#68: Isolation Transformer Warning!

Поделиться
HTML-код
  • Опубликовано: 19 ноя 2024

Комментарии • 45

  • @tiggywinkle1000
    @tiggywinkle1000 3 года назад +3

    You correct the misapprehension that some techs have, who say that they do not need an isolation transformer when working on a valve guitar amplifier, because it has it's own transformer in its power supply and is therefore 'already isolated'. They fail to understand that the secondary of the PSU transformer is grounded, and thus not isolated from the mains.
    They need to watch your well-informed video to put them right.

  • @vincentnonnenmacher9352
    @vincentnonnenmacher9352 3 года назад +4

    Probably by far the BEST video I ever see on isolation transformers and why/how/why not some are wired that way on the secondary side, thanks a lot :-)

    • @w0qe
      @w0qe  3 года назад +1

      Vincent, glad you enjoyed the video.
      Larry, W0QE

    • @franzliszt3195
      @franzliszt3195 2 года назад +1

      @@w0qe Bravo. This is why medical isolation transformers are not 'true' isolation transformers; I've been wondering about that for awhile.

  • @windward2818
    @windward2818 2 года назад +3

    Most of my experience is in using Toroidal Medical Transformers for instrumentation and test. I think in general the Medical Transformers provide additional features not found in a similar sized (VA) non-medical grade transformer at the expense of being slightly larger in size.
    Common Medical Transformer upgrades:
    Low AC leakage design which includes a shield and shield wire between primary and secondary.
    Higher insulation temperature rating to Class F.
    Built in thermal breaker.
    Structural regidity by having a potted core.
    Tested to the higher standard agency rating (several agency standards worldwide). Also, if a custom higher performance internal company rating is needed for better performance (for example extended Hi Pot) the base design can usually be modified to meet it at extra cost.
    Large Toroidal Transfomers, approximately 500VA and larger at 120VAC, will need a surge current (magnetization current) limit circuit.
    It is hard to know what you describe as general purpose. To me general purpose would be to isolate line power and ground, then I could wire a ground connection if needed.
    On the output you could use a heavy duty hospital grade receptacle with isolated ground then you could establish a ground connection (if needed) to a grounding point without connection to chassis (receptacle strapping ground connection).

  • @glenmartin2437
    @glenmartin2437 2 года назад

    Thank you.
    This helped me to understand the current flow magnitudes.

  • @williamburling3229
    @williamburling3229 3 года назад +1

    I love this video. You made me think. I wish I had your mind. thank you so much for sharing. Very Grateful

    • @w0qe
      @w0qe  3 года назад

      Thanks!
      Larry, W0QE

  • @mikeg3660
    @mikeg3660 2 года назад +1

    Excellent safety and instructive video….

    • @w0qe
      @w0qe  2 года назад

      Thanks!
      Larry

  • @drmindbender8616
    @drmindbender8616 Месяц назад

    In the US have you had to upgrade the trips in the consumer unit recent upgrades in the UK and Europe called amendments to the IEE wiring regulations reference DC blocking ??

  • @nonsuch
    @nonsuch Год назад +2

    It doesn't have a problem or a "dark side". It's a "Medical" Isolation Transformer, not a "Lab" Isolation Transformer. It's exactly how it's supposed to be. Obviously, it's easily converted but, to say it has a dark side is incorrect.

    • @w0qe
      @w0qe  Год назад +1

      You are correct that it was built exactly as it was supposed to be. I would be willing to bet that there are many of these surplus "Medical" Isolation transformers that many people have picked up believing that that they are "Lab" types.

  • @KD0CAC
    @KD0CAC 6 лет назад +1

    I have one that looks similar , and have caught what others have said " do not use to test house-hold AC circuits " .
    And wondered , hay its spouse to be a isolation transformer , what the hay ?
    I assume [ and we now that can get us in trouble ] they defeat the isolation in isolation transformer because of lawyers / insurance .
    Seems to get commitments on use scopes for AC line , is only spouse to be done with expensive probes - high voltage differential probes .
    Thanks again

  • @VictorSilva-rq4kz
    @VictorSilva-rq4kz 2 года назад +1

    Thank you, I learned something today.

  • @waynemcmurtry
    @waynemcmurtry 3 года назад

    Thank You so much. I have VFD mini split heat pump on a concession trailer. I have to plug the trailer into a GFCI sometimes.
    Do you think this would stop the harmonic back feed from the heat pump?

  • @w8lvradio
    @w8lvradio 6 лет назад +1

    I just wish that there were some reasonably priced differential probes on the market, to put the whole mess to rest. As I don't see any, and those on the market are not 1X or 10X, always 50X or 100 X or some such, I'm guessing that they would somehow load up the circuit at the lower levels. An explanation of Differential (isolated) probes as opposed to differential mode on the scope selection itself would make a good lecture. There's just too much USB and switching power supply stuff out there and such to bite your butt these days. I Don't recall a lot of scope dead shorts back in High School Vocational Electronics Class in the late '70's, when we were probing relatively high voltage television chassis (NOT the super high tension stuff in the metal "cage" of course!) 73 DE W8LV Bill

    • @w0qe
      @w0qe  6 лет назад +5

      Differential probes make it easy to do measurements but they don't reduce the shock risk to you.
      Larry

  • @williamburling3229
    @williamburling3229 3 года назад

    Dear Larry
    First:
    am not coming from a confrontational point of view. I am sincerely trying to understand
    Lots of things. Let me convey how I am thinking. Then I am hoping you will correct my thinking.
    Topic:
    Leaving the outlet ground connected to the supply ground in a electronic technicians isolation transformer. (Secondary transformer winding iis NOT connected to source ground).
    Point one:
    Your video does an awesome job of explaining why leaving the ground in the isolation transformer outlet impActs the output of the isolation transformer to a minimal degree. Ie: touching either side of
    Transformer secondary to ground does not change the secondary voltage value.
    Point I would like to introduce:
    Lets now connect the output of our electronic technicians isolation transformer to an imaginary circuit.
    In which the ground of the isolation transformer now is attached to the imaginary circuit chassis.
    Allow me to make one more assumption: the circuit designer of the imaginary circuit
    Connects various points in the circuit to ground.
    Now lets attach the scope probe alligstor clip to any circuit element (specificallya side of that element electrically furthest from the chassis
    Now the model I use to predict circuit behavior with grounds involved is to imagine any two grounds connected by a low resistance wire.
    Thus if one side of a circuit element is touching chassis ground and the other side to scope probe ground
    I imagine a wire across that circuit element. Thus in my mind the imaginary “shorting” wire would carry the current defined by the circuit. The “grounding” per se is not relevant. It is the short circuit that is relevant.
    So the concept I am trying to convey is that if a circuit has only one ground, essentially it never ever caries current. But if two or more grounds exist, then a short is likely
    Given that principle (which may be incorrect), then it might be prudent to remove the isolation outlet ground thus making the scope alligator ground the only ground in the imaginary circuit
    Please correct me if I have failed to grasp important concepts. I don’t care if I am “wrong”,
    I just want to understand.

    • @w0qe
      @w0qe  3 года назад +1

      William,
      Replace the isolation transformer with a battery that connects to some circuit with no connections made to earth ground. Then connect 2 points of the circuit (which have a potential difference between them) to earth ground. Of course current flows and the potential difference between the 2 points will be nearly zero is the wire size is large enough. These 2 wires will have a current flowing in them depending on the circuit. However this current will be the same as if a single wire connected those 2 same points together on the circuit with no connection to earth ground. This is not really current flowing to ground. The same thing exists for the isolation transformer.
      Larry, W0QE

  • @ambersmith6517
    @ambersmith6517 4 года назад +1

    Which is better when choosing a toroid Transformer taller or wider?
    I build home made low frequency pure sine wave power inverters
    I stacked 4 cores to make a larger transformer my idle current on this odd tall Transformer on the 48volt battery side is .29 just a little over a quarter of a amp
    The stacked 4 core tall inverter is only a 2000 watt inverter but I have seen over 30 amps on the 120 volt side when starting big loads while running hair dryer
    Taller just seems better than wider
    I have wound many normal cores since the tall stacked one
    None of the Finnish inverters have had that low of idle current
    The highest so far has been .44 that is getting close to half of a amp
    2000 watt is smallest inverter I have ever made all others are above 5000 watts
    Stacked core one was around 30 pounds
    The biggest Transformer so far is over 70 pounds
    The largest wattage inverter I have built is 10000 watts
    All inverters have chokes on one leg of low side of Transformer I also wind the chokes myself
    My point is I have to may variables to know for sure just a hunch that taller is better
    I thought you may know or be curious enuff to find out if I can help in any way please let me know
    Have a blessed day

    • @w0qe
      @w0qe  4 года назад +1

      Amber,
      Have you seen my video #65 at ruclips.net/video/Yh7_XuHqbRI/видео.html where I discussed the relationship between core area, mean path length, inductance, and flux level? Also look at video #64 and #66 which also relate to toroids. I believe these videos will answer your questions.
      Larry, W0QE

  • @w8lvradio
    @w8lvradio 6 лет назад

    Oh My Goodness...Thanks! Man, I was looking at that circuit, and PERPLEXED at seeing C1 and C2! ;-)

  • @fishyrider3528
    @fishyrider3528 6 лет назад +1

    This was great. Thank you.

  • @w8lvradio
    @w8lvradio 6 лет назад

    What about C1 and C2? Would a failure in either of these lead to a short, and should they be removed? DE W8LV Bill

    • @w0qe
      @w0qe  6 лет назад +2

      William,
      C1 and C2 were shown in my schematic representation of the isolation transformer but do not represent actual components. They are due to the proximity of the 2 windings and the insulation between them which is a capacitance. Between the windings is a Faraday shield which is connected to green wire ground. This shield is an open turn or maybe 1 1/2 turns (to completely isolate the windings) made of a sheet of copper or aluminum. If the transformer suffered an insulation failure (which would be like a short in C1 and C2 in my simulation) the user would be at a risk of shock but the Faraday shield would protect the user by blowing the fuse. Does this help?
      Larry, W0QE

  • @harry4516
    @harry4516 6 лет назад

    great video, didn't know that there are isolation transformers with a ground-N connection. Just checked my transformer (supplies the pump in the garden pond), but there is no connection, good. Additionally I have installed an isolation monitor, a DOLD IL5880. Do you think this makes it safe in all situations ?

    • @w0qe
      @w0qe  6 лет назад +1

      I believe an isolation monitor is nothing more than a very sensitive GFCI. For a "safe in all situations" you get involved with wanting 2 or more failures to be "not" safe before anything bad can happen. Transformer insulation barriers are in the very unlikely to fail category and the isolation monitor is a check on the transformer isolation. However if you were designing something that needed to be even safer you would want to know if the isolation monitor itself had died which would guarantee if either of the 2 protections had failed you would be alerted.
      Larry

  • @RobB_VK6ES
    @RobB_VK6ES 4 года назад

    Any sense in using a GFCI on the output of the transformer? If so how would you connect it ?

    • @w0qe
      @w0qe  4 года назад +2

      Rob,
      If the isolation transformer is connected so that if you externally connect either of the 2 hot wires to ground and the resulting current flow to ground is below the trip point of a GFCI then the answer is no.
      Larry, W0QE

  • @Maxi_Shubert
    @Maxi_Shubert 3 года назад

    I have a refrigerator connected to the CFGI and its randomly tripping CFGI. Will the isolation transformer help or fix this problem?

    • @w0qe
      @w0qe  3 года назад +3

      Eugene,
      Since the refrigerator randomly trips the GFCI I would believe that there is an intermittent problem in the refrigerator which ultimately could be dangerous. I would not try to fix the tripping with an isolation transformer.
      Larry, W0QE

  • @JhasNo-q4v
    @JhasNo-q4v Год назад

    GAMES TO PLAY...

  • @joea3728
    @joea3728 4 года назад +2

    If you really want to be safe, when using a electronic shop isolation transformer, Use a GFCI on the output side of the transformer. Tie the negative and ground wires of the GFCI together. Do not connect ground to earth ground. Now you have some protection, if there is a ground fault. Basically giving you a virtual ground. You can mount the GFCI in a separate electrical box. connected with the cord, Minus the ground of course. When a fault occurs, The GFCI will trip. Leaving only the negative side hot but since there is no way to get a complete circuit, you are protected. And so is your equipment.

  • @PowderMill
    @PowderMill 3 года назад +2

    My Dad was a dentist with an office in our home. He had literally doubled the size of our home
    to provide for 4 “operatories” . He subsequently opened up a much larger and more advanced office in town.
    That left the home facility vacant and prime for exploration.
    I spent my youth playing experimenter and explorer down in his old office and am still amazed that I survived it
    with only a few minor near-electrocution incidents and a few arc-flash retina burns.
    He had a bunch of isolation xformers throughout the office and that way before the ubiquity of
    GFCI devices in the home or workplace.
    That was back in the 1970’s and I sure wish RUclips videos were available to us to allow
    ACTUAL learning to take place.
    disclaimer = I was referring to “PRE-WOKE” RUclips .. BEFORE they started banning
    political views opposed to the SJW FAR-FAR-FAR LEFT. I’m still waiting for the Tech-Elite
    to start the purge of RF / HAM / Microwave / Communications/ Electronics channels.
    They cannot permit the filthy & unwashed population of the USSA to have access to real knowledge
    that will allow FREE & FAIR communications (OR Elections for that matter)

  • @jaackmcmahon8757
    @jaackmcmahon8757 4 года назад

    How Much is YOUR LIFE Worth? Keeping your test equipment(TE) from being at LETHAL voltages is critical. Seeing how an isolation xfmr. prevents your TE from riding at line voltages really drove home how to prevent a person from getting electrocuted. Possible noisy reading or complete AC line isolation, your choice? Your workbench TE must be safe to keep from giving you the shock of your life or death.

    • @w0qe
      @w0qe  4 года назад +5

      What are you complaining about? Once I took the medical isolation transformer and removed the output side connection from Neutral to Earth ground the unit performed as you would expect. The medical use was not to provide isolation as you would expect in a test environment but to stop GFCI circuits from tripping due to the high capacitance from Line to Neutral which is due to the differential mode noise filtering in the medical equipment.
      Larry

    • @stevekean512
      @stevekean512 9 месяцев назад

      Good investigation. I'm not working on high voltages much, but, ground faults are still able to fry equipment and blow probes. Will follow you now. I am looking for a good bench isolation transformer in Austin, Tx.