    @bryanswanson5007 10 лет назад +2

    you need to contact your local heating company. The flames should be all blue with no yellow tips. That is a sign of incomplete combustion and could potentially create a hazardous condition. Seriously

  • @confidentlocal8600
    @confidentlocal8600 9 лет назад +1

    Flames dancing when blower turns on == probably a cracked heat exchanger.

  • @Samthe17
    @Samthe17 3 года назад

    Show us the condenser. What is it?

  • @leonardlee8916
    @leonardlee8916 8 лет назад +1

    is that belt driven?

  • @sircovfefe8858
    @sircovfefe8858 6 лет назад

    where is the air filter located on these? i cant find mine

    • @krysziolkowski1262
      @krysziolkowski1262 5 лет назад

      Up on top behind the exhaust pipe. Real pain in the butt to get too. remove the panel behind the exhaust pipe.

    • @sircovfefe8858
      @sircovfefe8858 5 лет назад

      @@krysziolkowski1262 I had found it, now trick is finding the proper filters, I've only found them online, not cheap

    • @DilanGilluly
      @DilanGilluly 5 лет назад

      You can also put a filter housing on the intake plenum, or have a contractor do it if you don't know how. My furnace took a specific size and the previous homeowners had a HVAC contractor put in a filter housing that takes a 16x24 which is a regular size. There's some up front cost but might be worth it if the filters are more than $20 each. I get decent 16x24 filters for about $2.79.

  • @5822huron
    @5822huron 2 года назад

    Lots of soot in this burners

  • @cristylea80
    @cristylea80 11 лет назад +1