  • @AustinH57
    @AustinH57 Год назад +1

    Would that added cab angle during the first horizontal calibration make the body sensor inaccurate at all? Or is this cal just between the boom and stick sensors?

    • @4kequipment88
      @4kequipment88  Год назад +1

      Each section for the calibration only does certain sensor(s) at a time. The 2D Sensor (or body sensor) has an independent calibration that can be done or redone anytime in the settings.

    • @AustinH57
      @AustinH57 Год назад

      Awesome, thank you