X0 X2 X3 x4 like that are high speed inout but that sint ahve to use for encoder , that input you Hage to singed for example for X0 counter C235 u have to use to read high speed input puse
Phase A and B will come together And it's ready made register C251 for both Phase Aand B And also for that Register and Memory bit which u have to activate
Thank you Configuration of PLC ?? Encoder how to configure in PLC and what types of counter we have to take that we have explained if still you need than let us know , sure we will explain. For more details you can whats app us +91 9664444394
@@praveenkumarlk8527 Channel we don't need to sign for counter There are special register memory and register which we have to on or move k1 or k2 We have already clearly shown in this video Channel assign in analog module we do Like for 4 to 20ma or 0 to 10 volt
Same way at other high speed input of PLC Suppose 1st Encoder at X0 and X1 then 2nd Encoder at X2 and X3 ( Here we are taking Two Phase of Encoder meand A and B if you want u can take single phase only means only A Phase) Hope doubt clear . Thank you
please sir can you explain why did you use (M1264) and M(1273) ??!! or more detail or explanation about the double phase code .. thx for the video it was very helpful
Same what we have written for X17 All inputs are independent It's depend machine to machine and programming For example one engineer or at one machine X0 - as start push button Some one taken X0 - As emergency Some one X0 as auto manual switch Hope your doubts clear At ur machine what they have taken how can we say ??? That input from where it's coming and where going u can easily find out its not big deal . So better have look this matter with person electrician who have some basic knowledge of PLC
@@sanatechautomation279 incremental A B second how to connect?? C251 Works with x0 x1 C252 and C254 also x0 x1. How to connect a second incremental encoder.?? 2 phase 2 inputs.
Hardware Connection Means you are talking PLC input Every PLC has high speed puls input In that hou have to connect Like X0 - for A phase X1 - For Phase And as per PLC that associate high speed counter you have to take Like C235 for single phase C251 for Double phase Example I have given for Delta PLC For more detail what's app please 9664444394
Encoder ki apni koi speed nahi hoti hai .. Kuen wo khud nahi chaltaa kisi ke saath chaltaa hai ... jaise Four wheeler tyre ki apni koi speed nahi hoti hai .... hope doubts clear ... Haan encoder ek rotation mien kitnaa puls degaa wo important hotaa bai jisko PPR kahte hain ... Puls per rotations .
Alam sir
Keep uploading and teaching us with your valuable and experienced technical
Thanks alot
sure We will do .....
Explained in very detail and helpful for for start up engineer . Keep it up
Thanks for share
Keep uploading sir
Cool background picture on your laptop
Thank you
Good job sir
Thank you
Thank you, its helpful
Most welcome
Your video was very interesting.
Thanks a lot sir
For your valuable and appreciated comments .
Very thanks Sir
Welcome
Excellent sir
Thanks a lot sir
@@sanatechautomation279 well come sirjiii 🙏🙏
Excellent
very nice explanation
Thanks a lot
Superb 💐
Thanks for your valuable feedback sir
Sir input m1000 use Or input is 0.0 how to this work
Sorry dis not understand
M1000 is always on bit
X0 X2 X3 x4 like that are high speed inout but that sint ahve to use for encoder , that input you Hage to singed for example for X0 counter C235 u have to use to read high speed input puse
well explained !
Thank you
Leveling or printing ki same speed ka kya dekhna hai
Thanks brother
Welcome
is it possible to rotate servo at multiturn rotation in one shot?eg.if i give 1 digital signal that is hi then it rotate 5 round.
What's us 91 9664444394
Where did you assign Phase A to Input X0 and phase B to input X1 on PLC ??
Phase A and B will come together
And it's ready made register
C251 for both Phase Aand B
And also for that Register and Memory bit which u have to activate
Sir, i have to rotate Stepper motor with encoder and delta plc SS2, is it possible to run on high speed
Better use DVP12SA2T
Thanks sir
Welcome
Dear sir...ur video is very much informative......plz make video on linear position measurement using encoder...
Thanks a lot for your valuable feedbak.
Sure we will make .
clear explanation sir, please explain configuration on plc.
Thank you
Configuration of PLC ??
Encoder how to configure in PLC and what types of counter we have to take that we have explained if still you need than let us know , sure we will explain.
For more details you can whats app us
+91 9664444394
@@sanatechautomation279 hi sir,
somewhere we need assign single channel in plc , where we need to assign..?
@@praveenkumarlk8527
Channel we don't need to sign for counter
There are special register memory and register which we have to on or move k1 or k2
We have already clearly shown in this video
Channel assign in analog module we do
Like for 4 to 20ma or 0 to 10 volt
thanks 👍👍👍👍
sir model no off comm.cable used?
Which communication cable ??
Can you what's app us
For more details
9664444394
@@sanatechautomation279 country code?
@@sanatechautomation279 plc to pc and if u know suitable comm cable for plc to hmi(dopbq103)
Call us
Or whats app
+91 9664444394
how to connect if use more than 1 encoder, 1 phase
Same way at other high speed input of PLC Suppose 1st Encoder at X0 and X1 then 2nd Encoder at X2 and X3 ( Here we are taking Two Phase of Encoder meand A and B if you want u can take single phase only means only A Phase) Hope doubt clear . Thank you
Hi bro please post more videos related from delta plc
Okay sir
Thanks for your valuable feedback
Sure we will post more
I need this could you able to supply angle encoder 360 degree
Yes sir
We have in stock
Just what's app on this number
+91 9664444394
Yes sir
You can call or whats app or mail
sanatechautomation@gmail.com
🥰🥰🥰🥰
How to connect with sensor
please sir can you explain why did you use (M1264) and M(1273) ??!!
or more detail or explanation about the double phase code ..
thx for the video it was very helpful
Please what's app
91 9664444394
Thanks a lot for feedback
HI i have a project and some help even can pay for your help
Yes sir
Please contact with us on +91 9664444394
Hai sir delta DVP28SV software name....
WPL Soft
Dear sir what is X17 - cutter limit
X17 is like other input
Programmer can assign or take that input as per his wiring like cutter input
Pressure input
Start
Stop
Emergency as per need
Dear sir, and what is X0 work
Same what we have written for X17
All inputs are independent
It's depend machine to machine and programming
For example one engineer or at one machine X0 - as start push button
Some one taken X0 - As emergency
Some one X0 as auto manual switch
Hope your doubts clear
At ur machine what they have taken how can we say ???
That input from where it's coming and where going u can easily find out its not big deal .
So better have look this matter with person electrician who have some basic knowledge of PLC
Same things we have reply on what's app also
@@sanatechautomation279 thanks sir
Labelling and printing and Inko truck ki speed Kitni honi chahie
Sorry
We won't get your question
Can you what's app us 91 9664444394
Or kindly ask once again in other words so tat we can help you
Thank you
how to connect two encoders?
Easily can connect two encoder same process as for one encoder
@@sanatechautomation279
incremental A B
second how to connect??
C251 Works with x0 x1 C252 and C254 also x0 x1.
How to connect a second incremental encoder.?? 2 phase 2 inputs.
@@sanatechautomation279
for sure ( C235 M1235)
🙂
Hello, how many PPR is your encoder?
1000 PPR
What is the 3 wire in plc? the orange, black and blue.
Supply
24 Volt 0volt and Earthing
What's app for more query
9664444394
Good explain...
But your video is not stabel hope yo correct it soon..
Where are hardware connection? Plz tell the hardware detail I want to connect incremental encoder to fuji micrex f70 series plc
Hardware Connection
Means you are talking PLC input
Every PLC has high speed puls input
In that hou have to connect
Like X0 - for A phase
X1 - For Phase
And as per PLC that associate high speed counter you have to take Like C235 for single phase C251 for Double phase
Example I have given for Delta PLC
For more detail what's app please
9664444394
The wire connected to plc input s/s,x0,x1?
S/s means PLC Common
X0
X1
Means input
Supposed you are connecting 24Dc in as than
X0
X1
Should be 0 Volt DC
Never give AC volt on this
For more details what's app us
9664444394
Give me a job for delta PLC programming and I am a experience person camplate panel warning
Sir send your resume at
hr@sanatechautomation.com
If there will be any position vacant than team will contact with you
Thank you
Encoder ki speed
Encoder ki apni koi speed nahi hoti hai .. Kuen wo khud nahi chaltaa kisi ke saath chaltaa hai ... jaise Four wheeler tyre ki apni koi speed nahi hoti hai .... hope doubts clear ... Haan encoder ek rotation mien kitnaa puls degaa wo important hotaa bai jisko PPR kahte hain ... Puls per rotations .
To Dada sink connection hoga
Yes
Sar Hindi me bolye
Noted
Okay dear next time Hind mien bolungaa .
Excellent sir
Thank you