normal operation

    • @BonMj
      @BonMj  3 года назад +5

      We call it by pass,the correct word is ermergency settings.
      Procedure is same.
      Master unit 38times
      Slave 1 39 times
      Slave 2 40 times.
      Same procedure to deactivate

    • @riquesalvador
      @riquesalvador 3 года назад +1

      @@BonMj tnx very much for the knowledge its a big help for me ill sahre your vids to my page rgarding hvac also tnx God bless

    • @maxtv1546
      @maxtv1546 2 года назад

      @@BonMj can i have your WhatsApp number

    • @Air_Conditioners_
      @Air_Conditioners_ 3 месяца назад

      @@BonMj thank you so much✊🏻

  • @Ahmadimranan
    @Ahmadimranan 3 месяца назад +1

    Hi mr Bon daikin vrv 3 error code U0 what should I do..is there not enough gas? please help me

    • @BonMj
      @BonMj  3 месяца назад +1

      Please check pressure

  • @SeinWinHtun105
    @SeinWinHtun105 10 месяцев назад +1

    How to recharge emergency setting to normal setting.

  • @langtumientay7720
    @langtumientay7720 3 года назад +1

    Is there a no-compressor mode?

    • @BonMj
      @BonMj  3 года назад

      What you mean?

  • @karaors8970
    @karaors8970 3 года назад +1

    👍🤳🇹🇷🛠️

    • @BonMj
      @BonMj  3 года назад

      Thanks

  • @iniyakumariniyakumar1446
    @iniyakumariniyakumar1446 2 года назад +1

    Hi sir if i replace the compressor what I can do the normal sistem

    • @BonMj
      @BonMj  2 года назад

      Just replace the compressor charging gas test run

    • @iniyakumariniyakumar1446
      @iniyakumariniyakumar1446 2 года назад +1

      Thanks sir advice for everybody 🙏

  • @riquesalvador
    @riquesalvador 3 года назад +1

    is VRV 2 & VRV 3 has the same pcb bard ,hat are the difference,

    • @BonMj
      @BonMj  3 года назад

      Different

    • @riquesalvador
      @riquesalvador 3 года назад +1

      @@BonMj sir how about the procedure of emrgency setting of vrv 2 & vrv3 is it the same

    • @kcomfortsystemshvac7060
      @kcomfortsystemshvac7060 3 года назад

      @@riquesalvador check in Google’s,,,,,😉

  • @abbasykq8211
    @abbasykq8211 2 года назад +1

    Hello mr.
    I have h2p light flashing
    And h3p light on
    In vrv daikin 3
    Can you help me please

    • @BonMj
      @BonMj  2 года назад

      Try press off power supply and on back.
      Press return button more than 10second and wait till h2p light off

  • @langtumientay7720
    @langtumientay7720 3 года назад +1

    Make friends to share experiences

  • @hvacandvrvspecialvedoindus7891
    @hvacandvrvspecialvedoindus7891 2 года назад +1

    Bon sar how to indoor bypass

  • @riquesalvador
    @riquesalvador 3 года назад +1

    How about setting to bypass if 1 indoor is defective,tnx in advance new fren here

    • @BonMj
      @BonMj  3 года назад +1

      off the indoor unit.and off the outdoor unit too,on back the outdoor power supply (H2P light blinking)and press reset more than 5 second.till outdoor
      H2P light off.(H3P light on)

    • @riquesalvador
      @riquesalvador 3 года назад +1

      @@BonMj ok sir thats all & it should run the unit?ok sir tnx ill try it,the unit is vrv2

  • @LeoTechrac
    @LeoTechrac Год назад +1

    Hi, I have the same error e5, all compressor is not working, how to reset e5 error?

    • @BonMj
      @BonMj  Год назад

      Check inverter Pcb and inverter compressor

    • @LeoTechrac
      @LeoTechrac Год назад +1

      I checked with my inverter checker and found pcb is okay and inverter compressor failed in both master and slave.

    • @BonMj
      @BonMj  Год назад +1

      @@LeoTechrac u need to replace both inverter compressor,better replace together pcb

    • @LeoTechrac
      @LeoTechrac Год назад

      Other tech was replaced all of them less than a year and it’s failed again. Do you think there’s a other problem that causing compressor become damaged? Thanks

  • @kentbalolong1260
    @kentbalolong1260 2 года назад +1

    sir bon i have encounter the error code E5-02..in VRV IV model no. RXQ14TTL..can you please help me how to solve this problem..thanks and god bless...

    • @BonMj
      @BonMj  2 года назад

      Check inverter pcb and inverter compressor

  • @hozaifakhan6893
    @hozaifakhan6893 2 года назад +1

    Inverter compressor over current

  • @zaiihong9342
    @zaiihong9342 2 года назад +1

    bro H3P got light only what problem ?

    • @BonMj
      @BonMj  2 года назад

      Vrv3 got light is normal.
      Master CU

  • @peramaraj2763
    @peramaraj2763 2 года назад +1

    Hi sir how to find inverter compressor and standard compressor then how to find faulty inverter compressor

    • @BonMj
      @BonMj  2 года назад

      The compressor connect to inverter pcb is inverter compressor.
      The compressor connect to magnetic contactor is standard compressor.

    • @peramaraj2763
      @peramaraj2763 2 года назад +1

      @@BonMj super sir thank you so much

    • @peramaraj2763
      @peramaraj2763 Год назад

      How to find standard compressor -1 & 2 ?

  • @ManojKumar-zu2yz
    @ManojKumar-zu2yz Год назад +1

    Sir help me daikin vrv3 error code p4 modal rxyq12pry6

  • @selvarasumanikandan7646
    @selvarasumanikandan7646 2 года назад +1

    RXQ12 PCB BOARD H2P AND H3P LED UP OUT DOOR UNIT NOT RUN .HIW DO REST AND RUN one vedio

    • @BonMj
      @BonMj  2 года назад

      Press reset button more than 5second.

  • @alamroushan9351
    @alamroushan9351 Год назад +1

    What is emergency settings sir

  • @mohdmaqsoodshaikh5234
    @mohdmaqsoodshaikh5234 2 года назад +1

    Master unit inverter emargency settings sir pls help code

    • @BonMj
      @BonMj  2 года назад

      Master unit cant by pass inverter compressor. Only can by pass master unit

  • @tunlin3211
    @tunlin3211 3 года назад +1

    I want learn more

    • @BonMj
      @BonMj  3 года назад

      Thanks

  • @hvacandvrvspecialvedoindus7891
    @hvacandvrvspecialvedoindus7891 2 года назад +1

    Selev 2 bypass this setting only mastar run

  • @janshaw5472
    @janshaw5472 3 года назад +1

    bypass cu 2 means CU 2 not use ?

    • @BonMj
      @BonMj  3 года назад

      Yes.temporary cu2 not in use.
      Can set back after repair.

    • @BonMj
      @BonMj  3 года назад +2

      Help me share my video.thanks

    • @janshaw5472
      @janshaw5472 3 года назад +1

      @@BonMj Yes master

    • @janshaw5472
      @janshaw5472 3 года назад +1

      @@BonMj 师傅这台E5是要换compressor 么?😀

    • @BonMj
      @BonMj  3 года назад

      @@janshaw5472 是的。

  • @mohammedrezaulkarim1702
    @mohammedrezaulkarim1702 2 месяца назад

    What is problem? And Solution???
    Compressor NG?
    Because same problem i face in Bangladesh this ERROR E5..
    Please give replay what i do.
    Compressor take 12.11Amp
    Than come 4.2, & 1.9 A then stop.
    After 3 time pcb commamd E5 error.in remote.
    Thanks

    • @mohammedrezaulkarim1702
      @mohammedrezaulkarim1702 2 месяца назад

      Please sir give a solution.

    • @BonMj
      @BonMj  2 месяца назад

      Check inverter pcb

    • @BonMj
      @BonMj  2 месяца назад

      Or inverter compressor

    • @mohammedrezaulkarim1702
      @mohammedrezaulkarim1702 2 месяца назад

      ​@@BonMj
      Sir, i check inverter pcb, means igbt pcb is ok.
      Because i install in slave 01 compress, and run Compressor is ok.

    • @mohammedrezaulkarim1702
      @mohammedrezaulkarim1702 2 месяца назад

      ​@@BonMj
      Sir, thanks for replay
      Sir i check inverter pcb means, IGBT pcb
      Install in mno. 01 slave
      Then Compressor is run smoothly.
      So pcb is ok.
      Now what can is done?
      # out door fan also run.
      # when Compressor start amp comp 12.11Amp that time solenoid valve
      1 is Anam other 2 is off.

  • @play3ro69
    @play3ro69 2 года назад +2

    Daikin is the worse system to be installed in an apartment complex.